Merge pull request #4727 from thinkyhead/rc_homing_together

Add heading for movement settings
This commit is contained in:
Scott Lahteine 2016-09-01 14:26:46 -05:00 committed by GitHub
commit 3ff657e729
22 changed files with 533 additions and 464 deletions

View file

@ -430,9 +430,32 @@
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {80,80,4000,500} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {300, 300, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {3000,3000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -745,27 +768,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (4*60) #define HOMING_FEEDRATE_Z (4*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {80,80,4000,500} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {300, 300, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {3000,3000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================
//============================================================================= //=============================================================================

View file

@ -430,9 +430,32 @@
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {71.128,71.128,640,152}
#define DEFAULT_MAX_FEEDRATE {200,200,20,20} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {1000,1000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 500 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 10000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 1000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -745,26 +768,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (10*60) #define HOMING_FEEDRATE_Z (10*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {71.128,71.128,640,152}
#define DEFAULT_MAX_FEEDRATE {200,200,20,20} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {1000,1000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 500 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 10000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 1000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -412,9 +412,33 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
// default steps per unit for Felix 2.0/3.0: 0.00249mm x/y rounding error with 3mm pitch HTD belt and 14 tooth pulleys. 0 z error.
#define DEFAULT_AXIS_STEPS_PER_UNIT {76.190476, 76.190476, 1600, 164}
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {5000,5000,100,80000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 1750 // X, Y, Z and E max acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 5000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.3 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -727,27 +751,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (4*60) #define HOMING_FEEDRATE_Z (4*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
// default steps per unit for Felix 2.0/3.0: 0.00249mm x/y rounding error with 3mm pitch HTD belt and 14 tooth pulleys. 0 z error.
#define DEFAULT_AXIS_STEPS_PER_UNIT {76.190476, 76.190476, 1600, 164}
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {5000,5000,100,80000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 1750 //1500 // X, Y, Z and E max acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 5000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 10 // (mm/sec)
#define DEFAULT_ZJERK 0.3 //0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -410,9 +410,33 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
// default steps per unit for Felix 2.0/3.0: 0.00249mm x/y rounding error with 3mm pitch HTD belt and 14 tooth pulleys. 0 z error.
#define DEFAULT_AXIS_STEPS_PER_UNIT {76.190476, 76.190476, 1600, 164}
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {5000,5000,100,80000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 1750 // X, Y, Z and E max acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 5000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.3 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -725,27 +749,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (4*60) #define HOMING_FEEDRATE_Z (4*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
// default steps per unit for Felix 2.0/3.0: 0.00249mm x/y rounding error with 3mm pitch HTD belt and 14 tooth pulleys. 0 z error.
#define DEFAULT_AXIS_STEPS_PER_UNIT {76.190476, 76.190476, 1600, 164}
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {5000,5000,100,80000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 1750 //1500 // X, Y, Z and E max acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 5000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 10 // (mm/sec)
#define DEFAULT_ZJERK 0.3 //0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -422,9 +422,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {80,80,4000,100.47095761381482} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {200, 200, 3.3, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {1100,1100,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 650 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 1000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 1000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -737,26 +760,6 @@
#define HOMING_FEEDRATE_XY 2000 #define HOMING_FEEDRATE_XY 2000
#define HOMING_FEEDRATE_Z 150 #define HOMING_FEEDRATE_Z 150
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {80,80,4000,100.47095761381482} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {200, 200, 3.3, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {1100,1100,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 650 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 1000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 1000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -424,9 +424,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {160, 160, 8000, 210.02} // Steps per unit
#define DEFAULT_MAX_FEEDRATE {250, 250, 2, 200} // mm/sec
#define DEFAULT_MAX_ACCELERATION {1000, 1000, 20, 1000} // X, Y, Z, E max start speed for accelerated moves
#define DEFAULT_ACCELERATION 1000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 1000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 2.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -739,26 +762,6 @@
#define HOMING_FEEDRATE_XY (150*60) #define HOMING_FEEDRATE_XY (150*60)
#define HOMING_FEEDRATE_Z 200 #define HOMING_FEEDRATE_Z 200
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {160, 160, 8000, 210.02} // Steps per unit
#define DEFAULT_MAX_FEEDRATE {250, 250, 2, 200} // mm/sec
#define DEFAULT_MAX_ACCELERATION {1000, 1000, 20, 1000} // X, Y, Z, E max start speed for accelerated moves
