Fix bug which can cause an infinite M109 loop
Since residency_start_ms is -1 when entering the heatup while loop whilst the hotend temp is close to the target them already then it may not escape. Hence "Start the TEMP_RESIDENCY_TIME timer when we reach target temp for the first time."
This commit is contained in:
parent
3ecf38d32e
commit
907aed57db
|
@ -4325,7 +4325,8 @@ inline void gcode_M109() {
|
|||
#ifdef TEMP_RESIDENCY_TIME
|
||||
// Start the TEMP_RESIDENCY_TIME timer when we reach target temp for the first time.
|
||||
// Restart the timer whenever the temperature falls outside the hysteresis.
|
||||
if (labs(degHotend(target_extruder) - degTargetHotend(target_extruder)) > ((residency_start_ms < 0) ? TEMP_WINDOW : TEMP_HYSTERESIS))
|
||||
if ((residency_start_ms <= 0 && labs(degHotend(target_extruder) - degTargetHotend(target_extruder)) < TEMP_WINDOW) ||
|
||||
(labs(degHotend(target_extruder) - degTargetHotend(target_extruder)) > ((residency_start_ms < 0) ? TEMP_WINDOW : TEMP_HYSTERESIS)))
|
||||
residency_start_ms = millis();
|
||||
#endif //TEMP_RESIDENCY_TIME
|
||||
|
||||
|
|
Loading…