Fix erroneous reference to temperature in time calculations
Travis is having problems at: https://github.com/MarlinFirmware/Marlin/pull/8560 So... doing a direct commit to get things correct. Bugfix_v1.1.x does not have this bug. Nothing needs to be done to that branch.
This commit is contained in:
parent
d24b1190bd
commit
d29cb646e3
|
@ -248,7 +248,7 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS],
|
|||
;
|
||||
const int8_t watch_temp_period =
|
||||
#if ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED) && ENABLED(THERMAL_PROTECTION_HOTENDS) && ENABLED(PIDTEMP)
|
||||
hotend < 0 ? temp - THERMAL_PROTECTION_BED_PERIOD : THERMAL_PROTECTION_PERIOD
|
||||
hotend < 0 ? THERMAL_PROTECTION_BED_PERIOD : THERMAL_PROTECTION_PERIOD
|
||||
#elif ENABLED(THERMAL_PROTECTION_BED) && ENABLED(PIDTEMPBED)
|
||||
THERMAL_PROTECTION_BED_PERIOD
|
||||
#else
|
||||
|
|
Loading…
Reference in a new issue