Fix stepper shutdown during waiting for temperatures
In the wait loops of M109 M190 idle() is called, what checks stepper_inactive_time against previous_cmd_ms. Because we can be several minutes inside the loop, resetting previous_cmd_ms only outside the loop caused stepper shutdowns. The name of previous_cmd_ms does not really reflect its use. It's set not only when a new command was received or executed but also in many of the movement routines. For that the little extension of using it during the wait will (hopefully) not hurt. # Conflicts: # Marlin/Configuration_adv.h
This commit is contained in:
parent
b6e69e71ce
commit
32ae9f9ab7
|
@ -3975,6 +3975,7 @@ inline void gcode_M109() {
|
|||
}
|
||||
|
||||
idle();
|
||||
refresh_cmd_timeout(); // to prevent stepper_inactive_time from running out
|
||||
|
||||
#ifdef TEMP_RESIDENCY_TIME
|
||||
// start/restart the TEMP_RESIDENCY_TIME timer whenever we reach target temp for the first time
|
||||
|
@ -3989,7 +3990,6 @@ inline void gcode_M109() {
|
|||
}
|
||||
|
||||
LCD_MESSAGEPGM(MSG_HEATING_COMPLETE);
|
||||
refresh_cmd_timeout();
|
||||
print_job_start_ms = previous_cmd_ms;
|
||||
}
|
||||
|
||||
|
@ -4024,9 +4024,9 @@ inline void gcode_M109() {
|
|||
#endif
|
||||
}
|
||||
idle();
|
||||
refresh_cmd_timeout(); // to prevent stepper_inactive_time from running out
|
||||
}
|
||||
LCD_MESSAGEPGM(MSG_BED_DONE);
|
||||
refresh_cmd_timeout();
|
||||
}
|
||||
|
||||
#endif // HAS_TEMP_BED
|
||||
|
|
Loading…
Reference in a new issue