2017-04-02 16:48:26 +00:00
/**
* Marlin 3 D Printer Firmware
* Copyright ( C ) 2016 MarlinFirmware [ https : //github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl .
* Copyright ( C ) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software : you can redistribute it and / or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation , either version 3 of the License , or
* ( at your option ) any later version .
*
* This program is distributed in the hope that it will be useful ,
* but WITHOUT ANY WARRANTY ; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE . See the
* GNU General Public License for more details .
*
* You should have received a copy of the GNU General Public License
* along with this program . If not , see < http : //www.gnu.org/licenses/>.
*
*/
# include "MarlinConfig.h"
# if ENABLED(AUTO_BED_LEVELING_UBL)
//#include "vector_3.h"
//#include "qr_solve.h"
2017-04-06 00:25:36 +00:00
# include "ubl.h"
2017-04-02 16:48:26 +00:00
# include "Marlin.h"
# include "hex_print_routines.h"
# include "configuration_store.h"
# include "planner.h"
# include "ultralcd.h"
# include <math.h>
void lcd_babystep_z ( ) ;
void lcd_return_to_status ( ) ;
bool lcd_clicked ( ) ;
void lcd_implementation_clear ( ) ;
void lcd_mesh_edit_setup ( float initial ) ;
2017-04-08 08:16:13 +00:00
void tilt_mesh_based_on_probed_grid ( const bool ) ;
2017-04-02 16:48:26 +00:00
float lcd_mesh_edit ( ) ;
void lcd_z_offset_edit_setup ( float ) ;
float lcd_z_offset_edit ( ) ;
extern float meshedit_done ;
extern long babysteps_done ;
extern float code_value_float ( ) ;
extern bool code_value_bool ( ) ;
extern bool code_has_value ( ) ;
extern float probe_pt ( float x , float y , bool , int ) ;
extern bool set_probe_deployed ( bool ) ;
2017-04-08 08:16:13 +00:00
2017-04-02 16:48:26 +00:00
bool ProbeStay = true ;
constexpr float ubl_3_point_1_X = UBL_PROBE_PT_1_X ,
ubl_3_point_1_Y = UBL_PROBE_PT_1_Y ,
ubl_3_point_2_X = UBL_PROBE_PT_2_X ,
ubl_3_point_2_Y = UBL_PROBE_PT_2_Y ,
ubl_3_point_3_X = UBL_PROBE_PT_3_X ,
ubl_3_point_3_Y = UBL_PROBE_PT_3_Y ;
# define SIZE_OF_LITTLE_RAISE 0
# define BIG_RAISE_NOT_NEEDED 0
extern void lcd_quick_feedback ( ) ;
/**
* G29 : Unified Bed Leveling by Roxy
*
* Parameters understood by this leveling system :
*
* A Activate Activate the Unified Bed Leveling system .
*
* B # Business Use the ' Business Card ' mode of the Manual Probe subsystem . This is invoked as
* G29 P2 B The mode of G29 P2 allows you to use a bussiness card or recipe card
* as a shim that the nozzle will pinch as it is lowered . The idea is that you
* can easily feel the nozzle getting to the same height by the amount of resistance
* the business card exhibits to movement . You should try to achieve the same amount
* of resistance on each probed point to facilitate accurate and repeatable measurements .
* You should be very careful not to drive the nozzle into the bussiness card with a
* lot of force as it is very possible to cause damage to your printer if your are
* careless . If you use the B option with G29 P2 B you can leave the number parameter off
* on its first use to enable measurement of the business card thickness . Subsequent usage
* of the B parameter can have the number previously measured supplied to the command .
* Incidently , you are much better off using something like a Spark Gap feeler gauge than
* something that compresses like a Business Card .
*
* C Continue Continue , Constant , Current Location . This is not a primary command . C is used to
* further refine the behaviour of several other commands . Issuing a G29 P1 C will
* continue the generation of a partially constructed Mesh without invalidating what has
* been done . Issuing a G29 P2 C will tell the Manual Probe subsystem to use the current
* location in its search for the closest unmeasured Mesh Point . When used with a G29 Z C
* it indicates to use the current location instead of defaulting to the center of the print bed .
*
* D Disable Disable the Unified Bed Leveling system .
*
* E Stow_probe Stow the probe after each sampled point .
*
* F # Fade * Fade the amount of Mesh Based Compensation over a specified height . At the
* specified height , no correction is applied and natural printer kenimatics take over . If no
* number is specified for the command , 10 mm is assumed to be reasonable .
*
* G # Grid * Perform a Grid Based Leveling of the current Mesh using a grid with n points on a side .
*
* H # Height Specify the Height to raise the nozzle after each manual probe of the bed . The
* default is 5 mm .
*
* I # Invalidate Invalidate specified number of Mesh Points . The nozzle location is used unless
* the X and Y parameter are used . If no number is specified , only the closest Mesh
* point to the location is invalidated . The M parameter is available as well to produce
* a map after the operation . This command is useful to invalidate a portion of the
* Mesh so it can be adjusted using other tools in the Unified Bed Leveling System . When
* attempting to invalidate an isolated bad point in the mesh , the M option will indicate
* where the nozzle is positioned in the Mesh with ( # ) . You can move the nozzle around on
* the bed and use this feature to select the center of the area ( or cell ) you want to
* invalidate .
*
* K # Kompare Kompare current Mesh with stored Mesh # replacing current Mesh with the result . This
* command literally performs a diff between two Meshes .
*
* L Load * Load Mesh from the previously activated location in the EEPROM .
*
* L # Load * Load Mesh from the specified location in the EEPROM . Set this location as activated
* for subsequent Load and Store operations .
*
* O Map * Display the Mesh Map Topology .
* The parameter can be specified alone ( ie . G29 O ) or in combination with many of the
* other commands . The Mesh Map option works with all of the Phase
* commands ( ie . G29 P4 R 5 X 50 Y100 C - .1 O ) The Map parameter can also of a Map Type
* specified . A map type of 0 is the default is user readable . A map type of 1 can
* be specified and is suitable to Cut & Paste into Excel to allow graphing of the user ' s
* mesh .
*
* N No Home G29 normally insists that a G28 has been performed . You can over rule this with an
* N option . In general , you should not do this . This can only be done safely with
* commands that do not move the nozzle .
*
* The P or Phase commands are used for the bulk of the work to setup a Mesh . In general , your Mesh will
* start off being initialized with a G29 P0 or a G29 P1 . Further refinement of the Mesh happens with
* each additional Phase that processes it .
*
* P0 Phase 0 Zero Mesh Data and turn off the Mesh Compensation System . This reverts the
* 3 D Printer to the same state it was in before the Unified Bed Leveling Compensation
* was turned on . Setting the entire Mesh to Zero is a special case that allows
* a subsequent G or T leveling operation for backward compatibility .
*
* P1 Phase 1 Invalidate entire Mesh and continue with automatic generation of the Mesh data using
* the Z - Probe . Depending upon the values of DELTA_PROBEABLE_RADIUS and
* DELTA_PRINTABLE_RADIUS some area of the bed will not have Mesh Data automatically
* generated . This will be handled in Phase 2. If the Phase 1 command is given the
* C ( Continue ) parameter it does not invalidate the Mesh prior to automatically
* probing needed locations . This allows you to invalidate portions of the Mesh but still
* use the automatic probing capabilities of the Unified Bed Leveling System . An X and Y
* parameter can be given to prioritize where the command should be trying to measure points .
* If the X and Y parameters are not specified the current probe position is used . Phase 1
* allows you to specify the M ( Map ) parameter so you can watch the generation of the Mesh .
* Phase 1 also watches for the LCD Panel ' s Encoder Switch being held in a depressed state .
* It will suspend generation of the Mesh if it sees the user request that . ( This check is
* only done between probe points . You will need to press and hold the switch until the
* Phase 1 command can detect it . )
*
* P2 Phase 2 Probe areas of the Mesh that can ' t be automatically handled . Phase 2 respects an H
* parameter to control the height between Mesh points . The default height for movement
* between Mesh points is 5 mm . A smaller number can be used to make this part of the
* calibration less time consuming . You will be running the nozzle down until it just barely
* touches the glass . You should have the nozzle clean with no plastic obstructing your view .
* Use caution and move slowly . It is possible to damage your printer if you are careless .
* Note that this command will use the configuration # define SIZE_OF_LITTLE_RAISE if the
* nozzle is moving a distance of less than BIG_RAISE_NOT_NEEDED .
*
* The H parameter can be set negative if your Mesh dips in a large area . You can press
* and hold the LCD Panel ' s encoder wheel to terminate the current Phase 2 command . You
* can then re - issue the G29 P 2 command with an H parameter that is more suitable for the
* area you are manually probing . Note that the command tries to start you in a corner
* of the bed where movement will be predictable . You can force the location to be used in
* the distance calculations by using the X and Y parameters . You may find it is helpful to
2017-04-08 08:16:13 +00:00
* print out a Mesh Map ( G29 O ) to understand where the mesh is invalidated and where
2017-04-02 16:48:26 +00:00
* the nozzle will need to move in order to complete the command . The C parameter is
* available on the Phase 2 command also and indicates the search for points to measure should
* be done based on the current location of the nozzle .
*
* A B parameter is also available for this command and described up above . It places the
* manual probe subsystem into Business Card mode where the thickness of a business care is
* measured and then used to accurately set the nozzle height in all manual probing for the
* duration of the command . ( S for Shim mode would be a better parameter name , but S is needed
* for Save or Store of the Mesh to EEPROM ) A Business card can be used , but you will have
* better results if you use a flexible Shim that does not compress very much . That makes it
* easier for you to get the nozzle to press with similar amounts of force against the shim so you
* can get accurate measurements . As you are starting to touch the nozzle against the shim try
* to get it to grasp the shim with the same force as when you measured the thickness of the
* shim at the start of the command .
*
* Phase 2 allows the O ( Map ) parameter to be specified . This helps the user see the progression
* of the Mesh being built .
*
* P3 Phase 3 Fill the unpopulated regions of the Mesh with a fixed value . The C parameter is
* used to specify the ' constant ' value to fill all invalid areas of the Mesh . If no C parameter
* is specified , a value of 0.0 is assumed . The R parameter can be given to specify the number
* of points to set . If the R parameter is specified the current nozzle position is used to
* find the closest points to alter unless the X and Y parameter are used to specify the fill
* location .
*
* P4 Phase 4 Fine tune the Mesh . The Delta Mesh Compensation System assume the existance of
* an LCD Panel . It is possible to fine tune the mesh without the use of an LCD Panel .
* ( More work and details on doing this later ! )
* The System will search for the closest Mesh Point to the nozzle . It will move the
* nozzle to this location . The user can use the LCD Panel to carefully adjust the nozzle
* so it is just barely touching the bed . When the user clicks the control , the System
* will lock in that height for that point in the Mesh Compensation System .
*
* Phase 4 has several additional parameters that the user may find helpful . Phase 4
* can be started at a specific location by specifying an X and Y parameter . Phase 4
* can be requested to continue the adjustment of Mesh Points by using the R ( epeat )
* parameter . If the Repetition count is not specified , it is assumed the user wishes
* to adjust the entire matrix . The nozzle is moved to the Mesh Point being edited .
