General option PAUSE_BEFORE_DEPLOY_STOW (#11905)
This commit is contained in:
parent
849dea92a8
commit
217e0efd20
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -773,9 +773,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -870,6 +867,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -736,9 +736,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -833,6 +830,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -736,9 +736,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -833,6 +830,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -801,9 +801,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -927,6 +924,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -760,9 +760,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -857,6 +854,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -725,9 +725,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -822,6 +819,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -725,9 +725,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -822,6 +819,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -741,9 +741,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -838,6 +835,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -754,9 +754,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -851,6 +848,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -741,9 +741,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -838,6 +835,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -752,9 +752,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -849,6 +846,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -763,9 +763,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -860,6 +857,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -757,9 +757,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -854,6 +851,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -772,9 +772,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -869,6 +866,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -763,9 +763,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -860,6 +857,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -757,9 +757,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -854,6 +851,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -757,9 +757,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -854,6 +851,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -763,9 +763,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -860,6 +857,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -764,9 +764,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -860,6 +857,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -735,9 +735,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -832,6 +829,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -735,9 +735,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -832,6 +829,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -759,9 +759,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -856,6 +853,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -777,9 +777,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -874,6 +871,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -788,9 +788,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -885,6 +882,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -768,9 +768,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -865,6 +862,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -769,9 +769,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -866,6 +863,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -768,9 +768,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -865,6 +862,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -757,9 +757,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -854,6 +851,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -765,9 +765,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -862,6 +859,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -773,9 +773,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -870,6 +867,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -745,9 +745,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -846,6 +843,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -752,9 +752,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -849,6 +846,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -757,9 +757,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -854,6 +851,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -757,9 +757,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -854,6 +851,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -793,9 +793,6 @@ Black rubber belt(MXL), 18 - tooth aluminium pulley : 87.489 step per mm (Huxley
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -890,6 +887,9 @@ Black rubber belt(MXL), 18 - tooth aluminium pulley : 87.489 step per mm (Huxley
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -751,9 +751,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -848,6 +845,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -766,9 +766,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -863,6 +860,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -755,9 +755,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -852,6 +849,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -784,9 +784,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -881,6 +878,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -804,9 +804,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -901,6 +898,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -764,9 +764,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -861,6 +858,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -782,9 +782,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -879,6 +876,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -763,9 +763,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -860,6 +857,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -753,9 +753,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -850,6 +847,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -875,9 +875,6 @@
|
|||
*/
|
||||
#if ANYCUBIC_PROBE_VERSION > 0
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
#endif
|
||||
|
||||
/**
|
||||
|
@ -1025,6 +1022,9 @@
|
|||
#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
#endif
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -835,9 +835,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -978,6 +975,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -835,9 +835,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -977,6 +974,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -835,9 +835,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -977,6 +974,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -840,9 +840,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -980,6 +977,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -825,9 +825,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -965,6 +962,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -825,9 +825,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -967,6 +964,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -818,9 +818,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -968,6 +965,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -828,9 +828,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -968,6 +965,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -766,9 +766,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -863,6 +860,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -756,9 +756,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -853,6 +850,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -755,9 +755,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -852,6 +849,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -748,9 +748,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -845,6 +842,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -758,9 +758,6 @@
|
|||
* (e.g., an inductive probe or a nozzle-based probe-switch.)
|
||||
*/
|
||||
//#define FIX_MOUNTED_PROBE
|
||||
#if ENABLED(FIX_MOUNTED_PROBE)
|
||||
//#define MANUAL_DEPLOY_STOW
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Z Servo Probe, such as an endstop switch on a rotating arm.