#define DEFAULT_ACCELERATION 1000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 1000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 2.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -447,9 +447,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {64.25,64.25,2560,600} // default steps per unit for K8200
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 500} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 1000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 1000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 1000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -762,26 +785,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (4*60) #define HOMING_FEEDRATE_Z (4*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {64.25,64.25,2560,600} // default steps per unit for K8200
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 500} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 1000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 1000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 1000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -430,9 +430,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {134.74,134.74,4266.66,148.7} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {160, 160, 10, 10000} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 6000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 6000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.5 // (mm/sec)
#define DEFAULT_EJERK 20.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -745,26 +768,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (8*60) #define HOMING_FEEDRATE_Z (8*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {134.74,134.74,4266.66,148.7} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {160, 160, 10, 10000} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 6000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 6000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.5 // (mm/sec)
#define DEFAULT_EJERK 20.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -430,9 +430,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {134.74,134.74,4266.66,148.7} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {160, 160, 10, 10000} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 6000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 6000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.5 // (mm/sec)
#define DEFAULT_EJERK 20.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -745,26 +768,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (8*60) #define HOMING_FEEDRATE_Z (8*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {134.74,134.74,4266.66,148.7} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {160, 160, 10, 10000} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 6000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 6000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.5 // (mm/sec)
#define DEFAULT_EJERK 20.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -430,9 +430,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {78.7402*2,78.7402*2,5120.00,760*1*1.5} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {300, 300, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {3000,3000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -745,26 +768,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (4*60) #define HOMING_FEEDRATE_Z (4*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {78.7402*2,78.7402*2,5120.00,760*1*1.5} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {300, 300, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {3000,3000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -427,9 +427,33 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {44.3090, 22.1545, 1600, 53.5} // default steps per unit for RigidBot with standard hardware
// default steps for 16-tooth pulleys {100.06,50.06,1600,76}, HPX2-MAX E=504, RigidBot E=53.5, Peter Stoneham's=76
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {800, 800, 100, 10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 600 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 1000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 8.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -742,27 +766,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (15*60) #define HOMING_FEEDRATE_Z (15*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {44.3090, 22.1545, 1600, 53.5} // default steps per unit for RigidBot with standard hardware
// default steps for 16-teth polleys {100.06,50.06,1600,76}, HPX2-MAX E=504, RigidBot E=53.5, Peter Stoneham's=76
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {800, 800, 100, 10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 600 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 1000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 8.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -438,9 +438,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {103.69,106.65,200/1.25,1000} // default steps per unit for SCARA
#define DEFAULT_MAX_FEEDRATE {300, 300, 30, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {300,300,20,1000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 400 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 2000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 400 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 5.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 3.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -753,26 +776,6 @@
#define HOMING_FEEDRATE_XY (40*60) #define HOMING_FEEDRATE_XY (40*60)
#define HOMING_FEEDRATE_Z (10*60) #define HOMING_FEEDRATE_Z (10*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {103.69,106.65,200/1.25,1000} // default steps per unit for SCARA
