🎨 Combine M104/M109 and M140/M190 code
This commit is contained in:
parent
f60965a107
commit
e573611021
|
@ -648,8 +648,9 @@ private:
|
|||
#endif
|
||||
|
||||
#if HAS_EXTRUDERS
|
||||
static void M104();
|
||||
static void M109();
|
||||
static void M104_M109(const bool isM109);
|
||||
FORCE_INLINE static void M104() { M104_M109(false); }
|
||||
FORCE_INLINE static void M109() { M104_M109(true); }
|
||||
#endif
|
||||
|
||||
static void M105();
|
||||
|
@ -699,8 +700,9 @@ private:
|
|||
#endif
|
||||
|
||||
#if HAS_HEATED_BED
|
||||
static void M140();
|
||||
static void M190();
|
||||
static void M140_M190(const bool isM190);
|
||||
FORCE_INLINE static void M140() { M140_M190(false); }
|
||||
FORCE_INLINE static void M190() { M140_M190(true); }
|
||||
#endif
|
||||
|
||||
#if HAS_HEATED_CHAMBER
|
||||
|
|
|
@ -51,89 +51,29 @@
|
|||
|
||||
/**
|
||||
* M104: Set Hotend Temperature target and return immediately
|
||||
*
|
||||
* Parameters:
|
||||
* I<preset> : Material Preset index (if material presets are defined)
|
||||
* T<index> : Tool index. If omitted, applies to the active tool
|
||||
* S<target> : The target temperature in current units
|
||||
*/
|
||||
void GcodeSuite::M104() {
|
||||
|
||||
if (DEBUGGING(DRYRUN)) return;
|
||||
|
||||
#if ENABLED(MIXING_EXTRUDER) && MIXING_VIRTUAL_TOOLS > 1
|
||||
constexpr int8_t target_extruder = 0;
|
||||
#else
|
||||
const int8_t target_extruder = get_target_extruder_from_command();
|
||||
if (target_extruder < 0) return;
|
||||
#endif
|
||||
|
||||
bool got_temp = false;
|
||||
celsius_t temp = 0;
|
||||
|
||||
// Accept 'I' if temperature presets are defined
|
||||
#if PREHEAT_COUNT
|
||||
got_temp = parser.seenval('I');
|
||||
if (got_temp) {
|
||||
const uint8_t index = parser.value_byte();
|
||||
temp = ui.material_preset[_MIN(index, PREHEAT_COUNT - 1)].hotend_temp;
|
||||
}
|
||||
#endif
|
||||
|
||||
// If no 'I' get the temperature from 'S'
|
||||
if (!got_temp) {
|
||||
got_temp = parser.seenval('S');
|
||||
if (got_temp) temp = parser.value_celsius();
|
||||
}
|
||||
|
||||
if (got_temp) {
|
||||
#if ENABLED(SINGLENOZZLE_STANDBY_TEMP)
|
||||
thermalManager.singlenozzle_temp[target_extruder] = temp;
|
||||
if (target_extruder != active_extruder) return;
|
||||
#endif
|
||||
thermalManager.setTargetHotend(temp, target_extruder);
|
||||
|
||||
#if ENABLED(DUAL_X_CARRIAGE)
|
||||
if (idex_is_duplicating() && target_extruder == 0)
|
||||
thermalManager.setTargetHotend(temp ? temp + duplicate_extruder_temp_offset : 0, 1);
|
||||
#endif
|
||||
|
||||
#if ENABLED(PRINTJOB_TIMER_AUTOSTART)
|
||||
/**
|
||||
* Stop the timer at the end of print. Start is managed by 'heat and wait' M109.
|
||||
* Hotends use EXTRUDE_MINTEMP / 2 to allow nozzles to be put into hot standby
|
||||
* mode, for instance in a dual extruder setup, without affecting the running
|
||||
* print timer.
|
||||
*/
|
||||
thermalManager.auto_job_check_timer(false, true);
|
||||
#endif
|
||||
}
|
||||
|
||||
TERN_(AUTOTEMP, planner.autotemp_M104_M109());
|
||||
}
|
||||
|
||||
/**
|
||||
* M109: Set Hotend Temperature target and wait
|
||||
*
|
||||
* Parameters
|
||||
* I<preset> : Material Preset index (if material presets are defined)
|
||||
* T<index> : Tool index. If omitted, applies to the active tool
|
||||
* S<target> : The target temperature in current units. Wait for heating only.
|
||||
* R<target> : The target temperature in current units. Wait for heating and cooling.
|
||||
* S<target> : The target temperature in current units. For M109, only wait when heating up.
|
||||
*
|
||||
* With AUTOTEMP...
|
||||
* F<factor> : Autotemp Scaling Factor. Set non-zero to enable Auto-temp.
|
||||
* S<min> : Minimum temperature, in current units.
|
||||
* B<max> : Maximum temperature, in current units.
|
||||
*
|
||||
* M109 Parameters
|
||||
* R<target> : The target temperature in current units. Wait for heating and cooling.
|
||||
*
|
||||
* Examples
|
||||
* M109 S100 : Set target to 100°. Wait until the hotend is at or above 100°.
|
||||
* M104 S100 : Set target to 100° and return.
|
||||
* M109 R150 : Set target to 150°. Wait until the hotend gets close to 150°.
|
||||
*
|
||||
* With PRINTJOB_TIMER_AUTOSTART turning on heaters will start the print job timer
|
||||
* (used by printingIsActive, etc.) and turning off heaters will stop the timer.
