Merge pull request #6050 from thinkyhead/rc_probe_manually
Add PROBE_MANUALLY — ABL without a probe
This commit is contained in:
commit
f75aa4d5be
21
.travis.yml
21
.travis.yml
|
@ -124,24 +124,17 @@ script:
|
|||
- build_marlin
|
||||
#
|
||||
# Test a Sled Z Probe
|
||||
#
|
||||
- restore_configs
|
||||
- opt_enable Z_PROBE_SLED
|
||||
- build_marlin
|
||||
#
|
||||
# ...with AUTO_BED_LEVELING_LINEAR, DEBUG_LEVELING_FEATURE, EEPROM_SETTINGS, and EEPROM_CHITCHAT
|
||||
#
|
||||
- opt_enable AUTO_BED_LEVELING_LINEAR DEBUG_LEVELING_FEATURE EEPROM_SETTINGS EEPROM_CHITCHAT
|
||||
- restore_configs
|
||||
- opt_enable Z_PROBE_SLED AUTO_BED_LEVELING_LINEAR DEBUG_LEVELING_FEATURE EEPROM_SETTINGS EEPROM_CHITCHAT
|
||||
- build_marlin
|
||||
#
|
||||
# Test a Servo Probe
|
||||
# ...with AUTO_BED_LEVELING_3POINT, DEBUG_LEVELING_FEATURE, EEPROM_SETTINGS, EEPROM_CHITCHAT, EXTENDED_CAPABILITIES_REPORT, and AUTO_REPORT_TEMPERATURES
|
||||
#
|
||||
- restore_configs
|
||||
- opt_enable NUM_SERVOS Z_ENDSTOP_SERVO_NR Z_SERVO_ANGLES DEACTIVATE_SERVOS_AFTER_MOVE
|
||||
- build_marlin
|
||||
#
|
||||
# ...with AUTO_BED_LEVELING_3POINT, DEBUG_LEVELING_FEATURE, EEPROM_SETTINGS, EEPROM_CHITCHAT, EXTENDED_CAPABILITIES_REPORT, and AUTO_REPORT_TEMPERATURES
|
||||
#
|
||||
- opt_enable AUTO_BED_LEVELING_3POINT DEBUG_LEVELING_FEATURE EEPROM_SETTINGS EEPROM_CHITCHAT
|
||||
- opt_enable_adv EXTENDED_CAPABILITIES_REPORT AUTO_REPORT_TEMPERATURES
|
||||
- build_marlin
|
||||
|
@ -149,7 +142,13 @@ script:
|
|||
# Test MESH_BED_LEVELING feature, with LCD
|
||||
#
|
||||
- restore_configs
|
||||
- opt_enable MESH_BED_LEVELING MESH_G28_REST_ORIGIN MANUAL_BED_LEVELING ULTIMAKERCONTROLLER
|
||||
- opt_enable MESH_BED_LEVELING MESH_G28_REST_ORIGIN LCD_BED_LEVELING ULTIMAKERCONTROLLER
|
||||
- build_marlin
|
||||
#
|
||||
# Test PROBE_MANUALLY feature, with LCD support
|
||||
#
|
||||
- restore_configs
|
||||
- opt_enable PROBE_MANUALLY AUTO_BED_LEVELING_BILINEAR LCD_BED_LEVELING ULTIMAKERCONTROLLER
|
||||
- build_marlin
|
||||
#
|
||||
# Test EEPROM_SETTINGS, EEPROM_CHITCHAT, M100_FREE_MEMORY_WATCHER,
|
||||
|
|
|
@ -371,12 +371,12 @@
|
|||
/**
|
||||
* Set a flag for any enabled probe
|
||||
*/
|
||||
#define PROBE_SELECTED (ENABLED(FIX_MOUNTED_PROBE) || ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED))
|
||||
#define PROBE_SELECTED (ENABLED(PROBE_MANUALLY) || ENABLED(FIX_MOUNTED_PROBE) || ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED))
|
||||
|
||||
/**
|
||||
* Clear probe pin settings when no probe is selected
|
||||
*/
|
||||
#if !PROBE_SELECTED
|
||||
#if !PROBE_SELECTED || ENABLED(PROBE_MANUALLY)
|
||||
#undef Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN
|
||||
#undef Z_MIN_PROBE_ENDSTOP
|
||||
#endif
|
||||
|
|
|
@ -589,7 +589,7 @@
|
|||
|
||||
#define PROBE_PIN_CONFIGURED (HAS_Z_MIN_PROBE_PIN || (HAS_Z_MIN && ENABLED(Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN)))
|
||||
|
||||
#define HAS_BED_PROBE (PROBE_SELECTED && PROBE_PIN_CONFIGURED)
|
||||
#define HAS_BED_PROBE (PROBE_SELECTED && PROBE_PIN_CONFIGURED && DISABLED(PROBE_MANUALLY))
|
||||
|
||||
#if ENABLED(Z_PROBE_ALLEN_KEY)
|
||||
#define PROBE_IS_TRIGGERED_WHEN_STOWED_TEST
|
||||
|
|
|
@ -545,6 +545,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -876,15 +881,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1432,13 +1441,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -353,10 +353,10 @@ static long gcode_N, gcode_LastN, Stopped_gcode_LastN = 0;
|
|||
* the main loop. The process_next_command function parses the next
|
||||
* command and hands off execution to individual handler functions.
