Move delta ABL sanity checks up
This commit is contained in:
parent
db0882d068
commit
655c3fd55f
|
@ -202,11 +202,9 @@
|
|||
#if ENABLED(MESH_BED_LEVELING)
|
||||
#if ENABLED(DELTA)
|
||||
#error "MESH_BED_LEVELING does not yet support DELTA printers."
|
||||
#endif
|
||||
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
|
||||
#elif ENABLED(AUTO_BED_LEVELING_FEATURE)
|
||||
#error "Select AUTO_BED_LEVELING_FEATURE or MESH_BED_LEVELING, not both."
|
||||
#endif
|
||||
#if MESH_NUM_X_POINTS > 7 || MESH_NUM_Y_POINTS > 7
|
||||
#elif MESH_NUM_X_POINTS > 7 || MESH_NUM_Y_POINTS > 7
|
||||
#error "MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS need to be less than 8."
|
||||
#endif
|
||||
#elif ENABLED(MANUAL_BED_LEVELING)
|
||||
|
@ -219,6 +217,10 @@
|
|||
|
||||
#if PROBE_SELECTED
|
||||
|
||||
#if ENABLED(Z_PROBE_SLED) && ENABLED(DELTA)
|
||||
#error "You cannot use Z_PROBE_SLED with DELTA."
|
||||
#endif
|
||||
|
||||
/**
|
||||
* NUM_SERVOS is required for a Z servo probe
|
||||
*/
|
||||
|
@ -326,6 +328,13 @@
|
|||
*/
|
||||
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
|
||||
|
||||
/**
|
||||
* Delta has limited bed leveling options
|
||||
*/
|
||||
#if ENABLED(DELTA) && DISABLED(AUTO_BED_LEVELING_GRID)
|
||||
#error "You must use AUTO_BED_LEVELING_GRID for DELTA bed leveling."
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Require a Z min pin
|
||||
*/
|
||||
|
@ -410,25 +419,6 @@
|
|||
#error "Only enable one SAV_3DGLCD display type: U8GLIB_SSD1306 or U8GLIB_SH1106."
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Delta has limited bed leveling options
|
||||
*/
|
||||
#if ENABLED(DELTA)
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
|
||||
|
||||
#if DISABLED(AUTO_BED_LEVELING_GRID)
|
||||
#error "Only AUTO_BED_LEVELING_GRID is supported with DELTA."
|
||||
#endif
|
||||
|
||||
#if ENABLED(Z_PROBE_SLED)
|
||||
#error "You cannot use Z_PROBE_SLED with DELTA."
|
||||
#endif
|
||||
|
||||
#endif
|
||||
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Don't set more than one kinematic type
|
||||
*/
|
||||
|
|
Loading…