* The command can be terminated early ( or after the area of interest has been edited ) by
* pressing and holding the encoder wheel until the system recognizes the exit request .
* Phase 4 ' s general form is G29 P4 [ R # of points ] [ X position ] [ Y position ]
*
* Phase 4 is intended to be used with the G26 Mesh Validation Command . Using the
* information left on the printer ' s bed from the G26 command it is very straight forward
* and easy to fine tune the Mesh . One concept that is important to remember and that
* will make using the Phase 4 command easy to use is this : You are editing the Mesh Points .
* If you have too little clearance and not much plastic was extruded in an area , you want to
* LOWER the Mesh Point at the location . If you did not get good adheasion , you want to
* RAISE the Mesh Point at that location .
*
*
* P5 Phase 5 Find Mean Mesh Height and Standard Deviation . Typically , it is easier to use and
* work with the Mesh if it is Mean Adjusted . You can specify a C parameter to
* Correct the Mesh to a 0.00 Mean Height . Adding a C parameter will automatically
* execute a G29 P6 C < mean height > .
*
* P6 Phase 6 Shift Mesh height . The entire Mesh ' s height is adjusted by the height specified
* with the C parameter . Being able to adjust the height of a Mesh is useful tool . It
* can be used to compensate for poorly calibrated Z - Probes and other errors . Ideally ,
* you should have the Mesh adjusted for a Mean Height of 0.00 and the Z - Probe measuring
* 0.000 at the Z Home location .
*
* Q Test * Load specified Test Pattern to assist in checking correct operation of system . This
* command is not anticipated to be of much value to the typical user . It is intended
* for developers to help them verify correct operation of the Unified Bed Leveling System .
*
* S Store Store the current Mesh in the Activated area of the EEPROM . It will also store the
* current state of the Unified Bed Leveling system in the EEPROM .
*
* S # Store Store the current Mesh at the specified location in EEPROM . Activate this location
* for subsequent Load and Store operations . It will also store the current state of
* the Unified Bed Leveling system in the EEPROM .
*
* S - 1 Store Store the current Mesh as a print out that is suitable to be feed back into
* the system at a later date . The text generated can be saved and later sent by PronterFace or
* Repetier Host to reconstruct the current mesh on another machine .
*
* T 3 - Point Perform a 3 Point Bed Leveling on the current Mesh
*
* U Unlevel Perform a probe of the outer perimeter to assist in physically leveling unlevel beds .
* Only used for G29 P1 O U It will speed up the probing of the edge of the bed . This
* is useful when the entire bed does not need to be probed because it will be adjusted .
*
* W What ? Display valuable data the Unified Bed Leveling System knows .
*
* X # * * X Location for this line of commands
*
* Y # * * Y Location for this line of commands
*
* Z Zero * Probes to set the Z Height of the nozzle . The entire Mesh can be raised or lowered
* by just doing a G29 Z
*
* Z # Zero * The entire Mesh can be raised or lowered to conform with the specified difference .
* zprobe_zoffset is added to the calculation .
*
*
* Release Notes :
* You MUST do M502 , M500 to initialize the storage . Failure to do this will cause all
* kinds of problems . Enabling EEPROM Storage is highly recommended . With EEPROM Storage
* of the mesh , you are limited to 3 - Point and Grid Leveling . ( G29 P0 T and G29 P0 G
* respectively . )
*
* When you do a G28 and then a G29 P1 to automatically build your first mesh , you are going to notice
* the Unified Bed Leveling probes points further and further away from the starting location . ( The
* starting location defaults to the center of the bed . ) The original Grid and Mesh leveling used
* a Zig Zag pattern . The new pattern is better , especially for people with Delta printers . This
* allows you to get the center area of the Mesh populated ( and edited ) quicker . This allows you to
* perform a small print and check out your settings quicker . You do not need to populate the
* entire mesh to use it . ( You don ' t want to spend a lot of time generating a mesh only to realize
* you don ' t have the resolution or zprobe_zoffset set correctly . The Mesh generation
* gathers points closest to where the nozzle is located unless you specify an ( X , Y ) coordinate pair .
*
* The Unified Bed Leveling uses a lot of EEPROM storage to hold its data . And it takes some effort
* to get this Mesh data correct for a user ' s printer . We do not want this data destroyed as
* new versions of Marlin add or subtract to the items stored in EEPROM . So , for the benefit of
* the users , we store the Mesh data at the end of the EEPROM and do not keep it contiguous with the
* other data stored in the EEPROM . ( For sure the developers are going to complain about this , but
* this is going to be helpful to the users ! )
*
* The foundation of this Bed Leveling System is built on Epatel ' s Mesh Bed Leveling code . A big
* ' Thanks ! ' to him and the creators of 3 - Point and Grid Based leveling . Combining their contributions
* we now have the functionality and features of all three systems combined .
*/
// The simple parameter flags and values are 'static' so parameter parsing can be in a support routine.
static int g29_verbose_level , phase_value = - 1 , repetition_cnt ,
2017-04-06 23:46:47 +00:00
storage_slot = 0 , map_type , grid_size_G ; //unlevel_value = -1;
2017-04-02 16:48:26 +00:00
static bool repeat_flag , c_flag , x_flag , y_flag ;
static float x_pos , y_pos , measured_z , card_thickness = 0.0 , ubl_constant = 0.0 ;
# if ENABLED(ULTRA_LCD)
extern void lcd_setstatus ( const char * message , const bool persist ) ;
extern void lcd_setstatuspgm ( const char * message , const uint8_t level ) ;
# endif
void gcode_G29 ( ) {
SERIAL_PROTOCOLLNPAIR ( " ubl.eeprom_start= " , ubl . eeprom_start ) ;
if ( ubl . eeprom_start < 0 ) {
SERIAL_PROTOCOLLNPGM ( " ?You need to enable your EEPROM and initialize it " ) ;
SERIAL_PROTOCOLLNPGM ( " with M502, M500, M501 in that order. \n " ) ;
return ;
}
if ( ! code_seen ( ' N ' ) & & axis_unhomed_error ( true , true , true ) ) // Don't allow auto-leveling without homing first
gcode_G28 ( ) ;
if ( g29_parameter_parsing ( ) ) return ; // abort if parsing the simple parameters causes a problem,
// Invalidate Mesh Points. This command is a little bit asymetrical because
// it directly specifies the repetition count and does not use the 'R' parameter.
if ( code_seen ( ' I ' ) ) {
2017-04-02 21:13:15 +00:00
int cnt = 0 ;
2017-04-02 16:48:26 +00:00
repetition_cnt = code_has_value ( ) ? code_value_int ( ) : 1 ;
while ( repetition_cnt - - ) {
2017-04-02 21:13:15 +00:00
if ( cnt > 20 ) {
cnt = 0 ;
idle ( ) ;
}
2017-04-02 16:48:26 +00:00
const mesh_index_pair location = find_closest_mesh_point_of_type ( REAL , x_pos , y_pos , 0 , NULL , false ) ; // The '0' says we want to use the nozzle's position
if ( location . x_index < 0 ) {
SERIAL_PROTOCOLLNPGM ( " Entire Mesh invalidated. \n " ) ;
break ; // No more invalid Mesh Points to populate
}
ubl . z_values [ location . x_index ] [ location . y_index ] = NAN ;
}
SERIAL_PROTOCOLLNPGM ( " Locations invalidated. \n " ) ;
}
if ( code_seen ( ' Q ' ) ) {
const int test_pattern = code_has_value ( ) ? code_value_int ( ) : - 1 ;
if ( ! WITHIN ( test_pattern , 0 , 2 ) ) {
SERIAL_PROTOCOLLNPGM ( " Invalid test_pattern value. (0-2) \n " ) ;
return ;
}
SERIAL_PROTOCOLLNPGM ( " Loading test_pattern values. \n " ) ;
switch ( test_pattern ) {
case 0 :
2017-04-06 03:29:44 +00:00
for ( uint8_t x = 0 ; x < GRID_MAX_POINTS_X ; x + + ) { // Create a bowl shape - similar to
for ( uint8_t y = 0 ; y < GRID_MAX_POINTS_Y ; y + + ) { // a poorly calibrated Delta.
const float p1 = 0.5 * ( GRID_MAX_POINTS_X ) - x ,
p2 = 0.5 * ( GRID_MAX_POINTS_Y ) - y ;
2017-04-02 16:48:26 +00:00
ubl . z_values [ x ] [ y ] + = 2.0 * HYPOT ( p1 , p2 ) ;
}
}
break ;
case 1 :
2017-04-06 03:29:44 +00:00
for ( uint8_t x = 0 ; x < GRID_MAX_POINTS_X ; x + + ) { // Create a diagonal line several Mesh cells thick that is raised
2017-04-02 16:48:26 +00:00
ubl . z_values [ x ] [ x ] + = 9.999 ;
2017-04-06 03:29:44 +00:00
ubl . z_values [ x ] [ x + ( x < GRID_MAX_POINTS_Y - 1 ) ? 1 : - 1 ] + = 9.999 ; // We want the altered line several mesh points thick
2017-04-02 16:48:26 +00:00
}
break ;
case 2 :
// Allow the user to specify the height because 10mm is a little extreme in some cases.
