🔧 Move LASER_COOLANT_FLOW_METER to LASER_FEATURE

This commit is contained in:
Scott Lahteine 2022-05-05 11:47:08 -05:00
parent aa4c991755
commit 8f0180802a

View file

@ -249,20 +249,6 @@
#endif
#endif
//
// Laser Coolant Flow Meter
//
//#define LASER_COOLANT_FLOW_METER
#if ENABLED(LASER_COOLANT_FLOW_METER)
#define FLOWMETER_PIN 20 // Requires an external interrupt-enabled pin (e.g., RAMPS 2,3,18,19,20,21)
#define FLOWMETER_PPL 5880 // (pulses/liter) Flow meter pulses-per-liter on the input pin
#define FLOWMETER_INTERVAL 1000 // (ms) Flow rate calculation interval in milliseconds
#define FLOWMETER_SAFETY // Prevent running the laser without the minimum flow rate set below
#if ENABLED(FLOWMETER_SAFETY)
#define FLOWMETER_MIN_LITERS_PER_MINUTE 1.5 // (liters/min) Minimum flow required when enabled
#endif
#endif
/**
* Thermal Protection provides additional protection to your printer from damage
* and fire. Marlin always includes safe min and max temperature ranges which
@ -3627,6 +3613,20 @@
#define I2C_AMMETER_SHUNT_RESISTOR 0.1 // (Ohms) Calibration shunt resistor value
#endif
//
// Laser Coolant Flow Meter
//
//#define LASER_COOLANT_FLOW_METER
#if ENABLED(LASER_COOLANT_FLOW_METER)
#define FLOWMETER_PIN 20 // Requires an external interrupt-enabled pin (e.g., RAMPS 2,3,18,19,20,21)
#define FLOWMETER_PPL 5880 // (pulses/liter) Flow meter pulses-per-liter on the input pin
#define FLOWMETER_INTERVAL 1000 // (ms) Flow rate calculation interval in milliseconds
#define FLOWMETER_SAFETY // Prevent running the laser without the minimum flow rate set below
#if ENABLED(FLOWMETER_SAFETY)
#define FLOWMETER_MIN_LITERS_PER_MINUTE 1.5 // (liters/min) Minimum flow required when enabled
#endif
#endif
#endif
#endif // SPINDLE_FEATURE || LASER_FEATURE