|
||||
*/
|
||||
static char command_queue[BUFSIZE][MAX_CMD_SIZE];
|
||||
uint8_t commands_in_queue = 0; // Count of commands in the queue
|
||||
static uint8_t cmd_queue_index_r = 0, // Ring buffer read position
|
||||
cmd_queue_index_w = 0, // Ring buffer write position
|
||||
commands_in_queue = 0; // Count of commands in the queue
|
||||
cmd_queue_index_w = 0; // Ring buffer write position
|
||||
static char command_queue[BUFSIZE][MAX_CMD_SIZE];
|
||||
|
||||
/**
|
||||
* Current GCode Command
|
||||
|
@ -3502,6 +3502,12 @@ inline void gcode_G4() {
|
|||
|
||||
#endif // Z_SAFE_HOMING
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
bool g29_in_progress = false;
|
||||
#else
|
||||
constexpr bool g29_in_progress = false;
|
||||
#endif
|
||||
|
||||
/**
|
||||
* G28: Home all axes according to settings
|
||||
*
|
||||
|
@ -3529,6 +3535,11 @@ inline void gcode_G28() {
|
|||
// Wait for planner moves to finish!
|
||||
stepper.synchronize();
|
||||
|
||||
// Cancel the active G29 session
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
g29_in_progress = false;
|
||||
#endif
|
||||
|
||||
// Disable the leveling matrix before homing
|
||||
#if PLANNER_LEVELING
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
@ -3719,9 +3730,9 @@ inline void gcode_G28() {
|
|||
|
||||
#endif
|
||||
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
#if ENABLED(MESH_BED_LEVELING) || ENABLED(PROBE_MANUALLY)
|
||||
|
||||
inline void _mbl_goto_xy(const float &x, const float &y) {
|
||||
inline void _manual_goto_xy(const float &x, const float &y) {
|
||||
const float old_feedrate_mm_s = feedrate_mm_s;
|
||||
|
||||
#if MANUAL_PROBE_HEIGHT > 0
|
||||
|
@ -3745,6 +3756,10 @@ inline void gcode_G28() {
|
|||
stepper.synchronize();
|
||||
}
|
||||
|
||||
#endif
|
||||
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
|
||||
// Save 130 bytes with non-duplication of PSTR
|
||||
void say_not_entered() { SERIAL_PROTOCOLLNPGM(" not entered."); }
|
||||
|
||||
|
@ -3835,7 +3850,7 @@ inline void gcode_G28() {
|
|||
// If there's another point to sample, move there with optional lift.
|
||||
if (mbl_probe_index < (MESH_NUM_X_POINTS) * (MESH_NUM_Y_POINTS)) {
|
||||
mbl.zigzag(mbl_probe_index, px, py);
|
||||
_mbl_goto_xy(mbl.index_to_xpos[px], mbl.index_to_ypos[py]);
|
||||
_manual_goto_xy(mbl.index_to_xpos[px], mbl.index_to_ypos[py]);
|
||||
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
// Disable software endstops to allow manual adjustment
|
||||
|
@ -3917,50 +3932,86 @@ inline void gcode_G28() {
|
|||
|
||||
#elif HAS_ABL && DISABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
#if ABL_GRID
|
||||
#if ENABLED(PROBE_Y_FIRST)
|
||||
#define PR_OUTER_VAR xCount
|
||||
#define PR_OUTER_END abl_grid_points_x
|
||||
#define PR_INNER_VAR yCount
|
||||
#define PR_INNER_END abl_grid_points_y
|
||||
#else
|
||||
#define PR_OUTER_VAR yCount
|
||||
#define PR_OUTER_END abl_grid_points_y
|
||||
#define PR_INNER_VAR xCount
|
||||
#define PR_INNER_END abl_grid_points_x
|
||||
#endif
|
||||
#endif
|
||||
|
||||
/**
|
||||
* G29: Detailed Z probe, probes the bed at 3 or more points.
|
||||
* Will fail if the printer has not been homed with G28.
|
||||
*
|
||||
* Enhanced G29 Auto Bed Leveling Probe Routine
|
||||
*
|
||||
* Parameters With LINEAR and BILINEAR:
|
||||
*
|
||||
* P Set the size of the grid that will be probed (P x P points).
|
||||
* Not supported by non-linear delta printer bed leveling.
|
||||
* Example: "G29 P4"
|
||||
*
|
||||
* S Set the XY travel speed between probe points (in units/min)
|
||||
*
|
||||
* D Dry-Run mode. Just evaluate the bed Topology - Don't apply
|
||||
* or clean the rotation Matrix. Useful to check the topology
|
||||
* or alter the bed level data. Useful to check the topology
|
||||
* after a first run of G29.
|
||||
*
|
||||
* J Jettison current bed leveling data
|
||||
*
|
||||
* V Set the verbose level (0-4). Example: "G29 V3"
|
||||
*
|
||||
* Parameters With LINEAR leveling only:
|
||||
*
|
||||
* P Set the size of the grid that will be probed (P x P points).
|
||||
* Example: "G29 P4"
|
||||
*
|
||||
* X Set the X size of the grid that will be probed (X x Y points).
|
||||
* Example: "G29 X7 Y5"
|
||||
*
|
||||
* Y Set the Y size of the grid that will be probed (X x Y points).
|
||||
*
|
||||
* T Generate a Bed Topology Report. Example: "G29 P5 T" for a detailed report.
|
||||
* This is useful for manual bed leveling and finding flaws in the bed (to
|
||||
* assist with part placement).
|
||||
* Not supported by non-linear delta printer bed leveling.
|
||||
*
|
||||
* Parameters With LINEAR and BILINEAR leveling only:
|
||||
*
|
||||
* S Set the XY travel speed between probe points (in units/min)
|
||||
*
|
||||
* F Set the Front limit of the probing grid
|
||||
* B Set the Back limit of the probing grid
|
||||
* L Set the Left limit of the probing grid
|
||||
* R Set the Right limit of the probing grid
|
||||
*
|
||||
* Parameters with BILINEAR only:
|
||||
* Parameters with BILINEAR leveling only:
|
||||
*
|
||||
* Z Supply an additional Z probe offset
|
||||
*
|
||||
* Global Parameters:
|
||||
* Extra parameters with PROBE_MANUALLY:
|
||||
*
|
||||
* E/e By default G29 will engage the Z probe, test the bed, then disengage.