2017-04-06 03:29:44 +00:00
for ( uint8_t x = ( GRID_MAX_POINTS_X ) / 3 ; x < 2 * ( GRID_MAX_POINTS_X ) / 3 ; x + + ) // Create a rectangular raised area in
for ( uint8_t y = ( GRID_MAX_POINTS_Y ) / 3 ; y < 2 * ( GRID_MAX_POINTS_Y ) / 3 ; y + + ) // the center of the bed
2017-04-02 16:48:26 +00:00
ubl . z_values [ x ] [ y ] + = code_seen ( ' C ' ) ? ubl_constant : 9.99 ;
break ;
}
}
/*
if ( code_seen ( ' U ' ) ) {
unlevel_value = code_value_int ( ) ;
//if (!WITHIN(unlevel_value, 0, 7)) {
// SERIAL_PROTOCOLLNPGM("Invalid Unlevel value. (0-4)\n");
// return;
//}
}
2017-04-06 23:46:47 +00:00
*/
if ( code_seen ( ' G ' ) ) {
uint8_t grid_size_G = code_has_value ( ) ? code_value_int ( ) : 3 ;
if ( grid_size_G < 2 ) {
SERIAL_PROTOCOLLNPGM ( " ERROR - grid size must be 2 or more " ) ;
return ;
}
2017-04-08 08:16:13 +00:00
if ( grid_size_G > GRID_MAX_POINTS_X | | grid_size_G > GRID_MAX_POINTS_Y ) {
2017-04-06 23:46:47 +00:00
SERIAL_PROTOCOLLNPGM ( " ERROR - grid size can NOT exceed GRID_MAX_POINTS_X nor GRID_MAX_POINTS_Y " ) ;
return ;
}
2017-04-08 08:16:13 +00:00
tilt_mesh_based_on_probed_grid ( code_seen ( ' O ' ) | | code_seen ( ' M ' ) ) ;
2017-04-06 23:46:47 +00:00
}
2017-04-02 16:48:26 +00:00
if ( code_seen ( ' P ' ) ) {
phase_value = code_value_int ( ) ;
if ( ! WITHIN ( phase_value , 0 , 7 ) ) {
SERIAL_PROTOCOLLNPGM ( " Invalid Phase value. (0-4) \n " ) ;
return ;
}
switch ( phase_value ) {
case 0 :
//
// Zero Mesh Data
//
ubl . reset ( ) ;
SERIAL_PROTOCOLLNPGM ( " Mesh zeroed. \n " ) ;
break ;
case 1 :
//
// Invalidate Entire Mesh and Automatically Probe Mesh in areas that can be reached by the probe
//
2017-04-08 08:16:13 +00:00
if ( ! code_seen ( ' C ' ) ) {
2017-04-02 16:48:26 +00:00
ubl . invalidate ( ) ;
SERIAL_PROTOCOLLNPGM ( " Mesh invalidated. Probing mesh. \n " ) ;
}
if ( g29_verbose_level > 1 ) {
2017-04-08 08:16:13 +00:00
SERIAL_PROTOCOLPAIR ( " Probing Mesh Points Closest to ( " , x_pos ) ;
SERIAL_PROTOCOLCHAR ( ' , ' ) ;
SERIAL_PROTOCOL ( y_pos ) ;
2017-04-02 16:48:26 +00:00
SERIAL_PROTOCOLLNPGM ( " ) \n " ) ;
}
probe_entire_mesh ( x_pos + X_PROBE_OFFSET_FROM_EXTRUDER , y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER ,
code_seen ( ' O ' ) | | code_seen ( ' M ' ) , code_seen ( ' E ' ) , code_seen ( ' U ' ) ) ;
break ;
case 2 : {
//
// Manually Probe Mesh in areas that can't be reached by the probe
//
SERIAL_PROTOCOLLNPGM ( " Manually probing unreachable mesh locations. \n " ) ;
do_blocking_move_to_z ( Z_CLEARANCE_BETWEEN_PROBES ) ;
if ( ! x_flag & & ! y_flag ) { // use a good default location for the path
2017-04-08 08:16:13 +00:00
// The flipped > and < operators on these two comparisons is
// intentional. It should cause the probed points to follow a
// nice path on Cartesian printers. It may make sense to
// have Delta printers default to the center of the bed.
// For now, until that is decided, it can be forced with the X
// and Y parameters.
x_pos = X_PROBE_OFFSET_FROM_EXTRUDER > 0 ? X_MAX_POS : X_MIN_POS ;
y_pos = Y_PROBE_OFFSET_FROM_EXTRUDER < 0 ? Y_MAX_POS : Y_MIN_POS ;
}
2017-04-02 16:48:26 +00:00
if ( code_seen ( ' C ' ) ) {
x_pos = current_position [ X_AXIS ] ;
y_pos = current_position [ Y_AXIS ] ;
}
const float height = code_seen ( ' H ' ) & & code_has_value ( ) ? code_value_float ( ) : Z_CLEARANCE_BETWEEN_PROBES ;
if ( code_seen ( ' B ' ) ) {
card_thickness = code_has_value ( ) ? code_value_float ( ) : measure_business_card_thickness ( height ) ;
if ( fabs ( card_thickness ) > 1.5 ) {
SERIAL_PROTOCOLLNPGM ( " ?Error in Business Card measurement. \n " ) ;
return ;
}
}
manually_probe_remaining_mesh ( x_pos , y_pos , height , card_thickness , code_seen ( ' O ' ) | | code_seen ( ' M ' ) ) ;
} break ;
case 3 : {
//
// Populate invalid Mesh areas with a constant
//
const float height = code_seen ( ' C ' ) ? ubl_constant : 0.0 ;
// If no repetition is specified, do the whole Mesh
if ( ! repeat_flag ) repetition_cnt = 9999 ;
while ( repetition_cnt - - ) {
const mesh_index_pair location = find_closest_mesh_point_of_type ( INVALID , x_pos , y_pos , 0 , NULL , false ) ; // The '0' says we want to use the nozzle's position
if ( location . x_index < 0 ) break ; // No more invalid Mesh Points to populate
ubl . z_values [ location . x_index ] [ location . y_index ] = height ;
}
} break ;
case 4 :
//
// Fine Tune (i.e., Edit) the Mesh
//
fine_tune_mesh ( x_pos , y_pos , code_seen ( ' O ' ) | | code_seen ( ' M ' ) ) ;
break ;
case 5 :
find_mean_mesh_height ( ) ;
break ;
case 6 :
shift_mesh_height ( ) ;
break ;
case 10 :
// [DEBUG] Pay no attention to this stuff. It can be removed soon.
SERIAL_ECHO_START ;
SERIAL_ECHOLNPGM ( " Checking G29 has control of LCD Panel: " ) ;
KEEPALIVE_STATE ( PAUSED_FOR_USER ) ;
2017-04-06 23:46:47 +00:00
ubl . has_control_of_lcd_panel = true ;
2017-04-02 16:48:26 +00:00
while ( ! ubl_lcd_clicked ( ) ) {
safe_delay ( 250 ) ;
if ( ubl . encoder_diff ) {
SERIAL_ECHOLN ( ( int ) ubl . encoder_diff ) ;
ubl . encoder_diff = 0 ;
}
}
SERIAL_ECHOLNPGM ( " G29 giving back control of LCD Panel. " ) ;
ubl . has_control_of_lcd_panel = false ;
KEEPALIVE_STATE ( IN_HANDLER ) ;
break ;
case 11 :
// [DEBUG] wait_for_user code. Pay no attention to this stuff. It can be removed soon.
SERIAL_ECHO_START ;
SERIAL_ECHOLNPGM ( " Checking G29 has control of LCD Panel: " ) ;
KEEPALIVE_STATE ( PAUSED_FOR_USER ) ;
wait_for_user = true ;
while ( wait_for_user ) {
safe_delay ( 250 ) ;
if ( ubl . encoder_diff ) {
SERIAL_ECHOLN ( ( int ) ubl . encoder_diff ) ;
ubl . encoder_diff = 0 ;
}
}
SERIAL_ECHOLNPGM ( " G29 giving back control of LCD Panel. " ) ;
KEEPALIVE_STATE ( IN_HANDLER ) ;
break ;
}
}
if ( code_seen ( ' T ' ) ) {
const float lx1 = LOGICAL_X_POSITION ( ubl_3_point_1_X ) ,
lx2 = LOGICAL_X_POSITION ( ubl_3_point_2_X ) ,
lx3 = LOGICAL_X_POSITION ( ubl_3_point_3_X ) ,
ly1 = LOGICAL_Y_POSITION ( ubl_3_point_1_Y ) ,
ly2 = LOGICAL_Y_POSITION ( ubl_3_point_2_Y ) ,
ly3 = LOGICAL_Y_POSITION ( ubl_3_point_3_Y ) ;
float z1 = probe_pt ( lx1 , ly1 , false /*Stow Flag*/ , g29_verbose_level ) ,
z2 = probe_pt ( lx2 , ly2 , false /*Stow Flag*/ , g29_verbose_level ) ,
z3 = probe_pt ( lx3 , ly3 , true /*Stow Flag*/ , g29_verbose_level ) ;
// We need to adjust z1, z2, z3 by the Mesh Height at these points. Just because they are non-zero doesn't mean
// the Mesh is tilted! (We need to compensate each probe point by what the Mesh says that location's height is)
z1 - = ubl . get_z_correction ( lx1 , ly1 ) ;
z2 - = ubl . get_z_correction ( lx2 , ly2 ) ;
z3 - = ubl . get_z_correction ( lx3 , ly3 ) ;
do_blocking_move_to_xy ( ( X_MAX_POS - ( X_MIN_POS ) ) / 2.0 , ( Y_MAX_POS - ( Y_MIN_POS ) ) / 2.0 ) ;
tilt_mesh_based_on_3pts ( z1 , z2 , z3 ) ;
}
//
// Much of the 'What?' command can be eliminated. But until we are fully debugged, it is
// good to have the extra information. Soon... we prune this to just a few items
//
if ( code_seen ( ' W ' ) ) g29_what_command ( ) ;
//
// When we are fully debugged, the EEPROM dump command will get deleted also. But
// right now, it is good to have the extra information. Soon... we prune this.
//
if ( code_seen ( ' J ' ) ) g29_eeprom_dump ( ) ; // EEPROM Dump
//
// When we are fully debugged, this may go away. But there are some valid
// use cases for the users. So we can wait and see what to do with it.
//
if ( code_seen ( ' K ' ) ) // Kompare Current Mesh Data to Specified Stored Mesh
g29_compare_current_mesh_to_stored_mesh ( ) ;
//
// Load a Mesh from the EEPROM
//
if ( code_seen ( ' L ' ) ) { // Load Current Mesh Data
storage_slot = code_has_value ( ) ? code_value_int ( ) : ubl . state . eeprom_storage_slot ;
const int16_t j = ( UBL_LAST_EEPROM_INDEX - ubl . eeprom_start ) / sizeof ( ubl . z_values ) ;
if ( ! WITHIN ( storage_slot , 0 , j - 1 ) | | ubl . eeprom_start < = 0 ) {
SERIAL_PROTOCOLLNPGM ( " ?EEPROM storage not available for use. \n " ) ;
return ;
}
ubl . load_mesh ( storage_slot ) ;
ubl . state . eeprom_storage_slot = storage_slot ;
if ( storage_slot ! = ubl . state . eeprom_storage_slot )
ubl . store_state ( ) ;
SERIAL_PROTOCOLLNPGM ( " Done. \n " ) ;
}
//
// Store a Mesh in the EEPROM
//
if ( code_seen ( ' S ' ) ) { // Store (or Save) Current Mesh Data
storage_slot = code_has_value ( ) ? code_value_int ( ) : ubl . state . eeprom_storage_slot ;
if ( storage_slot = = - 1 ) { // Special case, we are going to 'Export' the mesh to the
SERIAL_ECHOLNPGM ( " G29 I 999 " ) ; // host in a form it can be reconstructed on a different machine
2017-04-06 03:29:44 +00:00
for ( uint8_t x = 0 ; x < GRID_MAX_POINTS_X ; x + + )
for ( uint8_t y = 0 ; y < GRID_MAX_POINTS_Y ; y + + )
2017-04-02 16:48:26 +00:00
if ( ! isnan ( ubl . z_values [ x ] [ y ] ) ) {
SERIAL_ECHOPAIR ( " M421 I " , x ) ;
SERIAL_ECHOPAIR ( " J " , y ) ;
SERIAL_ECHOPGM ( " Z " ) ;
SERIAL_ECHO_F ( ubl . z_values [ x ] [ y ] , 6 ) ;
SERIAL_EOL ;
}
return ;
}
const int16_t j = ( UBL_LAST_EEPROM_INDEX - ubl . eeprom_start ) / sizeof ( ubl . z_values ) ;
if ( ! WITHIN ( storage_slot , 0 , j - 1 ) | | ubl . eeprom_start < = 0 ) {
SERIAL_PROTOCOLLNPGM ( " ?EEPROM storage not available for use. \n " ) ;
SERIAL_PROTOCOLLNPAIR ( " ?Use 0 to " , j - 1 ) ;
goto LEAVE ;
}
ubl . store_mesh ( storage_slot ) ;
ubl . state . eeprom_storage_slot = storage_slot ;
//
// if (storage_slot != ubl.state.eeprom_storage_slot)
ubl . store_state ( ) ; // Always save an updated copy of the UBL State info
SERIAL_PROTOCOLLNPGM ( " Done. \n " ) ;
}
if ( code_seen ( ' O ' ) | | code_seen ( ' M ' ) )
ubl . display_map ( code_has_value ( ) ? code_value_int ( ) : 0 ) ;
if ( code_seen ( ' Z ' ) ) {
if ( code_has_value ( ) )
ubl . state . z_offset = code_value_float ( ) ; // do the simple case. Just lock in the specified value
else {
save_ubl_active_state_and_disable ( ) ;
//measured_z = probe_pt(x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, ProbeDeployAndStow, g29_verbose_level);
2017-04-06 23:46:47 +00:00
ubl . has_control_of_lcd_panel = true ; // Grab the LCD Hardware
2017-04-02 16:48:26 +00:00
measured_z = 1.5 ;
do_blocking_move_to_z ( measured_z ) ; // Get close to the bed, but leave some space so we don't damage anything
// The user is not going to be locking in a new Z-Offset very often so
// it won't be that painful to spin the Encoder Wheel for 1.5mm
lcd_implementation_clear ( ) ;
lcd_z_offset_edit_setup ( measured_z ) ;
KEEPALIVE_STATE ( PAUSED_FOR_USER ) ;
do {
measured_z = lcd_z_offset_edit ( ) ;
idle ( ) ;
do_blocking_move_to_z ( measured_z ) ;
} while ( ! ubl_lcd_clicked ( ) ) ;
2017-04-06 23:46:47 +00:00
ubl . has_control_of_lcd_panel = true ; // There is a race condition for the Encoder Wheel getting clicked.