|
||||
|
@ -855,6 +852,9 @@
|
|||
// Enable the M48 repeatability test to test probe accuracy
|
||||
//#define Z_MIN_PROBE_REPEATABILITY_TEST
|
||||
|
||||
// Before deploy/stow pause for user confirmation
|
||||
//#define PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
* Heaters and/or fans can be disabled during probing to minimize electrical
|
||||
|
|
|
@ -379,8 +379,8 @@ bool set_probe_deployed(const bool deploy) {
|
|||
|
||||
// Make room for probe to deploy (or stow)
|
||||
// Fix-mounted probe should only raise for deploy
|
||||
// unless MANUAL_DEPLOY_STOW is enabled
|
||||
#if ENABLED(FIX_MOUNTED_PROBE) && DISABLED(MANUAL_DEPLOY_STOW)
|
||||
// unless PAUSE_BEFORE_DEPLOY_STOW is enabled
|
||||
#if ENABLED(FIX_MOUNTED_PROBE) && DISABLED(PAUSE_BEFORE_DEPLOY_STOW)
|
||||
const bool deploy_stow_condition = deploy;
|
||||
#else
|
||||
constexpr bool deploy_stow_condition = true;
|
||||
|
@ -425,6 +425,24 @@ bool set_probe_deployed(const bool deploy) {
|
|||
// otherwise an Allen-Key probe can't be stowed.
|
||||
#endif
|
||||
|
||||
#if ENABLED(PAUSE_BEFORE_DEPLOY_STOW)
|
||||
|
||||
BUZZ(100, 659);
|
||||
BUZZ(100, 698);
|
||||
|
||||
const char * const ds_str = deploy ? PSTR(MSG_MANUAL_DEPLOY) : PSTR(MSG_MANUAL_STOW);
|
||||
lcd_setalertstatusPGM(ds_str);
|
||||
serialprintPGM(ds_str);
|
||||
SERIAL_EOL();
|
||||
|
||||
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
||||
wait_for_user = true;
|
||||
while (wait_for_user) idle();
|
||||
lcd_reset_status();
|
||||
KEEPALIVE_STATE(IN_HANDLER);
|
||||
|
||||
#endif // PAUSE_BEFORE_DEPLOY_STOW
|
||||
|
||||
#if ENABLED(SOLENOID_PROBE)
|
||||
|
||||
#if HAS_SOLENOID_1
|
||||
|
@ -443,24 +461,6 @@ bool set_probe_deployed(const bool deploy) {
|
|||
|
||||
deploy ? run_deploy_moves_script() : run_stow_moves_script();
|
||||
|
||||
#elif ENABLED(MANUAL_DEPLOY_STOW)
|
||||
|
||||
do_probe_raise(Z_CLEARANCE_DEPLOY_PROBE);
|
||||
|
||||
BUZZ(100, 659);
|
||||
BUZZ(100, 698);
|
||||
|
||||
const char * const ds_str = deploy ? PSTR(MSG_MANUAL_DEPLOY) : PSTR(MSG_MANUAL_STOW);
|
||||
lcd_setalertstatusPGM(ds_str);
|
||||
serialprintPGM(ds_str);
|
||||
SERIAL_EOL();
|
||||
|
||||
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
||||
wait_for_user = true;
|
||||
while (wait_for_user) idle();
|
||||
lcd_reset_status();
|
||||
KEEPALIVE_STATE(IN_HANDLER);
|
||||
|
||||
#endif
|
||||
|
||||
#ifdef _TRIGGERED_WHEN_STOWED_TEST
|
||||
|
|
|
@ -291,7 +291,7 @@ exec_test $1 $2 "Delta Config (FLSUN AC because it's complex)"
|
|||
# SCARA with TMC2130
|
||||
#
|
||||
use_example_configs SCARA
|
||||
opt_enable AUTO_BED_LEVELING_BILINEAR FIX_MOUNTED_PROBE MANUAL_DEPLOY_STOW USE_ZMIN_PLUG EEPROM_SETTINGS EEPROM_CHITCHAT ULTIMAKERCONTROLLER
|
||||
opt_enable AUTO_BED_LEVELING_BILINEAR FIX_MOUNTED_PROBE PAUSE_BEFORE_DEPLOY_STOW USE_ZMIN_PLUG EEPROM_SETTINGS EEPROM_CHITCHAT ULTIMAKERCONTROLLER
|
||||
opt_set X_DRIVER_TYPE TMC2130
|
||||
opt_set Y_DRIVER_TYPE TMC2130
|
||||
opt_set Z_DRIVER_TYPE TMC2130
|
||||
|
|
Loading…
Reference in a new issue