|
||||
* To do manual probing simply repeat G29 until the procedure is complete.
|
||||
* The first G29 accepts parameters. 'G29 Q' for status, 'G29 A' to abort.
|
||||
*
|
||||
* Q Query leveling and G29 state
|
||||
*
|
||||
* A Abort current leveling procedure
|
||||
*
|
||||
* W Write a mesh point. (Ignored during leveling.)
|
||||
* X Required X for mesh point
|
||||
* Y Required Y for mesh point
|
||||
* Z Required Z for mesh point
|
||||
*
|
||||
* Without PROBE_MANUALLY:
|
||||
*
|
||||
* E By default G29 will engage the Z probe, test the bed, then disengage.
|
||||
* Include "E" to engage/disengage the Z probe for each sample.
|
||||
* There's no extra effect if you have a fixed Z probe.
|
||||
* Usage: "G29 E" or "G29 e"
|
||||
*
|
||||
*/
|
||||
inline void gcode_G29() {
|
||||
|
||||
// G29 Q is also available if debugging
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
const bool query = code_seen('Q');
|
||||
const uint8_t old_debug_flags = marlin_debug_flags;
|
||||
|
@ -3970,37 +4021,148 @@ inline void gcode_G28() {
|
|||
log_machine_info();
|
||||
}
|
||||
marlin_debug_flags = old_debug_flags;
|
||||
#if DISABLED(PROBE_MANUALLY)
|
||||
if (query) return;
|
||||
#endif
|
||||
#endif
|
||||
|
||||
// Don't allow auto-leveling without homing first
|
||||
if (axis_unhomed_error(true, true, true)) return;
|
||||
|
||||
const int verbose_level = code_seen('V') ? code_value_int() : 1;
|
||||
if (verbose_level < 0 || verbose_level > 4) {
|
||||
// Define local vars 'static' for manual probing, 'auto' otherwise
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
#define ABL_VAR static
|
||||
#else
|
||||
#define ABL_VAR
|
||||
#endif
|
||||
|
||||
ABL_VAR int verbose_level, abl_probe_index;
|
||||
ABL_VAR float xProbe, yProbe, measured_z;
|
||||
ABL_VAR bool dryrun, abl_should_enable;
|
||||
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
ABL_VAR bool enable_soft_endstops = true;
|
||||
#endif
|
||||
|
||||
#if ABL_GRID
|
||||
ABL_VAR uint8_t PR_OUTER_VAR;
|
||||
ABL_VAR int8_t PR_INNER_VAR;
|
||||
ABL_VAR int left_probe_bed_position, right_probe_bed_position, front_probe_bed_position, back_probe_bed_position;
|
||||
ABL_VAR float xGridSpacing, yGridSpacing;
|
||||
|
||||
#define ABL_GRID_MAX (ABL_GRID_MAX_POINTS_X) * (ABL_GRID_MAX_POINTS_Y)
|
||||
|
||||
#if ABL_PLANAR
|
||||
ABL_VAR uint8_t abl_grid_points_x = ABL_GRID_MAX_POINTS_X,
|
||||
abl_grid_points_y = ABL_GRID_MAX_POINTS_Y;
|
||||
ABL_VAR int abl2;
|
||||
ABL_VAR bool do_topography_map;
|
||||
#else // 3-point
|
||||
uint8_t constexpr abl_grid_points_x = ABL_GRID_MAX_POINTS_X,
|
||||
abl_grid_points_y = ABL_GRID_MAX_POINTS_Y;
|
||||
|
||||
int constexpr abl2 = ABL_GRID_MAX;
|
||||
#endif
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
||||
|
||||
ABL_VAR float zoffset;
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
|
||||
ABL_VAR int indexIntoAB[ABL_GRID_MAX_POINTS_X][ABL_GRID_MAX_POINTS_Y];
|
||||
|
||||
ABL_VAR float eqnAMatrix[ABL_GRID_MAX * 3], // "A" matrix of the linear system of equations
|
||||
eqnBVector[ABL_GRID_MAX], // "B" vector of Z points
|
||||
mean;
|
||||
#endif
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// Probe at 3 arbitrary points
|
||||
ABL_VAR vector_3 points[3] = {
|
||||
vector_3(ABL_PROBE_PT_1_X, ABL_PROBE_PT_1_Y, 0),
|
||||
vector_3(ABL_PROBE_PT_2_X, ABL_PROBE_PT_2_Y, 0),
|
||||
vector_3(ABL_PROBE_PT_3_X, ABL_PROBE_PT_3_Y, 0)
|
||||
};
|
||||
|
||||
#endif // AUTO_BED_LEVELING_3POINT
|
||||
|
||||
/**
|
||||
* On the initial G29 fetch command parameters.