2017-04-02 16:48:26 +00:00
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune)
// or here. So, until we are done looking for a long Encoder Wheel Press,
// we need to take control of the panel
KEEPALIVE_STATE ( IN_HANDLER ) ;
lcd_return_to_status ( ) ;
const millis_t nxt = millis ( ) + 1500UL ;
while ( ubl_lcd_clicked ( ) ) { // debounce and watch for abort
idle ( ) ;
if ( ELAPSED ( millis ( ) , nxt ) ) {
SERIAL_PROTOCOLLNPGM ( " \n Z-Offset Adjustment Stopped. " ) ;
do_blocking_move_to_z ( Z_CLEARANCE_DEPLOY_PROBE ) ;
2017-04-08 08:16:13 +00:00
lcd_setstatuspgm ( PSTR ( " Z-Offset Stopped " ) ) ;
2017-04-02 16:48:26 +00:00
restore_ubl_active_state_and_leave ( ) ;
goto LEAVE ;
}
}
ubl . has_control_of_lcd_panel = false ;
safe_delay ( 20 ) ; // We don't want any switch noise.
ubl . state . z_offset = measured_z ;
lcd_implementation_clear ( ) ;
restore_ubl_active_state_and_leave ( ) ;
}
}
LEAVE :
# if ENABLED(ULTRA_LCD)
lcd_reset_alert_level ( ) ;
2017-04-08 08:16:13 +00:00
lcd_setstatuspgm ( PSTR ( " " ) ) ;
2017-04-02 16:48:26 +00:00
lcd_quick_feedback ( ) ;
# endif
ubl . has_control_of_lcd_panel = false ;
}
void find_mean_mesh_height ( ) {
uint8_t x , y ;
int n ;
float sum , sum_of_diff_squared , sigma , difference , mean ;
sum = sum_of_diff_squared = 0.0 ;
n = 0 ;
2017-04-06 03:29:44 +00:00
for ( x = 0 ; x < GRID_MAX_POINTS_X ; x + + )
for ( y = 0 ; y < GRID_MAX_POINTS_Y ; y + + )
2017-04-02 16:48:26 +00:00
if ( ! isnan ( ubl . z_values [ x ] [ y ] ) ) {
sum + = ubl . z_values [ x ] [ y ] ;
n + + ;
}
mean = sum / n ;
//
// Now do the sumation of the squares of difference from mean
//
2017-04-06 03:29:44 +00:00
for ( x = 0 ; x < GRID_MAX_POINTS_X ; x + + )
for ( y = 0 ; y < GRID_MAX_POINTS_Y ; y + + )
2017-04-02 16:48:26 +00:00
if ( ! isnan ( ubl . z_values [ x ] [ y ] ) ) {
difference = ( ubl . z_values [ x ] [ y ] - mean ) ;
sum_of_diff_squared + = difference * difference ;
}
SERIAL_ECHOLNPAIR ( " # of samples: " , n ) ;
SERIAL_ECHOPGM ( " Mean Mesh Height: " ) ;
SERIAL_ECHO_F ( mean , 6 ) ;
SERIAL_EOL ;
sigma = sqrt ( sum_of_diff_squared / ( n + 1 ) ) ;
SERIAL_ECHOPGM ( " Standard Deviation: " ) ;
SERIAL_ECHO_F ( sigma , 6 ) ;
SERIAL_EOL ;
if ( c_flag )
2017-04-06 03:29:44 +00:00
for ( x = 0 ; x < GRID_MAX_POINTS_X ; x + + )
for ( y = 0 ; y < GRID_MAX_POINTS_Y ; y + + )
2017-04-02 16:48:26 +00:00
if ( ! isnan ( ubl . z_values [ x ] [ y ] ) )
ubl . z_values [ x ] [ y ] - = mean + ubl_constant ;
}
void shift_mesh_height ( ) {
2017-04-06 03:29:44 +00:00
for ( uint8_t x = 0 ; x < GRID_MAX_POINTS_X ; x + + )
for ( uint8_t y = 0 ; y < GRID_MAX_POINTS_Y ; y + + )
2017-04-02 16:48:26 +00:00
if ( ! isnan ( ubl . z_values [ x ] [ y ] ) )
ubl . z_values [ x ] [ y ] + = ubl_constant ;
}
/**
* Probe all invalidated locations of the mesh that can be reached by the probe .
* This attempts to fill in locations closest to the nozzle ' s start location first .
*/
void probe_entire_mesh ( const float & lx , const float & ly , const bool do_ubl_mesh_map , const bool stow_probe , bool do_furthest ) {
mesh_index_pair location ;
2017-04-06 23:46:47 +00:00
ubl . has_control_of_lcd_panel = true ;
2017-04-02 16:48:26 +00:00
save_ubl_active_state_and_disable ( ) ; // we don't do bed level correction because we want the raw data when we probe
DEPLOY_PROBE ( ) ;
do {
if ( ubl_lcd_clicked ( ) ) {
SERIAL_PROTOCOLLNPGM ( " \n Mesh only partially populated. \n " ) ;
lcd_quick_feedback ( ) ;
STOW_PROBE ( ) ;
while ( ubl_lcd_clicked ( ) ) idle ( ) ;
ubl . has_control_of_lcd_panel = false ;
restore_ubl_active_state_and_leave ( ) ;
safe_delay ( 50 ) ; // Debounce the Encoder wheel
return ;
}
2017-04-08 08:16:13 +00:00
location = find_closest_mesh_point_of_type ( INVALID , lx , ly , 1 , NULL , do_furthest ) ; // the '1' says we want the location to be relative to the probe
2017-04-02 16:48:26 +00:00
if ( location . x_index > = 0 & & location . y_index > = 0 ) {
const float rawx = ubl . mesh_index_to_xpos [ location . x_index ] ,
rawy = ubl . mesh_index_to_ypos [ location . y_index ] ;
// TODO: Change to use `position_is_reachable` (for SCARA-compatibility)
if ( ! WITHIN ( rawx , MIN_PROBE_X , MAX_PROBE_X ) | | ! WITHIN ( rawy , MIN_PROBE_Y , MAX_PROBE_Y ) ) {
SERIAL_ERROR_START ;
SERIAL_ERRORLNPGM ( " Attempt to probe off the bed. " ) ;
ubl . has_control_of_lcd_panel = false ;
goto LEAVE ;
}
const float measured_z = probe_pt ( LOGICAL_X_POSITION ( rawx ) , LOGICAL_Y_POSITION ( rawy ) , stow_probe , g29_verbose_level ) ;
ubl . z_values [ location . x_index ] [ location . y_index ] = measured_z ;
}
if ( do_ubl_mesh_map ) ubl . display_map ( map_type ) ;
} while ( location . x_index > = 0 & & location . y_index > = 0 ) ;
LEAVE :
STOW_PROBE ( ) ;
restore_ubl_active_state_and_leave ( ) ;
do_blocking_move_to_xy (
constrain ( lx - ( X_PROBE_OFFSET_FROM_EXTRUDER ) , X_MIN_POS , X_MAX_POS ) ,
constrain ( ly - ( Y_PROBE_OFFSET_FROM_EXTRUDER ) , Y_MIN_POS , Y_MAX_POS )
) ;
}
vector_3 tilt_mesh_based_on_3pts ( const float & z1 , const float & z2 , const float & z3 ) {
float c , d , t ;
int i , j ;
vector_3 v1 = vector_3 ( ( ubl_3_point_1_X - ubl_3_point_2_X ) ,
( ubl_3_point_1_Y - ubl_3_point_2_Y ) ,
( z1 - z2 ) ) ,
v2 = vector_3 ( ( ubl_3_point_3_X - ubl_3_point_2_X ) ,
( ubl_3_point_3_Y - ubl_3_point_2_Y ) ,
( z3 - z2 ) ) ,
normal = vector_3 : : cross ( v1 , v2 ) ;
// printf("[%f,%f,%f] ", normal.x, normal.y, normal.z);
/**
* This code does two things . This vector is normal to the tilted plane .