#define DEFAULT_MAX_FEEDRATE {300, 300, 30, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {300,300,20,1000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 400 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 2000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 400 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 5 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 3 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -451,9 +451,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {100.5,100.5,400,850} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {800, 800, 8, 50} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 500 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 8.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 10.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -766,26 +789,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (8*60) #define HOMING_FEEDRATE_Z (8*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {100.5,100.5,400,850} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {800, 800, 8, 50} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 500 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 8.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 10.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -422,9 +422,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {80,80,600.0*8/3,102.073} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {350, 350, 7.2, 80} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {1000,1000,10,1000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -737,26 +760,6 @@
#define HOMING_FEEDRATE_XY (120*60) #define HOMING_FEEDRATE_XY (120*60)
#define HOMING_FEEDRATE_Z 432 #define HOMING_FEEDRATE_Z 432
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {80,80,600.0*8/3,102.073} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {350, 350, 7.2, 80} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {1000,1000,10,1000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 10.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -430,9 +430,32 @@
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {80,80,4000,500} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {300, 300, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {3000,3000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -745,26 +768,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (4*60) #define HOMING_FEEDRATE_Z (4*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {80,80,4000,500} // default steps per unit for Ultimaker
#define DEFAULT_MAX_FEEDRATE {300, 300, 5, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {3000,3000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -472,9 +472,33 @@
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
// delta speeds must be the same on xyz
#define DEFAULT_AXIS_STEPS_PER_UNIT {72.9, 72.9, 72.9, 291} // default steps per unit for BI v2.5 (cable drive)
#define DEFAULT_MAX_FEEDRATE {500, 500, 500, 150} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 15.0 // (mm/sec)
#define DEFAULT_ZJERK 15.0 // (mm/sec) Must be same as XY for delta
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -838,26 +862,6 @@
// Delta only homes to Z // Delta only homes to Z
#define HOMING_FEEDRATE_Z (200*30) #define HOMING_FEEDRATE_Z (200*30)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
// delta speeds must be the same on xyz
#define DEFAULT_AXIS_STEPS_PER_UNIT {72.9, 72.9, 72.9, 291} // default steps per unit for BI v2.5 (cable drive)
#define DEFAULT_MAX_FEEDRATE {500, 500, 500, 150} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 15.0 // (mm/sec)
#define DEFAULT_ZJERK 15.0 // (mm/sec) Must be same as XY for delta
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -472,9 +472,33 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
// delta speeds must be the same on xyz
#define DEFAULT_AXIS_STEPS_PER_UNIT {80, 80, 80, 760*1.1} // default steps per unit for Kossel (GT2, 20 tooth)
#define DEFAULT_MAX_FEEDRATE {500, 500, 500, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 20.0 // (mm/sec) Must be same as XY for delta
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -832,26 +856,6 @@
// Delta only homes to Z // Delta only homes to Z
#define HOMING_FEEDRATE_Z (200*60) #define HOMING_FEEDRATE_Z (200*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
// delta speeds must be the same on xyz
#define DEFAULT_AXIS_STEPS_PER_UNIT {80, 80, 80, 760*1.1} // default steps per unit for Kossel (GT2, 20 tooth)
#define DEFAULT_MAX_FEEDRATE {500, 500, 500, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 20.0 // (mm/sec) Must be same as XY for delta
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -472,9 +472,33 @@
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
// delta speeds must be the same on xyz
#define DEFAULT_AXIS_STEPS_PER_UNIT {80, 80, 80, 760*1.1} // default steps per unit for Kossel (GT2, 20 tooth)
#define DEFAULT_MAX_FEEDRATE {500, 500, 500, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 20.0 // (mm/sec) Must be same as XY for delta
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -835,26 +859,6 @@
// Delta only homes to Z // Delta only homes to Z
#define HOMING_FEEDRATE_Z (200*60) #define HOMING_FEEDRATE_Z (200*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
// delta speeds must be the same on xyz
#define DEFAULT_AXIS_STEPS_PER_UNIT {80, 80, 80, 760*1.1} // default steps per unit for Kossel (GT2, 20 tooth)
#define DEFAULT_MAX_FEEDRATE {500, 500, 500, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 20.0 // (mm/sec) Must be same as XY for delta
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -461,9 +461,40 @@
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define XYZ_FULL_STEPS_PER_ROTATION 200
#define XYZ_MICROSTEPS 32
#define XYZ_BELT_PITCH 2
#define XYZ_PULLEY_TEETH 20
// delta speeds must be the same on xyz
#define XYZ_STEPS ((XYZ_FULL_STEPS_PER_ROTATION) * (XYZ_MICROSTEPS) / double(XYZ_BELT_PITCH) / double(XYZ_PULLEY_TEETH))
#define DEFAULT_AXIS_STEPS_PER_UNIT {XYZ_STEPS, XYZ_STEPS, XYZ_STEPS, 184.8}
#define DEFAULT_MAX_FEEDRATE {200, 200, 200, 200} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,9000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 20.0 // (mm/sec) Must be same as XY for delta
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -829,33 +860,6 @@
// Delta only homes to Z // Delta only homes to Z
#define HOMING_FEEDRATE_Z (200*60) #define HOMING_FEEDRATE_Z (200*60)
//
// MOVEMENT SETTINGS
// @section motion
//
#define XYZ_FULL_STEPS_PER_ROTATION 200
#define XYZ_MICROSTEPS 32
#define XYZ_BELT_PITCH 2
#define XYZ_PULLEY_TEETH 20
#define XYZ_STEPS ((XYZ_FULL_STEPS_PER_ROTATION) * (XYZ_MICROSTEPS) / double(XYZ_BELT_PITCH) / double(XYZ_PULLEY_TEETH))
// default settings
// delta speeds must be the same on xyz
#define DEFAULT_AXIS_STEPS_PER_UNIT {XYZ_STEPS, XYZ_STEPS, XYZ_STEPS, 184.8}
#define DEFAULT_MAX_FEEDRATE {200, 200, 200, 200} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,9000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 20.0 // (mm/sec) Must be same as XY for delta
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================
//============================================================================= //=============================================================================