|
||||
*/
|
||||
if (!g29_in_progress) {
|
||||
|
||||
abl_probe_index = 0;
|
||||
abl_should_enable = planner.abl_enabled;
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
||||
|
||||
if (code_seen('W')) {
|
||||
if (!bilinear_grid_spacing[X_AXIS]) {
|
||||
SERIAL_ERROR_START;
|
||||
SERIAL_ERRORLNPGM("No bilinear grid");
|
||||
return;
|
||||
}
|
||||
|
||||
const float z = code_seen('Z') && code_has_value() ? code_value_float() : 99999;
|
||||
if (!WITHIN(z, -10, 10)) {
|
||||
SERIAL_ERROR_START;
|
||||
SERIAL_ERRORLNPGM("Bad Z value");
|
||||
return;
|
||||
}
|
||||
|
||||
const float x = code_seen('X') && code_has_value() ? code_value_float() : 99999,
|
||||
y = code_seen('Y') && code_has_value() ? code_value_float() : 99999;
|
||||
int8_t i = code_seen('I') && code_has_value() ? code_value_byte() : -1,
|
||||
j = code_seen('J') && code_has_value() ? code_value_byte() : -1;
|
||||
|
||||
if (x < 99998 && y < 99998) {
|
||||
// Get nearest i / j from x / y
|
||||
i = (x - LOGICAL_X_POSITION(bilinear_start[X_AXIS]) + 0.5 * xGridSpacing) / xGridSpacing;
|
||||
j = (y - LOGICAL_Y_POSITION(bilinear_start[Y_AXIS]) + 0.5 * yGridSpacing) / yGridSpacing;
|
||||
i = constrain(i, 0, ABL_GRID_MAX_POINTS_X - 1);
|
||||
j = constrain(j, 0, ABL_GRID_MAX_POINTS_Y - 1);
|
||||
}
|
||||
if (WITHIN(i, 0, ABL_GRID_MAX_POINTS_X - 1) && WITHIN(j, 0, ABL_GRID_MAX_POINTS_Y)) {
|
||||
set_bed_leveling_enabled(false);
|
||||
bed_level_grid[i][j] = z;
|
||||
#if ENABLED(ABL_BILINEAR_SUBDIVISION)
|
||||
bed_level_virt_interpolate();
|
||||
#endif
|
||||
set_bed_leveling_enabled(abl_should_enable);
|
||||
}
|
||||
return;
|
||||
} // code_seen('W')
|
||||
|
||||
#endif
|
||||
|
||||
#if PLANNER_LEVELING
|
||||
|
||||
// Jettison bed leveling data
|
||||
if (code_seen('J')) {
|
||||
reset_bed_level();
|
||||
return;
|
||||
}
|
||||
|
||||
#endif
|
||||
|
||||
verbose_level = code_seen('V') && code_has_value() ? code_value_int() : 0;
|
||||
if (!WITHIN(verbose_level, 0, 4)) {
|
||||
SERIAL_PROTOCOLLNPGM("?(V)erbose Level is implausible (0-4).");
|
||||
return;
|
||||
}
|
||||
|
||||
bool dryrun = code_seen('D'),
|
||||
stow_probe_after_each = code_seen('E');
|
||||
dryrun = code_seen('D') ? code_value_bool() : false;
|
||||
|
||||
#if ABL_GRID
|
||||
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
|
||||
if (verbose_level > 0) {
|
||||
SERIAL_PROTOCOLLNPGM("G29 Auto Bed Leveling");
|
||||
if (dryrun) SERIAL_PROTOCOLLNPGM("Running in DRY-RUN mode");
|
||||
}
|
||||
|
||||
#if ABL_PLANAR
|
||||
|
||||
bool do_topography_map = verbose_level > 2 || code_seen('T');
|
||||
do_topography_map = verbose_level > 2 || code_seen('T');
|
||||
|
||||
// X and Y specify points in each direction, overriding the default
|
||||
// These values may be saved with the completed mesh
|
||||
int abl_grid_points_x = code_seen('X') ? code_value_int() : ABL_GRID_MAX_POINTS_X,
|
||||
abl_grid_points_x = code_seen('X') ? code_value_int() : ABL_GRID_MAX_POINTS_X;
|
||||
abl_grid_points_y = code_seen('Y') ? code_value_int() : ABL_GRID_MAX_POINTS_Y;
|
||||
|
||||
if (code_seen('P')) abl_grid_points_x = abl_grid_points_y = code_value_int();
|
||||
|
||||
if (abl_grid_points_x < 2 || abl_grid_points_y < 2) {
|
||||
|
@ -4008,17 +4170,24 @@ inline void gcode_G28() {
|
|||
return;
|
||||
}
|
||||
|
||||
#else
|
||||
abl2 = abl_grid_points_x * abl_grid_points_y;
|
||||
|
||||
const uint8_t abl_grid_points_x = ABL_GRID_MAX_POINTS_X, abl_grid_points_y = ABL_GRID_MAX_POINTS_Y;
|
||||
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
||||
|
||||
zoffset = code_seen('Z') ? code_value_axis_units(Z_AXIS) : 0;
|
||||
#if HAS_BED_PROBE
|
||||
zoffset += zprobe_zoffset;
|
||||
#endif
|
||||
|
||||
#endif
|
||||
|
||||
#if ABL_GRID
|
||||
|
||||
xy_probe_feedrate_mm_s = MMM_TO_MMS(code_seen('S') ? code_value_linear_units() : XY_PROBE_SPEED);
|
||||
|
||||
int left_probe_bed_position = code_seen('L') ? (int)code_value_axis_units(X_AXIS) : LOGICAL_X_POSITION(LEFT_PROBE_BED_POSITION),
|
||||
right_probe_bed_position = code_seen('R') ? (int)code_value_axis_units(X_AXIS) : LOGICAL_X_POSITION(RIGHT_PROBE_BED_POSITION),
|
||||
front_probe_bed_position = code_seen('F') ? (int)code_value_axis_units(Y_AXIS) : LOGICAL_Y_POSITION(FRONT_PROBE_BED_POSITION),
|
||||
left_probe_bed_position = code_seen('L') ? (int)code_value_axis_units(X_AXIS) : LOGICAL_X_POSITION(LEFT_PROBE_BED_POSITION);
|
||||
right_probe_bed_position = code_seen('R') ? (int)code_value_axis_units(X_AXIS) : LOGICAL_X_POSITION(RIGHT_PROBE_BED_POSITION);
|
||||
front_probe_bed_position = code_seen('F') ? (int)code_value_axis_units(Y_AXIS) : LOGICAL_Y_POSITION(FRONT_PROBE_BED_POSITION);
|
||||
back_probe_bed_position = code_seen('B') ? (int)code_value_axis_units(Y_AXIS) : LOGICAL_Y_POSITION(BACK_PROBE_BED_POSITION);
|
||||
|
||||
const bool left_out_l = left_probe_bed_position < LOGICAL_X_POSITION(MIN_PROBE_X),
|
||||
|
@ -4050,13 +4219,20 @@ inline void gcode_G28() {
|
|||
return;
|
||||
}
|
||||
|
||||
// probe at the points of a lattice grid
|
||||
xGridSpacing = (right_probe_bed_position - left_probe_bed_position) / (abl_grid_points_x - 1);
|
||||
yGridSpacing = (back_probe_bed_position - front_probe_bed_position) / (abl_grid_points_y - 1);
|
||||
|
||||
#endif // ABL_GRID
|
||||
|
||||
if (verbose_level > 0) {
|
||||
SERIAL_PROTOCOLLNPGM("G29 Auto Bed Leveling");
|
||||
if (dryrun) SERIAL_PROTOCOLLNPGM("Running in DRY-RUN mode");
|
||||
}
|
||||
|
||||
stepper.synchronize();
|
||||
|
||||
// Disable auto bed leveling during G29
|
||||
bool abl_should_enable = planner.abl_enabled;
|
||||
|
||||
planner.abl_enabled = false;
|
||||
|
||||
if (!dryrun) {
|
||||
|
@ -4070,29 +4246,22 @@ inline void gcode_G28() {
|
|||
|
||||
setup_for_endstop_or_probe_move();
|
||||
|
||||
//xProbe = yProbe = measured_z = 0;
|
||||
|
||||
#if HAS_BED_PROBE
|
||||
// Deploy the probe. Probe will raise if needed.