|
||||
*/
|
||||
void GcodeSuite::M109() {
|
||||
void GcodeSuite::M104_M109(const bool isM109) {
|
||||
|
||||
if (DEBUGGING(DRYRUN)) return;
|
||||
|
||||
|
@ -160,7 +100,7 @@ void GcodeSuite::M109() {
|
|||
bool no_wait_for_cooling = false;
|
||||
if (!got_temp) {
|
||||
no_wait_for_cooling = parser.seenval('S');
|
||||
got_temp = no_wait_for_cooling || parser.seenval('R');
|
||||
got_temp = no_wait_for_cooling || (isM109 && parser.seenval('R'));
|
||||
if (got_temp) temp = parser.value_celsius();
|
||||
}
|
||||
|
||||
|
@ -182,7 +122,7 @@ void GcodeSuite::M109() {
|
|||
* standby mode, (e.g., in a dual extruder setup) without affecting
|
||||
* the running print timer.
|
||||
*/
|
||||
thermalManager.auto_job_check_timer(true, true);
|
||||
thermalManager.auto_job_check_timer(isM109, true);
|
||||
#endif
|
||||
|
||||
#if HAS_STATUS_MESSAGE
|
||||
|
@ -193,7 +133,7 @@ void GcodeSuite::M109() {
|
|||
|
||||
TERN_(AUTOTEMP, planner.autotemp_M104_M109());
|
||||
|
||||
if (got_temp)
|
||||
if (isM109 && got_temp)
|
||||
(void)thermalManager.wait_for_hotend(target_extruder, no_wait_for_cooling);
|
||||
}
|
||||
|
||||
|
|
|
@ -35,62 +35,28 @@
|
|||
#include "../../lcd/marlinui.h"
|
||||
|
||||
/**
|
||||
* M140: Set bed temperature
|
||||
* M140 - Set Bed Temperature target and return immediately
|
||||
* M190 - Set Bed Temperature target and wait
|
||||
*
|
||||
* I<index> : Preset index (if material presets are defined)
|
||||
* S<target> : The target temperature in current units
|
||||
*/
|
||||
void GcodeSuite::M140() {
|
||||
if (DEBUGGING(DRYRUN)) return;
|
||||
|
||||
bool got_temp = false;
|
||||
celsius_t temp = 0;
|
||||
|
||||
// Accept 'I' if temperature presets are defined
|
||||
#if PREHEAT_COUNT
|
||||
got_temp = parser.seenval('I');
|
||||
if (got_temp) {
|
||||
const uint8_t index = parser.value_byte();
|
||||
temp = ui.material_preset[_MIN(index, PREHEAT_COUNT - 1)].bed_temp;
|
||||
}
|
||||
#endif
|
||||
|
||||
// If no 'I' get the temperature from 'S'
|
||||
if (!got_temp) {
|
||||
got_temp = parser.seenval('S');
|
||||
if (got_temp) temp = parser.value_celsius();
|
||||
}
|
||||
|
||||
if (got_temp) {
|
||||
thermalManager.setTargetBed(temp);
|
||||
|
||||
#if ENABLED(PRINTJOB_TIMER_AUTOSTART)
|
||||
/**
|
||||
* Stop the timer at the end of print. Hotend, bed target, and chamber
|
||||
* temperatures need to be set below mintemp. Order of M140, M104, and M141
|
||||
* at the end of the print does not matter.
|
||||
*/
|
||||
thermalManager.auto_job_check_timer(false, true);
|
||||
#endif
|
||||
}
|
||||
}
|
||||
|
||||
/**
|
||||
* M190 - Set Bed Temperature target and wait
|
||||
*
|
||||
* Parameters:
|
||||
* Parameters
|
||||
* I<index> : Preset index (if material presets are defined)
|
||||
* S<target> : The target temperature in current units. Wait for heating only.
|
||||
*
|
||||
* M190 Parameters
|
||||
* R<target> : The target temperature in current units. Wait for heating and cooling.
|
||||
*
|
||||
* Examples:
|
||||
* M190 S60 : Set target to 60°. Wait until the bed is at or above 60°.
|
||||
* Examples
|
||||
* M140 S60 : Set target to 60° and return right away.
|
||||
* M190 R40 : Set target to 40°. Wait until the bed gets close to 40°.
|
||||
*
|
||||
* With PRINTJOB_TIMER_AUTOSTART turning on heaters will start the print job timer
|
||||
* (used by printingIsActive, etc.) and turning off heaters will stop the timer.
|
||||
*/
|
||||
void GcodeSuite::M190() {
|
||||
void GcodeSuite::M140_M190(const bool isM190) {
|
||||
|
||||
if (DEBUGGING(DRYRUN)) return;
|
||||
|
||||
bool got_temp = false;
|
||||
|
@ -109,7 +75,7 @@ void GcodeSuite::M190() {
|
|||
bool no_wait_for_cooling = false;
|
||||
if (!got_temp) {
|
||||
no_wait_for_cooling = parser.seenval('S');
|
||||
got_temp = no_wait_for_cooling || parser.seenval('R');
|
||||
got_temp = no_wait_for_cooling || (isM190 && parser.seenval('R'));
|
||||
if (got_temp) temp = parser.value_celsius();
|
||||
}
|
||||
|
||||
|
@ -121,7 +87,8 @@ void GcodeSuite::M190() {
|
|||
|
||||
ui.set_status_P(thermalManager.isHeatingBed() ? GET_TEXT(MSG_BED_HEATING) : GET_TEXT(MSG_BED_COOLING));
|
||||
|
||||
thermalManager.wait_for_bed(no_wait_for_cooling);
|
||||
if (isM190)
|
||||
thermalManager.wait_for_bed(no_wait_for_cooling);
|
||||
}
|
||||
|
||||
#endif // HAS_HEATED_BED
|
||||
|
|
Loading…
Reference in a new issue