* However , we don ' t know its direction . We need it to point up . So if
* Z is negative , we need to invert the sign of all components of the vector
* We also need Z to be unity because we are going to be treating this triangle
* as the sin ( ) and cos ( ) of the bed ' s tilt
*/
const float inv_z = 1.0 / normal . z ;
normal . x * = inv_z ;
normal . y * = inv_z ;
normal . z = 1.0 ;
//
// All of 3 of these points should give us the same d constant
//
t = normal . x * ubl_3_point_1_X + normal . y * ubl_3_point_1_Y ;
d = t + normal . z * z1 ;
c = d - t ;
SERIAL_ECHOPGM ( " d from 1st point: " ) ;
SERIAL_ECHO_F ( d , 6 ) ;
SERIAL_ECHOPGM ( " c: " ) ;
SERIAL_ECHO_F ( c , 6 ) ;
SERIAL_EOL ;
t = normal . x * ubl_3_point_2_X + normal . y * ubl_3_point_2_Y ;
d = t + normal . z * z2 ;
c = d - t ;
SERIAL_ECHOPGM ( " d from 2nd point: " ) ;
SERIAL_ECHO_F ( d , 6 ) ;
SERIAL_ECHOPGM ( " c: " ) ;
SERIAL_ECHO_F ( c , 6 ) ;
SERIAL_EOL ;
t = normal . x * ubl_3_point_3_X + normal . y * ubl_3_point_3_Y ;
d = t + normal . z * z3 ;
c = d - t ;
SERIAL_ECHOPGM ( " d from 3rd point: " ) ;
SERIAL_ECHO_F ( d , 6 ) ;
SERIAL_ECHOPGM ( " c: " ) ;
SERIAL_ECHO_F ( c , 6 ) ;
SERIAL_EOL ;
2017-04-06 03:29:44 +00:00
for ( i = 0 ; i < GRID_MAX_POINTS_X ; i + + ) {
for ( j = 0 ; j < GRID_MAX_POINTS_Y ; j + + ) {
2017-04-02 16:48:26 +00:00
c = - ( ( normal . x * ( UBL_MESH_MIN_X + i * ( MESH_X_DIST ) ) + normal . y * ( UBL_MESH_MIN_Y + j * ( MESH_Y_DIST ) ) ) - d ) ;
ubl . z_values [ i ] [ j ] + = c ;
}
}
return normal ;
}
float use_encoder_wheel_to_measure_point ( ) {
KEEPALIVE_STATE ( PAUSED_FOR_USER ) ;
while ( ! ubl_lcd_clicked ( ) ) { // we need the loop to move the nozzle based on the encoder wheel here!
idle ( ) ;
if ( ubl . encoder_diff ) {
do_blocking_move_to_z ( current_position [ Z_AXIS ] + 0.01 * float ( ubl . encoder_diff ) ) ;
ubl . encoder_diff = 0 ;
}
}
KEEPALIVE_STATE ( IN_HANDLER ) ;
return current_position [ Z_AXIS ] ;
}
float measure_business_card_thickness ( const float & in_height ) {
2017-04-06 23:46:47 +00:00
ubl . has_control_of_lcd_panel = true ;
2017-04-02 16:48:26 +00:00
save_ubl_active_state_and_disable ( ) ; // we don't do bed level correction because we want the raw data when we probe
SERIAL_PROTOCOLLNPGM ( " Place Shim Under Nozzle and Perform Measurement. " ) ;
do_blocking_move_to_z ( in_height ) ;
do_blocking_move_to_xy ( ( float ( X_MAX_POS ) - float ( X_MIN_POS ) ) / 2.0 , ( float ( Y_MAX_POS ) - float ( Y_MIN_POS ) ) / 2.0 ) ;
2017-04-08 08:16:13 +00:00
//, min(planner.max_feedrate_mm_s[X_AXIS], planner.max_feedrate_mm_s[Y_AXIS])/2.0);
2017-04-02 16:48:26 +00:00
const float z1 = use_encoder_wheel_to_measure_point ( ) ;
do_blocking_move_to_z ( current_position [ Z_AXIS ] + SIZE_OF_LITTLE_RAISE ) ;
ubl . has_control_of_lcd_panel = false ;
SERIAL_PROTOCOLLNPGM ( " Remove Shim and Measure Bed Height. " ) ;
const float z2 = use_encoder_wheel_to_measure_point ( ) ;
do_blocking_move_to_z ( current_position [ Z_AXIS ] + SIZE_OF_LITTLE_RAISE ) ;
if ( g29_verbose_level > 1 ) {
SERIAL_PROTOCOLPGM ( " Business Card is: " ) ;
SERIAL_PROTOCOL_F ( abs ( z1 - z2 ) , 6 ) ;
SERIAL_PROTOCOLLNPGM ( " mm thick. " ) ;
}
restore_ubl_active_state_and_leave ( ) ;
return abs ( z1 - z2 ) ;
}
void manually_probe_remaining_mesh ( const float & lx , const float & ly , const float & z_clearance , const float & card_thickness , const bool do_ubl_mesh_map ) {
2017-04-06 23:46:47 +00:00
ubl . has_control_of_lcd_panel = true ;
2017-04-02 16:48:26 +00:00
save_ubl_active_state_and_disable ( ) ; // we don't do bed level correction because we want the raw data when we probe
do_blocking_move_to_z ( z_clearance ) ;
do_blocking_move_to_xy ( lx , ly ) ;
float last_x = - 9999.99 , last_y = - 9999.99 ;
mesh_index_pair location ;
do {
if ( do_ubl_mesh_map ) ubl . display_map ( map_type ) ;
location = find_closest_mesh_point_of_type ( INVALID , lx , ly , 0 , NULL , false ) ; // The '0' says we want to use the nozzle's position
// It doesn't matter if the probe can't reach the NAN location. This is a manual probe.
if ( location . x_index < 0 & & location . y_index < 0 ) continue ;
const float rawx = ubl . mesh_index_to_xpos [ location . x_index ] ,
rawy = ubl . mesh_index_to_ypos [ location . y_index ] ;
// TODO: Change to use `position_is_reachable` (for SCARA-compatibility)
if ( ! WITHIN ( rawx , X_MIN_POS , X_MAX_POS ) | | ! WITHIN ( rawy , Y_MIN_POS , Y_MAX_POS ) ) {
SERIAL_ERROR_START ;
SERIAL_ERRORLNPGM ( " Attempt to probe off the bed. " ) ;
ubl . has_control_of_lcd_panel = false ;
goto LEAVE ;
}
const float xProbe = LOGICAL_X_POSITION ( rawx ) ,
yProbe = LOGICAL_Y_POSITION ( rawy ) ,
dx = xProbe - last_x ,
dy = yProbe - last_y ;
if ( HYPOT ( dx , dy ) < BIG_RAISE_NOT_NEEDED )
do_blocking_move_to_z ( current_position [ Z_AXIS ] + SIZE_OF_LITTLE_RAISE ) ;
else
do_blocking_move_to_z ( z_clearance ) ;
do_blocking_move_to_xy ( xProbe , yProbe ) ;
last_x = xProbe ;
last_y = yProbe ;
KEEPALIVE_STATE ( PAUSED_FOR_USER ) ;
ubl . has_control_of_lcd_panel = true ;
while ( ! ubl_lcd_clicked ( ) ) { // we need the loop to move the nozzle based on the encoder wheel here!
idle ( ) ;
if ( ubl . encoder_diff ) {
do_blocking_move_to_z ( current_position [ Z_AXIS ] + float ( ubl . encoder_diff ) / 100.0 ) ;
ubl . encoder_diff = 0 ;
}
}
const millis_t nxt = millis ( ) + 1500L ;
while ( ubl_lcd_clicked ( ) ) { // debounce and watch for abort
idle ( ) ;
if ( ELAPSED ( millis ( ) , nxt ) ) {
SERIAL_PROTOCOLLNPGM ( " \n Mesh only partially populated. " ) ;
do_blocking_move_to_z ( Z_CLEARANCE_DEPLOY_PROBE ) ;
lcd_quick_feedback ( ) ;
while ( ubl_lcd_clicked ( ) ) idle ( ) ;
ubl . has_control_of_lcd_panel = false ;
KEEPALIVE_STATE ( IN_HANDLER ) ;
restore_ubl_active_state_and_leave ( ) ;
return ;
}
}
ubl . z_values [ location . x_index ] [ location . y_index ] = current_position [ Z_AXIS ] - card_thickness ;
if ( g29_verbose_level > 2 ) {
SERIAL_PROTOCOLPGM ( " Mesh Point Measured at: " ) ;
SERIAL_PROTOCOL_F ( ubl . z_values [ location . x_index ] [ location . y_index ] , 6 ) ;
SERIAL_EOL ;
}
} while ( location . x_index > = 0 & & location . y_index > = 0 ) ;
if ( do_ubl_mesh_map ) ubl . display_map ( map_type ) ;
LEAVE :
restore_ubl_active_state_and_leave ( ) ;
KEEPALIVE_STATE ( IN_HANDLER ) ;
do_blocking_move_to_z ( Z_CLEARANCE_DEPLOY_PROBE ) ;
do_blocking_move_to_xy ( lx , ly ) ;
}
bool g29_parameter_parsing ( ) {
# if ENABLED(ULTRA_LCD)
2017-04-08 08:16:13 +00:00
lcd_setstatuspgm ( PSTR ( " Doing G29 UBL! " ) ) ;
2017-04-02 16:48:26 +00:00
lcd_quick_feedback ( ) ;
# endif
2017-04-08 20:18:27 +00:00
x_pos = current_position [ X_AXIS ] ;
y_pos = current_position [ Y_AXIS ] ;
x_flag = 0 ;
y_flag = 0 ;
repeat_flag = 0 ;
2017-04-02 16:48:26 +00:00
g29_verbose_level = code_seen ( ' V ' ) ? code_value_int ( ) : 0 ;
if ( ! WITHIN ( g29_verbose_level , 0 , 4 ) ) {
SERIAL_PROTOCOLLNPGM ( " Invalid Verbose Level specified. (0-4) \n " ) ;
return UBL_ERR ;
}
2017-04-06 23:46:47 +00:00
if ( code_seen ( ' G ' ) ) {
grid_size_G = 3 ;
if ( code_has_value ( ) )
grid_size_G = code_value_int ( ) ;
if ( ! WITHIN ( grid_size_G , 2 , 10 ) ) {
SERIAL_PROTOCOLLNPGM ( " Invalid grid probe points specified. \n " ) ;
return UBL_ERR ;
}
}
2017-04-02 16:48:26 +00:00
x_flag = code_seen ( ' X ' ) & & code_has_value ( ) ;
x_pos = x_flag ? code_value_float ( ) : current_position [ X_AXIS ] ;
if ( ! WITHIN ( RAW_X_POSITION ( x_pos ) , X_MIN_POS , X_MAX_POS ) ) {
SERIAL_PROTOCOLLNPGM ( " Invalid X location specified. \n " ) ;
return UBL_ERR ;
}
y_flag = code_seen ( ' Y ' ) & & code_has_value ( ) ;
y_pos = y_flag ? code_value_float ( ) : current_position [ Y_AXIS ] ;
if ( ! WITHIN ( RAW_Y_POSITION ( y_pos ) , Y_MIN_POS , Y_MAX_POS ) ) {
SERIAL_PROTOCOLLNPGM ( " Invalid Y location specified. \n " ) ;
return UBL_ERR ;
}
if ( x_flag ! = y_flag ) {
SERIAL_PROTOCOLLNPGM ( " Both X & Y locations must be specified. \n " ) ;
return UBL_ERR ;
}
if ( code_seen ( ' A ' ) ) { // Activate the Unified Bed Leveling System
ubl . state . active = 1 ;
SERIAL_PROTOCOLLNPGM ( " Unified Bed Leveling System activated. \n " ) ;
ubl . store_state ( ) ;
}
c_flag = code_seen ( ' C ' ) & & code_has_value ( ) ;
ubl_constant = c_flag ? code_value_float ( ) : 0.0 ;
if ( code_seen ( ' D ' ) ) { // Disable the Unified Bed Leveling System
ubl . state . active = 0 ;
SERIAL_PROTOCOLLNPGM ( " Unified Bed Leveling System de-activated. \n " ) ;
ubl . store_state ( ) ;
}
# if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
if ( code_seen ( ' F ' ) & & code_has_value ( ) ) {
const float fh = code_value_float ( ) ;
if ( ! WITHIN ( fh , 0.0 , 100.0 ) ) {
SERIAL_PROTOCOLLNPGM ( " ?Bed Level Correction Fade Height Not Plausible. \n " ) ;
return UBL_ERR ;
}
ubl . state . g29_correction_fade_height = fh ;
ubl . state . g29_fade_height_multiplier = 1.0 / fh ;
}
# endif
repeat_flag = code_seen ( ' R ' ) ;
repetition_cnt = repeat_flag ? ( code_has_value ( ) ? code_value_int ( ) : 9999 ) : 1 ;
if ( repetition_cnt < 1 ) {
SERIAL_PROTOCOLLNPGM ( " Invalid Repetition count. \n " ) ;
return UBL_ERR ;
}
map_type = code_seen ( ' O ' ) & & code_has_value ( ) ? code_value_int ( ) : 0 ;
if ( ! WITHIN ( map_type , 0 , 1 ) ) {
SERIAL_PROTOCOLLNPGM ( " Invalid map type. \n " ) ;
return UBL_ERR ;
}
if ( code_seen ( ' M ' ) ) { // Check if a map type was specified
map_type = code_has_value ( ) ? code_value_int ( ) : 0 ;
if ( ! WITHIN ( map_type , 0 , 1 ) ) {
SERIAL_PROTOCOLLNPGM ( " Invalid map type. \n " ) ;
return UBL_ERR ;
}
}
return UBL_OK ;
}
/**
* This function goes away after G29 debug is complete . But for right now , it is a handy
* routine to dump binary data structures .