|
||||
if (DEPLOY_PROBE()) {
|
||||
planner.abl_enabled = abl_should_enable;
|
||||
return;
|
||||
}
|
||||
|
||||
float xProbe = 0, yProbe = 0, measured_z = 0;
|
||||
|
||||
#if ABL_GRID
|
||||
|
||||
// probe at the points of a lattice grid
|
||||
const float xGridSpacing = (right_probe_bed_position - left_probe_bed_position) / (abl_grid_points_x - 1),
|
||||
yGridSpacing = (back_probe_bed_position - front_probe_bed_position) / (abl_grid_points_y - 1);
|
||||
#endif
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
||||
|
||||
float zoffset = zprobe_zoffset;
|
||||
if (code_seen('Z')) zoffset += code_value_axis_units(Z_AXIS);
|
||||
|
||||
if ( xGridSpacing != bilinear_grid_spacing[X_AXIS]
|
||||
|| yGridSpacing != bilinear_grid_spacing[Y_AXIS]
|
||||
|| left_probe_bed_position != bilinear_start[X_AXIS]
|
||||
|| front_probe_bed_position != bilinear_start[Y_AXIS]
|
||||
|| left_probe_bed_position != LOGICAL_X_POSITION(bilinear_start[X_AXIS])
|
||||
|| front_probe_bed_position != LOGICAL_Y_POSITION(bilinear_start[Y_AXIS])
|
||||
) {
|
||||
if (dryrun) {
|
||||
// Before reset bed level, re-enable to correct the position
|
||||
|
@ -4101,67 +4270,218 @@ inline void gcode_G28() {
|
|||
// Reset grid to 0.0 or "not probed". (Also disables ABL)
|
||||
reset_bed_level();
|
||||
|
||||
#if ENABLED(ABL_BILINEAR_SUBDIVISION)
|
||||
bilinear_grid_spacing_virt[X_AXIS] = xGridSpacing / (BILINEAR_SUBDIVISIONS);
|
||||
bilinear_grid_spacing_virt[Y_AXIS] = yGridSpacing / (BILINEAR_SUBDIVISIONS);
|
||||
#endif
|
||||
// Initialize a grid with the given dimensions
|
||||
bilinear_grid_spacing[X_AXIS] = xGridSpacing;
|
||||
bilinear_grid_spacing[Y_AXIS] = yGridSpacing;
|
||||
bilinear_start[X_AXIS] = RAW_X_POSITION(left_probe_bed_position);
|
||||
bilinear_start[Y_AXIS] = RAW_Y_POSITION(front_probe_bed_position);
|
||||
|
||||
#if ENABLED(ABL_BILINEAR_SUBDIVISION)
|
||||
bilinear_grid_spacing_virt[X_AXIS] = xGridSpacing / (BILINEAR_SUBDIVISIONS);
|
||||
bilinear_grid_spacing_virt[Y_AXIS] = yGridSpacing / (BILINEAR_SUBDIVISIONS);
|
||||
#endif
|
||||
|
||||
// Can't re-enable (on error) until the new grid is written
|
||||
abl_should_enable = false;
|
||||
}
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
|
||||
/**
|
||||
* solve the plane equation ax + by + d = z
|
||||
* A is the matrix with rows [x y 1] for all the probed points
|
||||
* B is the vector of the Z positions
|
||||
* the normal vector to the plane is formed by the coefficients of the
|
||||
* plane equation in the standard form, which is Vx*x+Vy*y+Vz*z+d = 0
|
||||
* so Vx = -a Vy = -b Vz = 1 (we want the vector facing towards positive Z
|
||||
*/
|
||||
|
||||
const int abl2 = abl_grid_points_x * abl_grid_points_y;
|
||||
|
||||
int indexIntoAB[abl_grid_points_x][abl_grid_points_y],
|
||||
probe_index = -1;
|
||||
|
||||
float eqnAMatrix[abl2 * 3], // "A" matrix of the linear system of equations
|
||||
eqnBVector[abl2], // "B" vector of Z points
|
||||
mean = 0.0;
|
||||
|
||||
#endif // AUTO_BED_LEVELING_LINEAR
|
||||
|
||||
#if ENABLED(PROBE_Y_FIRST)
|
||||
#define PR_OUTER_VAR xCount
|
||||
#define PR_OUTER_NUM abl_grid_points_x
|
||||
#define PR_INNER_VAR yCount
|
||||
#define PR_INNER_NUM abl_grid_points_y
|
||||
#else
|
||||
#define PR_OUTER_VAR yCount
|
||||
#define PR_OUTER_NUM abl_grid_points_y
|
||||
#define PR_INNER_VAR xCount
|
||||
#define PR_INNER_NUM abl_grid_points_x
|
||||
#if ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("> 3-point Leveling");
|
||||
#endif
|
||||
|
||||
bool zig = PR_OUTER_NUM & 1; // Always end at RIGHT and BACK_PROBE_BED_POSITION
