Fix erroneous reference to temperature in time calculations
Travis is having problems at: https://github.com/MarlinFirmware/Marlin/pull/8560 So... doing a direct commit to get things correct. Bugfix_v1.1.x does not have this bug. Nothing needs to be done to that branch.
This commit is contained in:
parent
d24b1190bd
commit
d29cb646e3
|
@ -248,7 +248,7 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
||||||
;
|
;
|
||||||
const int8_t watch_temp_period =
|
const int8_t watch_temp_period =
|
||||||
#if ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED) && ENABLED(THERMAL_PROTECTION_HOTENDS) && ENABLED(PIDTEMP)
|
#if ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED) && ENABLED(THERMAL_PROTECTION_HOTENDS) && ENABLED(PIDTEMP)
|
||||||
hotend < 0 ? temp - THERMAL_PROTECTION_BED_PERIOD : THERMAL_PROTECTION_PERIOD
|
hotend < 0 ? THERMAL_PROTECTION_BED_PERIOD : THERMAL_PROTECTION_PERIOD
|
||||||
#elif ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED)
|
#elif ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED)
|
||||||
THERMAL_PROTECTION_BED_PERIOD
|
THERMAL_PROTECTION_BED_PERIOD
|
||||||
#else
|
#else
|
||||||
|
|