*/
2017-04-06 23:46:47 +00:00
/*
2017-04-02 16:48:26 +00:00
void dump ( char * const str , const float & f ) {
char * ptr ;
SERIAL_PROTOCOL ( str ) ;
SERIAL_PROTOCOL_F ( f , 8 ) ;
SERIAL_PROTOCOLPGM ( " " ) ;
ptr = ( char * ) & f ;
for ( uint8_t i = 0 ; i < 4 ; i + + )
SERIAL_PROTOCOLPAIR ( " " , hex_byte ( * ptr + + ) ) ;
SERIAL_PROTOCOLPAIR ( " isnan()= " , isnan ( f ) ) ;
SERIAL_PROTOCOLPAIR ( " isinf()= " , isinf ( f ) ) ;
if ( f = = - INFINITY )
SERIAL_PROTOCOLPGM ( " Minus Infinity detected. " ) ;
SERIAL_EOL ;
}
2017-04-06 23:46:47 +00:00
*/
2017-04-02 16:48:26 +00:00
static int ubl_state_at_invocation = 0 ,
ubl_state_recursion_chk = 0 ;
void save_ubl_active_state_and_disable ( ) {
ubl_state_recursion_chk + + ;
if ( ubl_state_recursion_chk ! = 1 ) {
SERIAL_ECHOLNPGM ( " save_ubl_active_state_and_disabled() called multiple times in a row. " ) ;
2017-04-08 08:16:13 +00:00
lcd_setstatuspgm ( PSTR ( " save_UBL_active() error " ) ) ;
2017-04-02 16:48:26 +00:00
lcd_quick_feedback ( ) ;
return ;
}
ubl_state_at_invocation = ubl . state . active ;
ubl . state . active = 0 ;
}
void restore_ubl_active_state_and_leave ( ) {
if ( - - ubl_state_recursion_chk ) {
SERIAL_ECHOLNPGM ( " restore_ubl_active_state_and_leave() called too many times. " ) ;
2017-04-08 08:16:13 +00:00
lcd_setstatuspgm ( PSTR ( " restore_UBL_active() error " ) ) ;
2017-04-02 16:48:26 +00:00
lcd_quick_feedback ( ) ;
return ;
}
ubl . state . active = ubl_state_at_invocation ;
}
/**
* Much of the ' What ? ' command can be eliminated . But until we are fully debugged , it is
* good to have the extra information . Soon . . . we prune this to just a few items
*/
void g29_what_command ( ) {
const uint16_t k = E2END - ubl . eeprom_start ;
SERIAL_PROTOCOLPGM ( " Unified Bed Leveling System Version " UBL_VERSION " " ) ;
if ( ubl . state . active )
SERIAL_PROTOCOLCHAR ( ' A ' ) ;
else
2017-04-03 00:48:43 +00:00
SERIAL_PROTOCOLPGM ( " Ina " ) ;
2017-04-02 16:48:26 +00:00
SERIAL_PROTOCOLLNPGM ( " ctive. \n " ) ;
safe_delay ( 50 ) ;
if ( ubl . state . eeprom_storage_slot = = - 1 )
SERIAL_PROTOCOLPGM ( " No Mesh Loaded. " ) ;
else {
SERIAL_PROTOCOLPAIR ( " Mesh " , ubl . state . eeprom_storage_slot ) ;
SERIAL_PROTOCOLPGM ( " Loaded. " ) ;
}
SERIAL_EOL ;
safe_delay ( 50 ) ;
# if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
SERIAL_PROTOCOLLNPAIR ( " g29_correction_fade_height : " , ubl . state . g29_correction_fade_height ) ;
# endif
SERIAL_PROTOCOLPGM ( " z_offset: " ) ;
SERIAL_PROTOCOL_F ( ubl . state . z_offset , 6 ) ;
SERIAL_EOL ;
safe_delay ( 50 ) ;
SERIAL_PROTOCOLPGM ( " X-Axis Mesh Points at: " ) ;
2017-04-06 03:29:44 +00:00
for ( uint8_t i = 0 ; i < GRID_MAX_POINTS_X ; i + + ) {
2017-04-02 16:48:26 +00:00
SERIAL_PROTOCOL_F ( LOGICAL_X_POSITION ( ubl . mesh_index_to_xpos [ i ] ) , 1 ) ;
SERIAL_PROTOCOLPGM ( " " ) ;
safe_delay ( 50 ) ;
}
SERIAL_EOL ;
SERIAL_PROTOCOLPGM ( " Y-Axis Mesh Points at: " ) ;
2017-04-06 03:29:44 +00:00
for ( uint8_t i = 0 ; i < GRID_MAX_POINTS_Y ; i + + ) {
2017-04-02 16:48:26 +00:00
SERIAL_PROTOCOL_F ( LOGICAL_Y_POSITION ( ubl . mesh_index_to_ypos [ i ] ) , 1 ) ;
SERIAL_PROTOCOLPGM ( " " ) ;
safe_delay ( 50 ) ;
}
SERIAL_EOL ;
# if HAS_KILL
SERIAL_PROTOCOLPAIR ( " Kill pin on : " , KILL_PIN ) ;
SERIAL_PROTOCOLLNPAIR ( " state: " , READ ( KILL_PIN ) ) ;
# endif
SERIAL_EOL ;
safe_delay ( 50 ) ;
SERIAL_PROTOCOLLNPAIR ( " ubl_state_at_invocation : " , ubl_state_at_invocation ) ;
SERIAL_EOL ;
SERIAL_PROTOCOLLNPAIR ( " ubl_state_recursion_chk : " , ubl_state_recursion_chk ) ;
SERIAL_EOL ;
safe_delay ( 50 ) ;
SERIAL_PROTOCOLLNPAIR ( " Free EEPROM space starts at: 0x " , hex_word ( ubl . eeprom_start ) ) ;
SERIAL_PROTOCOLLNPAIR ( " end of EEPROM : 0x " , hex_word ( E2END ) ) ;
safe_delay ( 50 ) ;
SERIAL_PROTOCOLLNPAIR ( " sizeof(ubl) : " , ( int ) sizeof ( ubl ) ) ;
SERIAL_EOL ;
SERIAL_PROTOCOLLNPAIR ( " z_value[][] size: " , ( int ) sizeof ( ubl . z_values ) ) ;
SERIAL_EOL ;
safe_delay ( 50 ) ;
SERIAL_PROTOCOLLNPAIR ( " EEPROM free for UBL: 0x " , hex_word ( k ) ) ;
safe_delay ( 50 ) ;
SERIAL_PROTOCOLPAIR ( " EEPROM can hold " , k / sizeof ( ubl . z_values ) ) ;
SERIAL_PROTOCOLLNPGM ( " meshes. \n " ) ;
safe_delay ( 50 ) ;
SERIAL_PROTOCOLPAIR ( " sizeof(ubl.state) : " , ( int ) sizeof ( ubl . state ) ) ;
2017-04-06 03:29:44 +00:00
SERIAL_PROTOCOLPAIR ( " \n GRID_MAX_POINTS_X " , GRID_MAX_POINTS_X ) ;
SERIAL_PROTOCOLPAIR ( " \n GRID_MAX_POINTS_Y " , GRID_MAX_POINTS_Y ) ;
2017-04-02 16:48:26 +00:00
safe_delay ( 50 ) ;
SERIAL_PROTOCOLPAIR ( " \n UBL_MESH_MIN_X " , UBL_MESH_MIN_X ) ;
SERIAL_PROTOCOLPAIR ( " \n UBL_MESH_MIN_Y " , UBL_MESH_MIN_Y ) ;
safe_delay ( 50 ) ;
SERIAL_PROTOCOLPAIR ( " \n UBL_MESH_MAX_X " , UBL_MESH_MAX_X ) ;
SERIAL_PROTOCOLPAIR ( " \n UBL_MESH_MAX_Y " , UBL_MESH_MAX_Y ) ;
safe_delay ( 50 ) ;
SERIAL_PROTOCOLPGM ( " \n MESH_X_DIST " ) ;
SERIAL_PROTOCOL_F ( MESH_X_DIST , 6 ) ;
SERIAL_PROTOCOLPGM ( " \n MESH_Y_DIST " ) ;
SERIAL_PROTOCOL_F ( MESH_Y_DIST , 6 ) ;
SERIAL_EOL ;
safe_delay ( 50 ) ;
if ( ! ubl . sanity_check ( ) )
SERIAL_PROTOCOLLNPGM ( " Unified Bed Leveling sanity checks passed. " ) ;
}
/**
* When we are fully debugged , the EEPROM dump command will get deleted also . But
* right now , it is good to have the extra information . Soon . . . we prune this .
*/
void g29_eeprom_dump ( ) {
unsigned char cccc ;
uint16_t kkkk ;
SERIAL_ECHO_START ;
SERIAL_ECHOLNPGM ( " EEPROM Dump: " ) ;
for ( uint16_t i = 0 ; i < E2END + 1 ; i + = 16 ) {
if ( ! ( i & 0x3 ) ) idle ( ) ;
print_hex_word ( i ) ;
SERIAL_ECHOPGM ( " : " ) ;
for ( uint16_t j = 0 ; j < 16 ; j + + ) {
kkkk = i + j ;
eeprom_read_block ( & cccc , ( void * ) kkkk , 1 ) ;
print_hex_byte ( cccc ) ;
SERIAL_ECHO ( ' ' ) ;
}
SERIAL_EOL ;
}
SERIAL_EOL ;
}
/**
* When we are fully debugged , this may go away . But there are some valid
* use cases for the users . So we can wait and see what to do with it .