|
||||
// Probe at 3 arbitrary points
|
||||
points[0].z = points[1].z = points[2].z = 0;
|
||||
|
||||
#endif // AUTO_BED_LEVELING_3POINT
|
||||
|
||||
} // !g29_in_progress
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
|
||||
// Abort current G29 procedure, go back to ABLStart
|
||||
if (code_seen('A') && g29_in_progress) {
|
||||
SERIAL_PROTOCOLLNPGM("Manual G29 aborted");
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
soft_endstops_enabled = enable_soft_endstops;
|
||||
#endif
|
||||
planner.abl_enabled = abl_should_enable;
|
||||
g29_in_progress = false;
|
||||
}
|
||||
|
||||
// Query G29 status
|
||||
if (code_seen('Q')) {
|
||||
if (!g29_in_progress)
|
||||
SERIAL_PROTOCOLLNPGM("Manual G29 idle");
|
||||
else {
|
||||
SERIAL_PROTOCOLPAIR("Manual G29 point ", abl_probe_index + 1);
|
||||
SERIAL_PROTOCOLLNPAIR(" of ", abl2);
|
||||
}
|
||||
}
|
||||
|
||||
if (code_seen('A') || code_seen('Q')) return;
|
||||
|
||||
// Fall through to probe the first point
|
||||
g29_in_progress = true;
|
||||
|
||||
if (abl_probe_index == 0) {
|
||||
// For the initial G29 S2 save software endstop state
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
enable_soft_endstops = soft_endstops_enabled;
|
||||
#endif
|
||||
}
|
||||
else {
|
||||
// For G29 after adjusting Z.
|
||||
// Save the previous Z before going to the next point
|
||||
measured_z = current_position[Z_AXIS];
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
|
||||
mean += measured_z;
|
||||
eqnBVector[abl_probe_index] = measured_z;
|
||||
eqnAMatrix[abl_probe_index + 0 * abl2] = xProbe;
|
||||
eqnAMatrix[abl_probe_index + 1 * abl2] = yProbe;
|
||||
eqnAMatrix[abl_probe_index + 2 * abl2] = 1;
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
||||
|
||||
bed_level_grid[xCount][yCount] = measured_z + zoffset;
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
points[i].z = measured_z;
|
||||
|
||||
#endif
|
||||
}
|
||||
|
||||
//
|
||||
// If there's another point to sample, move there with optional lift.
|
||||
//
|
||||
|
||||
#if ABL_GRID
|
||||
|
||||
// Find a next point to probe
|
||||
// On the first G29 this will be the first probe point
|
||||
while (abl_probe_index < abl2) {
|
||||
|
||||
// Set xCount, yCount based on abl_probe_index, with zig-zag
|
||||
PR_OUTER_VAR = abl_probe_index / PR_INNER_END;
|
||||
PR_INNER_VAR = abl_probe_index - (PR_OUTER_VAR * PR_INNER_END);
|
||||
|
||||
bool zig = (PR_OUTER_VAR & 1) != ((PR_OUTER_END) & 1);
|
||||
|
||||
if (zig) PR_INNER_VAR = (PR_INNER_END - 1) - PR_INNER_VAR;
|
||||
|
||||
const float xBase = left_probe_bed_position + xGridSpacing * xCount,
|
||||
yBase = front_probe_bed_position + yGridSpacing * yCount;
|
||||
|
||||
xProbe = floor(xBase + (xBase < 0 ? 0 : 0.5));
|
||||
yProbe = floor(yBase + (yBase < 0 ? 0 : 0.5));
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
indexIntoAB[xCount][yCount] = abl_probe_index;
|
||||
#endif
|
||||
|
||||
float pos[XYZ] = { xProbe, yProbe, 0 };
|
||||
if (position_is_reachable(pos)) break;
|
||||
++abl_probe_index;
|
||||
}
|
||||
|
||||
// Is there a next point to move to?
|
||||
if (abl_probe_index < abl2) {
|
||||
_manual_goto_xy(xProbe, yProbe); // Can be used here too!
|
||||
++abl_probe_index;
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
// Disable software endstops to allow manual adjustment
|
||||
// If G29 is not completed, they will not be re-enabled
|
||||
soft_endstops_enabled = false;
|
||||
#endif
|
||||
return;
|
||||
}
|
||||
else {
|
||||
// Then leveling is done!
