Add comments about RAMPS 5V rail for servos.
This commit is contained in:
parent
d69822ed51
commit
5b8b939a1f
|
@ -276,6 +276,13 @@ The first define tells firmware how many servos you have.
|
||||||
The second tells what axis this servo will be attached to. In the example above, we have a servo in Z axis.
|
The second tells what axis this servo will be attached to. In the example above, we have a servo in Z axis.
|
||||||
The third one tells the angle in 2 situations: Probing (165º) and resting (60º). Check this with command M280 P0 S{angle} (example: M280 P0 S60 moves the servo to 60º)
|
The third one tells the angle in 2 situations: Probing (165º) and resting (60º). Check this with command M280 P0 S{angle} (example: M280 P0 S60 moves the servo to 60º)
|
||||||
|
|
||||||
|
*For RAMPS users:*
|
||||||
|
By default, RAMPS have no power on servo bus (if you happen to have a multimeter, check the voltage on servo power pins).
|
||||||
|
In order to get the servo working, you need to supply 5V to 5V pin.. You can do it using your power supply (if it has a 5V output) or jumping the "Vcc" from Arduino to the 5V RAMPS rail.
|
||||||
|
These 2 pins are located just between the Reset Button and the yellow fuses... There are marks in the board showing 5V and VCC.. just connect them..
|
||||||
|
If jumping the arduino Vcc do RAMPS 5V rail, take care to not use a power hungry servo, otherwise you will cause a blackout in the arduino board ;-)
|
||||||
|
|
||||||
|
|
||||||
Next you need to define the Z endstop (probe) offset from hotend.
|
Next you need to define the Z endstop (probe) offset from hotend.
|
||||||
My preferred method:
|
My preferred method:
|
||||||
|
|
||||||
|
|