*/
void g29_compare_current_mesh_to_stored_mesh ( ) {
2017-04-06 03:29:44 +00:00
float tmp_z_values [ GRID_MAX_POINTS_X ] [ GRID_MAX_POINTS_Y ] ;
2017-04-02 16:48:26 +00:00
if ( ! code_has_value ( ) ) {
SERIAL_PROTOCOLLNPGM ( " ?Mesh # required. \n " ) ;
return ;
}
storage_slot = code_value_int ( ) ;
int16_t j = ( UBL_LAST_EEPROM_INDEX - ubl . eeprom_start ) / sizeof ( tmp_z_values ) ;
if ( ! WITHIN ( storage_slot , 0 , j - 1 ) | | ubl . eeprom_start < = 0 ) {
SERIAL_PROTOCOLLNPGM ( " ?EEPROM storage not available for use. \n " ) ;
return ;
}
j = UBL_LAST_EEPROM_INDEX - ( storage_slot + 1 ) * sizeof ( tmp_z_values ) ;
eeprom_read_block ( ( void * ) & tmp_z_values , ( void * ) j , sizeof ( tmp_z_values ) ) ;
SERIAL_ECHOPAIR ( " Subtracting Mesh " , storage_slot ) ;
SERIAL_PROTOCOLLNPAIR ( " loaded from EEPROM address 0x " , hex_word ( j ) ) ; // Soon, we can remove the extra clutter of printing
// the address in the EEPROM where the Mesh is stored.
2017-04-06 03:29:44 +00:00
for ( uint8_t x = 0 ; x < GRID_MAX_POINTS_X ; x + + )
for ( uint8_t y = 0 ; y < GRID_MAX_POINTS_Y ; y + + )
2017-04-02 16:48:26 +00:00
ubl . z_values [ x ] [ y ] - = tmp_z_values [ x ] [ y ] ;
}
mesh_index_pair find_closest_mesh_point_of_type ( const MeshPointType type , const float & lx , const float & ly , const bool probe_as_reference , unsigned int bits [ 16 ] , bool far_flag ) {
float distance , closest = far_flag ? - 99999.99 : 99999.99 ;
mesh_index_pair return_val ;
return_val . x_index = return_val . y_index = - 1 ;
const float current_x = current_position [ X_AXIS ] ,
current_y = current_position [ Y_AXIS ] ;
// Get our reference position. Either the nozzle or probe location.
const float px = lx - ( probe_as_reference ? X_PROBE_OFFSET_FROM_EXTRUDER : 0 ) ,
py = ly - ( probe_as_reference ? Y_PROBE_OFFSET_FROM_EXTRUDER : 0 ) ;
2017-04-06 03:29:44 +00:00
for ( uint8_t i = 0 ; i < GRID_MAX_POINTS_X ; i + + ) {
for ( uint8_t j = 0 ; j < GRID_MAX_POINTS_Y ; j + + ) {
2017-04-02 16:48:26 +00:00
if ( ( type = = INVALID & & isnan ( ubl . z_values [ i ] [ j ] ) ) // Check to see if this location holds the right thing
| | ( type = = REAL & & ! isnan ( ubl . z_values [ i ] [ j ] ) )
| | ( type = = SET_IN_BITMAP & & is_bit_set ( bits , i , j ) )
) {
// We only get here if we found a Mesh Point of the specified type
const float rawx = ubl . mesh_index_to_xpos [ i ] , // Check if we can probe this mesh location
rawy = ubl . mesh_index_to_ypos [ j ] ;
// If using the probe as the reference there are some unreachable locations.
// Prune them from the list and ignore them till the next Phase (manual nozzle probing).
if ( probe_as_reference & &
( ! WITHIN ( rawx , MIN_PROBE_X , MAX_PROBE_X ) | | ! WITHIN ( rawy , MIN_PROBE_Y , MAX_PROBE_Y ) )
) continue ;
// Unreachable. Check if it's the closest location to the nozzle.
// Add in a weighting factor that considers the current location of the nozzle.
const float mx = LOGICAL_X_POSITION ( rawx ) , // Check if we can probe this mesh location
my = LOGICAL_Y_POSITION ( rawy ) ;
distance = HYPOT ( px - mx , py - my ) + HYPOT ( current_x - mx , current_y - my ) * 0.1 ;
if ( far_flag ) { // If doing the far_flag action, we want to be as far as possible
2017-04-06 03:29:44 +00:00
for ( uint8_t k = 0 ; k < GRID_MAX_POINTS_X ; k + + ) { // from the starting point and from any other probed points. We
for ( uint8_t l = 0 ; l < GRID_MAX_POINTS_Y ; l + + ) { // want the next point spread out and filling in any blank spaces
2017-04-02 16:48:26 +00:00
if ( ! isnan ( ubl . z_values [ k ] [ l ] ) ) { // in the mesh. So we add in some of the distance to every probed
distance + = sq ( i - k ) * ( MESH_X_DIST ) * .05 // point we can find.
+ sq ( j - l ) * ( MESH_Y_DIST ) * .05 ;
}
}
}
}
if ( far_flag = = ( distance > closest ) & & distance ! = closest ) { // if far_flag, look for farthest point
closest = distance ; // We found a closer/farther location with
return_val . x_index = i ; // the specified type of mesh value.
return_val . y_index = j ;
return_val . distance = closest ;
}
}
} // for j
} // for i
return return_val ;
}
void fine_tune_mesh ( const float & lx , const float & ly , const bool do_ubl_mesh_map ) {
mesh_index_pair location ;
uint16_t not_done [ 16 ] ;
int32_t round_off ;
save_ubl_active_state_and_disable ( ) ;
memset ( not_done , 0xFF , sizeof ( not_done ) ) ;
# if ENABLED(ULTRA_LCD)
2017-04-08 08:16:13 +00:00
lcd_setstatuspgm ( PSTR ( " Fine Tuning Mesh " ) ) ;
2017-04-02 16:48:26 +00:00
# endif
do_blocking_move_to_z ( Z_CLEARANCE_DEPLOY_PROBE ) ;
do_blocking_move_to_xy ( lx , ly ) ;
do {
if ( do_ubl_mesh_map ) ubl . display_map ( map_type ) ;
2017-04-08 08:16:13 +00:00
location = find_closest_mesh_point_of_type ( SET_IN_BITMAP , lx , ly , 0 , not_done , false ) ; // The '0' says we want to use the nozzle's position
2017-04-02 16:48:26 +00:00
// It doesn't matter if the probe can not reach this
// location. This is a manual edit of the Mesh Point.
if ( location . x_index < 0 & & location . y_index < 0 ) continue ; // abort if we can't find any more points.
bit_clear ( not_done , location . x_index , location . y_index ) ; // Mark this location as 'adjusted' so we will find a
// different location the next time through the loop
const float rawx = ubl . mesh_index_to_xpos [ location . x_index ] ,
rawy = ubl . mesh_index_to_ypos [ location . y_index ] ;
// TODO: Change to use `position_is_reachable` (for SCARA-compatibility)
if ( ! WITHIN ( rawx , X_MIN_POS , X_MAX_POS ) | | ! WITHIN ( rawy , Y_MIN_POS , Y_MAX_POS ) ) { // In theory, we don't need this check.
SERIAL_ERROR_START ;
SERIAL_ERRORLNPGM ( " Attempt to edit off the bed. " ) ; // This really can't happen, but do the check for now
ubl . has_control_of_lcd_panel = false ;
goto FINE_TUNE_EXIT ;
}
do_blocking_move_to_z ( Z_CLEARANCE_DEPLOY_PROBE ) ; // Move the nozzle to where we are going to edit
do_blocking_move_to_xy ( LOGICAL_X_POSITION ( rawx ) , LOGICAL_Y_POSITION ( rawy ) ) ;
float new_z = ubl . z_values [ location . x_index ] [ location . y_index ] ;
round_off = ( int32_t ) ( new_z * 1000.0 ) ; // we chop off the last digits just to be clean. We are rounding to the
new_z = float ( round_off ) / 1000.0 ;
KEEPALIVE_STATE ( PAUSED_FOR_USER ) ;
ubl . has_control_of_lcd_panel = true ;
lcd_implementation_clear ( ) ;
lcd_mesh_edit_setup ( new_z ) ;
do {
new_z = lcd_mesh_edit ( ) ;
idle ( ) ;
} while ( ! ubl_lcd_clicked ( ) ) ;
lcd_return_to_status ( ) ;
ubl . has_control_of_lcd_panel = true ; // There is a race condition for the Encoder Wheel getting clicked.
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune)
// or here.
const millis_t nxt = millis ( ) + 1500UL ;
while ( ubl_lcd_clicked ( ) ) { // debounce and watch for abort
idle ( ) ;
if ( ELAPSED ( millis ( ) , nxt ) ) {
lcd_return_to_status ( ) ;
//SERIAL_PROTOCOLLNPGM("\nFine Tuning of Mesh Stopped.");
do_blocking_move_to_z ( Z_CLEARANCE_DEPLOY_PROBE ) ;
2017-04-08 08:16:13 +00:00
lcd_setstatuspgm ( PSTR ( " Mesh Editing Stopped " ) ) ;
2017-04-02 16:48:26 +00:00
while ( ubl_lcd_clicked ( ) ) idle ( ) ;
goto FINE_TUNE_EXIT ;
}
}
safe_delay ( 20 ) ; // We don't want any switch noise.