|
||||
// G29 finishing code goes here
|
||||
|
||||
// After recording the last point, activate abl
|
||||
SERIAL_PROTOCOLLNPGM("Grid probing done.");
|
||||
g29_in_progress = false;
|
||||
|
||||
// Re-enable software endstops, if needed
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
soft_endstops_enabled = enable_soft_endstops;
|
||||
#endif
|
||||
}
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
// Probe at 3 arbitrary points
|
||||
if (abl_probe_index < 3) {
|
||||
xProbe = LOGICAL_X_POSITION(points[i].x);
|
||||
yProbe = LOGICAL_Y_POSITION(points[i].y);
|
||||
++abl_probe_index;
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
// Disable software endstops to allow manual adjustment
|
||||
// If G29 is not completed, they will not be re-enabled
|
||||
soft_endstops_enabled = false;
|
||||
#endif
|
||||
return;
|
||||
}
|
||||
else {
|
||||
|
||||
SERIAL_PROTOCOLLNPGM("3-point probing done.");
|
||||
g29_in_progress = false;
|
||||
|
||||
// Re-enable software endstops, if needed
|
||||
#if HAS_SOFTWARE_ENDSTOPS
|
||||
soft_endstops_enabled = enable_soft_endstops;
|
||||
#endif
|
||||
|
||||
if (!dryrun) {
|
||||
vector_3 planeNormal = vector_3::cross(points[0] - points[1], points[2] - points[1]).get_normal();
|
||||
if (planeNormal.z < 0) {
|
||||
planeNormal.x *= -1;
|
||||
planeNormal.y *= -1;
|
||||
planeNormal.z *= -1;
|
||||
}
|
||||
planner.bed_level_matrix = matrix_3x3::create_look_at(planeNormal);
|
||||
|
||||
// Can't re-enable (on error) until the new grid is written
|
||||
abl_should_enable = false;
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
#endif // AUTO_BED_LEVELING_3POINT
|
||||
|
||||
|
||||
#else // !PROBE_MANUALLY
|
||||
|
||||
|
||||
bool stow_probe_after_each = code_seen('E');
|
||||
|
||||
#if ABL_GRID
|
||||
|
||||
bool zig = PR_OUTER_END & 1; // Always end at RIGHT and BACK_PROBE_BED_POSITION
|
||||
|
||||
// Outer loop is Y with PROBE_Y_FIRST disabled
|
||||
for (uint8_t PR_OUTER_VAR = 0; PR_OUTER_VAR < PR_OUTER_NUM; PR_OUTER_VAR++) {
|
||||
for (uint8_t PR_OUTER_VAR = 0; PR_OUTER_VAR < PR_OUTER_END; PR_OUTER_VAR++) {
|
||||
|
||||
int8_t inStart, inStop, inInc;
|
||||
|
||||
if (zig) { // away from origin
|
||||
inStart = 0;
|
||||
inStop = PR_INNER_NUM;
|
||||
inStop = PR_INNER_END;
|
||||
inInc = 1;
|
||||
}
|
||||
else { // towards origin
|
||||
inStart = PR_INNER_NUM - 1;
|
||||
inStart = PR_INNER_END - 1;
|
||||
inStop = -1;
|
||||
inInc = -1;
|
||||
}
|
||||
|
@ -4178,7 +4498,7 @@ inline void gcode_G28() {
|
|||
yProbe = floor(yBase + (yBase < 0 ? 0 : 0.5));
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
indexIntoAB[xCount][yCount] = ++probe_index;
|
||||
indexIntoAB[xCount][yCount] = ++abl_probe_index;
|
||||
#endif
|
||||
|
||||
#if IS_KINEMATIC
|
||||
|
@ -4197,10 +4517,10 @@ inline void gcode_G28() {
|
|||
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
|
||||
|
||||
mean += measured_z;
|
||||
eqnBVector[probe_index] = measured_z;
|
||||
eqnAMatrix[probe_index + 0 * abl2] = xProbe;
|
||||
eqnAMatrix[probe_index + 1 * abl2] = yProbe;
|
||||
eqnAMatrix[probe_index + 2 * abl2] = 1;
|
||||
eqnBVector[abl_probe_index] = measured_z;
|
||||
eqnAMatrix[abl_probe_index + 0 * abl2] = xProbe;
|
||||
eqnAMatrix[abl_probe_index + 1 * abl2] = yProbe;
|
||||
eqnAMatrix[abl_probe_index + 2 * abl2] = 1;
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
||||
|
||||
|
@ -4208,6 +4528,7 @@ inline void gcode_G28() {
|
|||
|
||||
#endif
|
||||
|
||||
abl_should_enable = false;
|
||||
idle();
|
||||
|
||||
} // inner
|
||||
|
@ -4215,16 +4536,7 @@ inline void gcode_G28() {
|
|||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("> 3-point Leveling");
|
||||
#endif
|
||||
|
||||
// Probe at 3 arbitrary points
|
||||
vector_3 points[3] = {
|
||||
vector_3(ABL_PROBE_PT_1_X, ABL_PROBE_PT_1_Y, 0),
|
||||
vector_3(ABL_PROBE_PT_2_X, ABL_PROBE_PT_2_Y, 0),
|
||||
vector_3(ABL_PROBE_PT_3_X, ABL_PROBE_PT_3_Y, 0)
|
||||
};
|
||||
|
||||
for (uint8_t i = 0; i < 3; ++i) {
|
||||
// Retain the last probe position
|
||||
|
@ -4259,6 +4571,10 @@ inline void gcode_G28() {
|
|||
return;
|
||||
}
|
||||
|
||||
#endif // !PROBE_MANUALLY
|
||||
|
||||
//
|
||||
// G29 Finishing Code
|
||||
//
|
||||
// Unless this is a dry run, auto bed leveling will
|
||||
// definitely be enabled after this point
|
||||
|
@ -4286,7 +4602,14 @@ inline void gcode_G28() {
|
|||
|
||||
// For LINEAR leveling calculate matrix, print reports, correct the position
|
||||
|
||||
// solve lsq problem
|
||||
/**
|
||||
* solve the plane equation ax + by + d = z
|
||||
* A is the matrix with rows [x y 1] for all the probed points
|
||||
* B is the vector of the Z positions
|
||||
* the normal vector to the plane is formed by the coefficients of the
|
||||
* plane equation in the standard form, which is Vx*x+Vy*y+Vz*z+d = 0
|
||||
* so Vx = -a Vy = -b Vz = 1 (we want the vector facing towards positive Z
|
||||
*/
|
||||
float plane_equation_coefficients[3];
|
||||
qr_solve(plane_equation_coefficients, abl2, 3, eqnAMatrix, eqnBVector);
|
||||
|
||||
|
|
|
@ -130,8 +130,12 @@
|
|||
#error "Z_RAISE_PROBE_DEPLOY_STOW and Z_RAISE_BETWEEN_PROBINGS are now Z_CLEARANCE_DEPLOY_PROBE and Z_CLEARANCE_BETWEEN_PROBES. Please update your configuration."