View file

@ -470,9 +470,41 @@
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
// variables to calculate steps
#define XYZ_FULL_STEPS_PER_ROTATION 200
#define XYZ_MICROSTEPS 16
#define XYZ_BELT_PITCH 2
#define XYZ_PULLEY_TEETH 16
// delta speeds must be the same on xyz
#define XYZ_STEPS (XYZ_FULL_STEPS_PER_ROTATION * XYZ_MICROSTEPS / double(XYZ_BELT_PITCH) / double(XYZ_PULLEY_TEETH))
#define DEFAULT_AXIS_STEPS_PER_UNIT {XYZ_STEPS, XYZ_STEPS, XYZ_STEPS, 158} // default steps per unit for PowerWasp
#define DEFAULT_MAX_FEEDRATE {200, 200, 200, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 2000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 20.0 // (mm/sec)
#define DEFAULT_EJERK 20.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -829,35 +861,6 @@
// Delta only homes to Z // Delta only homes to Z
#define HOMING_FEEDRATE_Z (60*60) #define HOMING_FEEDRATE_Z (60*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// variables to calculate steps
#define XYZ_FULL_STEPS_PER_ROTATION 200
#define XYZ_MICROSTEPS 16
#define XYZ_BELT_PITCH 2
#define XYZ_PULLEY_TEETH 16
// delta speeds must be the same on xyz
#define XYZ_STEPS (XYZ_FULL_STEPS_PER_ROTATION * XYZ_MICROSTEPS / double(XYZ_BELT_PITCH) / double(XYZ_PULLEY_TEETH))
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {XYZ_STEPS, XYZ_STEPS, XYZ_STEPS, 158} // default steps per unit for PowerWasp
#define DEFAULT_MAX_FEEDRATE {200, 200, 200, 25} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {9000,9000,9000,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 2000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 20.0 // (mm/sec)
#define DEFAULT_EJERK 20.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -433,9 +433,32 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
#define DEFAULT_AXIS_STEPS_PER_UNIT {400, 400, 400, 163} // default steps per unit for ***** MakiBox A6 *****
#define DEFAULT_MAX_FEEDRATE {60, 60, 20, 45} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {2000,2000,30,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -748,26 +771,6 @@
#define HOMING_FEEDRATE_XY 1500 #define HOMING_FEEDRATE_XY 1500
#define HOMING_FEEDRATE_Z (2*60) #define HOMING_FEEDRATE_Z (2*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
#define DEFAULT_AXIS_STEPS_PER_UNIT {400, 400, 400, 163} // default steps per unit for ***** MakiBox A6 *****
#define DEFAULT_MAX_FEEDRATE {60, 60, 20, 45} // (mm/sec)
#define DEFAULT_MAX_ACCELERATION {2000,2000,30,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
#define DEFAULT_ACCELERATION 3000 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 3000 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================

View file

@ -420,9 +420,36 @@
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
#define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop. #define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
//=============================================================================
//============================== Movement Settings ============================
//=============================================================================
// @section motion
//#define DEFAULT_AXIS_STEPS_PER_UNIT {79.87, 79.87, 2566, 563,78} // Al's TVRR
//#define DEFAULT_AXIS_STEPS_PER_UNIT {81.26, 80.01, 2561, 599.14} // Michel TVRR old
//#define DEFAULT_AXIS_STEPS_PER_UNIT {71.1, 71.1, 2560, 739.65} // Michel TVRR
#define DEFAULT_AXIS_STEPS_PER_UNIT {71.1, 71.1, 2560, 600} // David TVRR
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 45} // (mm/sec) David TVRR
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
/* MICHEL: This has an impact on the "ripples" in print walls */
#define DEFAULT_ACCELERATION 500 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 500 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// "Jerk" specifies the minumum speed change that requires acceleration.
// When changing speed and direction, if the difference is less than the
// value set here, it may happen instantaneously.
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//=========================================================================== //===========================================================================
//============================= Z Probe Options ============================= //============================= Z Probe Options =============================
//=========================================================================== //===========================================================================
// @section probes
// //
// Probe Type // Probe Type
@ -735,30 +762,6 @@
#define HOMING_FEEDRATE_XY (50*60) #define HOMING_FEEDRATE_XY (50*60)
#define HOMING_FEEDRATE_Z (4*60) #define HOMING_FEEDRATE_Z (4*60)
//
// MOVEMENT SETTINGS
// @section motion
//
// default settings
//#define DEFAULT_AXIS_STEPS_PER_UNIT {79.87, 79.87, 2566, 563,78} // Al's TVRR
//#define DEFAULT_AXIS_STEPS_PER_UNIT {81.26, 80.01, 2561, 599.14} // Michel TVRR old
//#define DEFAULT_AXIS_STEPS_PER_UNIT {71.1, 71.1, 2560, 739.65} // Michel TVRR
#define DEFAULT_AXIS_STEPS_PER_UNIT {71.1, 71.1, 2560, 600} // David TVRR
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 45} // (mm/sec) David TVRR
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
/* MICHEL: This has an impact on the "ripples" in print walls */
#define DEFAULT_ACCELERATION 500 // X, Y, Z and E acceleration in mm/s^2 for printing moves
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
#define DEFAULT_TRAVEL_ACCELERATION 500 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
#define DEFAULT_XYJERK 20.0 // (mm/sec)
#define DEFAULT_ZJERK 0.4 // (mm/sec)
#define DEFAULT_EJERK 5.0 // (mm/sec)
//============================================================================= //=============================================================================
//============================= Additional Features =========================== //============================= Additional Features ===========================