ubl . z_values [ location . x_index ] [ location . y_index ] = new_z ;
lcd_implementation_clear ( ) ;
} while ( location . x_index > = 0 & & location . y_index > = 0 & & - - repetition_cnt ) ;
FINE_TUNE_EXIT :
ubl . has_control_of_lcd_panel = false ;
KEEPALIVE_STATE ( IN_HANDLER ) ;
if ( do_ubl_mesh_map ) ubl . display_map ( map_type ) ;
restore_ubl_active_state_and_leave ( ) ;
do_blocking_move_to_z ( Z_CLEARANCE_DEPLOY_PROBE ) ;
do_blocking_move_to_xy ( lx , ly ) ;
# if ENABLED(ULTRA_LCD)
2017-04-08 08:16:13 +00:00
lcd_setstatuspgm ( PSTR ( " Done Editing Mesh " ) ) ;
2017-04-02 16:48:26 +00:00
# endif
SERIAL_ECHOLNPGM ( " Done Editing Mesh " ) ;
}
2017-04-08 08:16:13 +00:00
void tilt_mesh_based_on_probed_grid ( const bool do_ubl_mesh_map ) {
int8_t grid_G_index_to_xpos [ grid_size_G ] , // UBL MESH X index to be probed
grid_G_index_to_ypos [ grid_size_G ] , // UBL MESH Y index to be probed
i , j , k , xCount , yCount , G_X_index , G_Y_index ; // counter variables
2017-04-06 23:46:47 +00:00
float z_values_G [ grid_size_G ] [ grid_size_G ] ;
2017-04-08 08:16:13 +00:00
linear_fit * results ;
2017-04-06 23:46:47 +00:00
for ( G_Y_index = 0 ; G_Y_index < grid_size_G ; G_Y_index + + )
for ( G_X_index = 0 ; G_X_index < grid_size_G ; G_X_index + + )
z_values_G [ G_X_index ] [ G_Y_index ] = NAN ;
2017-04-08 08:16:13 +00:00
uint8_t x_min = GRID_MAX_POINTS_X - 1 ,
x_max = 0 ,
y_min = GRID_MAX_POINTS_Y - 1 ,
y_max = 0 ;
2017-04-06 23:46:47 +00:00
//find min & max probeable points in the mesh
2017-04-08 08:16:13 +00:00
for ( xCount = 0 ; xCount < GRID_MAX_POINTS_X ; xCount + + ) {
for ( yCount = 0 ; yCount < GRID_MAX_POINTS_Y ; yCount + + ) {
2017-04-06 23:46:47 +00:00
if ( WITHIN ( ubl . mesh_index_to_xpos [ xCount ] , MIN_PROBE_X , MAX_PROBE_X ) & & WITHIN ( ubl . mesh_index_to_ypos [ yCount ] , MIN_PROBE_Y , MAX_PROBE_Y ) ) {
2017-04-08 08:16:13 +00:00
NOMORE ( x_min , xCount ) ;
NOLESS ( x_max , xCount ) ;
NOMORE ( y_min , yCount ) ;
NOLESS ( y_max , yCount ) ;
2017-04-06 23:46:47 +00:00
}
}
}
2017-04-08 08:16:13 +00:00
if ( x_max - x_min + 1 < grid_size_G | | y_max - y_min + 1 < grid_size_G ) {
2017-04-07 03:10:12 +00:00
SERIAL_ECHOPAIR ( " ERROR - probeable UBL MESH smaller than grid - X points: " , x_max - x_min + 1 ) ;
SERIAL_ECHOPAIR ( " Y points: " , y_max - y_min + 1 ) ;
SERIAL_ECHOLNPAIR ( " grid: " , grid_size_G ) ;
2017-04-06 23:46:47 +00:00
return ;
}
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
// populate X matrix
for ( G_X_index = 0 ; G_X_index < grid_size_G ; G_X_index + + ) {
2017-04-08 08:16:13 +00:00
grid_G_index_to_xpos [ G_X_index ] = x_min + G_X_index * ( x_max - x_min ) / ( grid_size_G - 1 ) ;
if ( G_X_index > 0 & & grid_G_index_to_xpos [ G_X_index - 1 ] = = grid_G_index_to_xpos [ G_X_index ] ) {
2017-04-06 23:46:47 +00:00
grid_G_index_to_xpos [ G_X_index ] = grid_G_index_to_xpos [ G_X_index - 1 ] + 1 ;
}
}
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
// populate Y matrix
for ( G_Y_index = 0 ; G_Y_index < grid_size_G ; G_Y_index + + ) {
2017-04-08 08:16:13 +00:00
grid_G_index_to_ypos [ G_Y_index ] = y_min + G_Y_index * ( y_max - y_min ) / ( grid_size_G - 1 ) ;
if ( G_Y_index > 0 & & grid_G_index_to_ypos [ G_Y_index - 1 ] = = grid_G_index_to_ypos [ G_Y_index ] ) {
2017-04-06 23:46:47 +00:00
grid_G_index_to_ypos [ G_Y_index ] = grid_G_index_to_ypos [ G_Y_index - 1 ] + 1 ;
}
}
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
ubl . has_control_of_lcd_panel = true ;
save_ubl_active_state_and_disable ( ) ; // we don't do bed level correction because we want the raw data when we probe
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
DEPLOY_PROBE ( ) ;
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
// this is a copy of the G29 AUTO_BED_LEVELING_BILINEAR method/code
# undef PROBE_Y_FIRST
# if ENABLED(PROBE_Y_FIRST)
# define PR_OUTER_VAR xCount
# define PR_OUTER_NUM grid_size_G
# define PR_INNER_VAR yCount
# define PR_INNER_NUM grid_size_G
# else
# define PR_OUTER_VAR yCount
# define PR_OUTER_NUM grid_size_G
# define PR_INNER_VAR xCount
# define PR_INNER_NUM grid_size_G
# endif
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
bool zig = PR_OUTER_NUM & 1 ; // Always end at RIGHT and BACK_PROBE_BED_POSITION
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
// Outer loop is Y with PROBE_Y_FIRST disabled
for ( PR_OUTER_VAR = 0 ; PR_OUTER_VAR < PR_OUTER_NUM ; PR_OUTER_VAR + + ) {
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
int8_t inStart , inStop , inInc ;
2017-04-08 08:16:13 +00:00
SERIAL_ECHOPAIR ( " \n PR_OUTER_VAR: " , PR_OUTER_VAR ) ;
2017-04-06 23:46:47 +00:00
if ( zig ) { // away from origin
inStart = 0 ;
inStop = PR_INNER_NUM ;
inInc = 1 ;
}
else { // towards origin
inStart = PR_INNER_NUM - 1 ;
inStop = - 1 ;
inInc = - 1 ;
}
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
zig = ! zig ; // zag
2017-04-08 08:16:13 +00:00
2017-04-06 23:46:47 +00:00
// Inner loop is Y with PROBE_Y_FIRST enabled
for ( PR_INNER_VAR = inStart ; PR_INNER_VAR ! = inStop ; PR_INNER_VAR + = inInc ) {
2017-04-08 08:16:13 +00:00
//SERIAL_ECHOPAIR("\nPR_INNER_VAR: ", PR_INNER_VAR);
//SERIAL_ECHOPAIR("\nCheckpoint: ", 1);
2017-04-06 23:46:47 +00:00
// end of G29 AUTO_BED_LEVELING_BILINEAR method/code
if ( ubl_lcd_clicked ( ) ) {
2017-04-08 08:16:13 +00:00
//SERIAL_ECHOPAIR("\nCheckpoint: ", 2);
2017-04-07 03:10:12 +00:00
SERIAL_ECHOLNPGM ( " \n Grid only partially populated. \n " ) ;
2017-04-06 23:46:47 +00:00
lcd_quick_feedback ( ) ;
STOW_PROBE ( ) ;
2017-04-08 08:16:13 +00:00
//SERIAL_ECHOPAIR("\nCheckpoint: ", 3);
2017-04-06 23:46:47 +00:00
while ( ubl_lcd_clicked ( ) ) idle ( ) ;
2017-04-08 08:16:13 +00:00
//SERIAL_ECHOPAIR("\nCheckpoint: ", 4);
ubl . has_control_of_lcd_panel = false ;
restore_ubl_active_state_and_leave ( ) ;
safe_delay ( 50 ) ; // Debounce the Encoder wheel
return ;
}
//SERIAL_ECHOPAIR("\nCheckpoint: ", 5);
2017-04-06 23:46:47 +00:00
const float probeX = ubl . mesh_index_to_xpos [ grid_G_index_to_xpos [ xCount ] ] , //where we want the probe to be
probeY = ubl . mesh_index_to_ypos [ grid_G_index_to_ypos [ yCount ] ] ;
2017-04-08 08:16:13 +00:00
//SERIAL_ECHOPAIR("\nCheckpoint: ", 6);
2017-04-06 23:46:47 +00:00
2017-04-08 08:16:13 +00:00
const float measured_z = probe_pt ( LOGICAL_X_POSITION ( probeX ) , LOGICAL_Y_POSITION ( probeY ) , code_seen ( ' E ' ) , ( code_seen ( ' V ' ) & & code_has_value ( ) ) ? code_value_int ( ) : 0 ) ; // takes into account the offsets
//SERIAL_ECHOPAIR("\nmeasured_z: ", measured_z);
2017-04-06 23:46:47 +00:00
z_values_G [ xCount ] [ yCount ] = measured_z ;
2017-04-08 08:16:13 +00:00
//SERIAL_ECHOLNPGM("\nFine Tuning of Mesh Stopped.");
2017-04-06 23:46:47 +00:00
}
}
2017-04-08 08:16:13 +00:00
//SERIAL_ECHOLNPGM("\nDone probing...\n");
2017-04-06 23:46:47 +00:00
STOW_PROBE ( ) ;
restore_ubl_active_state_and_leave ( ) ;
2017-04-08 08:16:13 +00:00
// ?? ubl.has_control_of_lcd_panel = true;
//do_blocking_move_to_xy(ubl.mesh_index_to_xpos[grid_G_index_to_xpos[0]], ubl.mesh_index_to_ypos[grid_G_index_to_ypos[0]]);
2017-04-06 23:46:47 +00:00
// least squares code
2017-04-08 08:16:13 +00:00
double xxx9 [ ] = { 0 , 50 , 100 , 150 , 200 , 20 , 70 , 120 , 165 , 195 , 0 , 50 , 100 , 150 , 200 , 0 , 55 , 100 , 150 , 200 , 0 , 65 , 100 , 150 , 205 } ,
yyy9 [ ] = { 0 , 1 , 2 , 3 , 4 , 50 , 51 , 52 , 53 , 54 , 100 , 101 , 102 , 103 , 104 , 150 , 151 , 152 , 153 , 154 , 200 , 201 , 202 , 203 , 204 } ,
zzz9 [ ] = { 0.01 , .002 , - .01 , - .02 , 0 , 0.01 , .002 , - .01 , - .02 , 0 , 0.01 , .002 , - .01 , - .02 , 0 , 0.01 , .002 , - .01 , - .02 , 0 , 0.01 , .002 , - .01 , - .012 , 0.01 } ,
xxx0 [ ] = { 0.0 , 0.0 , 1.0 } , // Expect [0,0,0.1,0]
yyy0 [ ] = { 0.0 , 1.0 , 0.0 } ,
zzz0 [ ] = { 0.1 , 0.1 , 0.1 } ,
xxx [ ] = { 0.0 , 0.0 , 1.0 , 1.0 } , // Expect [0.1,0,0.05,0]
yyy [ ] = { 0.0 , 1.0 , 0.0 , 1.0 } ,
zzz [ ] = { 0.05 , 0.05 , 0.15 , 0.15 } ;
results = lsf_linear_fit ( xxx9 , yyy9 , zzz9 , COUNT ( xxx9 ) ) ;
SERIAL_ECHOPAIR ( " \n xxx9->A = " , results - > A ) ;
SERIAL_ECHOPAIR ( " \n xxx9->B = " , results - > B ) ;
SERIAL_ECHOPAIR ( " \n xxx9->D = " , results - > D ) ;
SERIAL_EOL ;
results = lsf_linear_fit ( xxx0 , yyy0 , zzz0 , COUNT ( xxx0 ) ) ;
SERIAL_ECHOPAIR ( " \n xxx0->A = " , results - > A ) ;
SERIAL_ECHOPAIR ( " \n xxx0->B = " , results - > B ) ;
SERIAL_ECHOPAIR ( " \n xxx0->D = " , results - > D ) ;
SERIAL_EOL ;
results = lsf_linear_fit ( xxx , yyy , zzz , COUNT ( xxx ) ) ;
SERIAL_ECHOPAIR ( " \n xxx->A = " , results - > A ) ;
SERIAL_ECHOPAIR ( " \n xxx->B = " , results - > B ) ;
SERIAL_ECHOPAIR ( " \n xxx->D = " , results - > D ) ;
SERIAL_EOL ;
2017-04-06 23:46:47 +00:00
} // end of tilt_mesh_based_on_probed_grid()
2017-04-02 21:13:15 +00:00
# endif // AUTO_BED_LEVELING_UBL