Fixed Z-Probes NO/NC for Anycubic Kossel (#12083)
This commit is contained in:
parent
ab9d5eb38d
commit
ea13a77dcb
|
@ -700,7 +700,7 @@
|
|||
// Mechanical endstop with COM to ground and NC to Signal uses "false" here (most common setup).
|
||||
#define X_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Y_MIN_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Z_MIN_ENDSTOP_INVERTING (ANYCUBIC_PROBE_VERSION + 0 == 2) // V1 is NC, V2 is NO
|
||||
#define Z_MIN_ENDSTOP_INVERTING (ANYCUBIC_PROBE_VERSION + 0 == 1) // V1 is NO, V2 is NC
|
||||
#define X_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Y_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
#define Z_MAX_ENDSTOP_INVERTING false // set to true to invert the logic of the endstop.
|
||||
|
|