Fix UBL manual mesh adjust behavior (#20248)

This commit is contained in:
Jason Smith 2020-11-22 16:20:33 -08:00 committed by Scott Lahteine
parent 28cd6eca88
commit 5e57e60692

View file

@ -949,7 +949,7 @@
g29_repetition_cnt = 1; // do exactly one mesh location. Otherwise use what the parser decided.
#if ENABLED(UBL_MESH_EDIT_MOVES_Z)
const float h_offset = parser.seenval('H') ? parser.value_linear_units() : 0;
const float h_offset = parser.seenval('H') ? parser.value_linear_units() : MANUAL_PROBE_START_Z;
if (!WITHIN(h_offset, 0, 10)) {
SERIAL_ECHOLNPGM("Offset out of bounds. (0 to 10mm)\n");
return;
@ -970,8 +970,6 @@
do_blocking_move_to_xy_z(pos, Z_CLEARANCE_BETWEEN_PROBES); // Move to the given XY with probe clearance
TERN_(UBL_MESH_EDIT_MOVES_Z, do_blocking_move_to_z(h_offset)); // Move Z to the given 'H' offset
MeshFlags done_flags{0};
const xy_int8_t &lpos = location.pos;
do {