|
||||
#elif defined(Z_PROBE_DEPLOY_HEIGHT) || defined(Z_PROBE_TRAVEL_HEIGHT)
|
||||
#error "Z_PROBE_DEPLOY_HEIGHT and Z_PROBE_TRAVEL_HEIGHT are now Z_CLEARANCE_DEPLOY_PROBE and Z_CLEARANCE_BETWEEN_PROBES. Please update your configuration."
|
||||
#elif defined(MANUAL_BED_LEVELING)
|
||||
#error "MANUAL_BED_LEVELING is now LCD_BED_LEVELING. Please update your configuration."
|
||||
#elif defined(MESH_HOME_SEARCH_Z)
|
||||
#error "MESH_HOME_SEARCH_Z is now MANUAL_PROBE_Z_RANGE. Please update your configuration."
|
||||
#error "MESH_HOME_SEARCH_Z is now LCD_PROBE_Z_RANGE. Please update your configuration."
|
||||
#elif defined(MANUAL_PROBE_Z_RANGE)
|
||||
#error "MANUAL_PROBE_Z_RANGE is now LCD_PROBE_Z_RANGE. Please update your configuration."
|
||||
#elif !defined(MIN_STEPS_PER_SEGMENT)
|
||||
#error Please replace "const int dropsegments" with "#define MIN_STEPS_PER_SEGMENT" (and increase by 1) in Configuration_adv.h.
|
||||
#elif defined(PREVENT_DANGEROUS_EXTRUDE)
|
||||
|
@ -408,8 +412,6 @@ static_assert(1 >= 0
|
|||
#elif MESH_NUM_X_POINTS > 9 || MESH_NUM_Y_POINTS > 9
|
||||
#error "MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS must be less than 10."
|
||||
#endif
|
||||
#elif ENABLED(MANUAL_BED_LEVELING)
|
||||
#error "MANUAL_BED_LEVELING only applies to MESH_BED_LEVELING."
|
||||
#endif
|
||||
|
||||
/**
|
||||
|
@ -492,7 +494,7 @@ static_assert(1 >= 0
|
|||
#if !HAS_Z_MIN_PROBE_PIN
|
||||
#error "Z_MIN_PROBE_ENDSTOP requires the Z_MIN_PROBE_PIN to be defined."
|
||||
#endif
|
||||
#else
|
||||
#elif DISABLED(PROBE_MANUALLY)
|
||||
#error "You must enable either Z_MIN_PROBE_ENDSTOP or Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to use a probe."
|
||||
#endif
|
||||
|
||||
|
@ -523,10 +525,10 @@ static_assert(1 >= 0
|
|||
#endif
|
||||
|
||||
/**
|
||||
* MANUAL_BED_LEVELING requirements
|
||||
* LCD_BED_LEVELING requirements
|
||||
*/
|
||||
#if ENABLED(MANUAL_BED_LEVELING) && DISABLED(MESH_BED_LEVELING)
|
||||
#error "MANUAL_BED_LEVELING requires MESH_BED_LEVELING."
|
||||
#if ENABLED(LCD_BED_LEVELING) && DISABLED(MESH_BED_LEVELING) && !(HAS_ABL && ENABLED(PROBE_MANUALLY))
|
||||
#error "LCD_BED_LEVELING requires MESH_BED_LEVELING or PROBE_MANUALLY."
|
||||
#endif
|
||||
|
||||
/**
|
||||
|
|
|
@ -165,16 +165,6 @@ enum TempState {
|
|||
};
|
||||
#endif
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
enum ABLState {
|
||||
ABLReport,
|
||||
ABLStart,
|
||||
ABLNext,
|
||||
ABLSet,
|
||||
ABLReset
|
||||
};
|
||||
#endif
|
||||
|
||||
/**
|
||||
* SD Card
|
||||
*/
|
||||
|
|
|
@ -232,7 +232,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -545,6 +545,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -741,7 +746,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -877,15 +881,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1433,13 +1441,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -528,6 +528,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -724,7 +729,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -860,15 +864,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1416,13 +1424,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -528,6 +528,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -724,7 +729,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -860,15 +864,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1416,13 +1424,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -234,7 +234,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -537,6 +537,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -733,7 +738,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -869,15 +873,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1425,13 +1433,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -539,6 +539,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -735,7 +740,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -871,15 +875,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1427,13 +1435,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -251,7 +251,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -574,6 +574,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -770,7 +775,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -906,15 +910,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1467,13 +1475,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -545,6 +545,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -741,7 +746,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -877,15 +881,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1433,13 +1441,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -545,6 +545,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -741,7 +746,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -877,15 +881,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1433,13 +1441,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -545,6 +545,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -741,7 +746,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -877,15 +881,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1433,13 +1441,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -234,7 +234,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -544,6 +544,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -740,7 +745,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -876,15 +880,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1434,13 +1442,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -263,7 +263,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -560,6 +560,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -756,7 +761,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -892,15 +896,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1448,13 +1456,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -566,6 +566,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -762,7 +767,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -898,15 +902,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1454,13 +1462,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -234,7 +234,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -537,6 +537,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -733,7 +738,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -869,15 +873,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1425,13 +1433,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -545,6 +545,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -741,7 +746,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -877,15 +881,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1433,13 +1441,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -603,6 +603,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -982,15 +987,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1538,13 +1547,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -590,6 +590,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -831,7 +836,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -968,15 +972,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1523,13 +1531,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -590,6 +590,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -834,7 +839,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -972,15 +976,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1527,13 +1535,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -235,7 +235,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -584,6 +584,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -833,7 +838,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -971,15 +975,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1526,13 +1534,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -603,6 +603,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -844,7 +849,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -981,15 +985,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1536,13 +1544,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -548,6 +548,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -744,7 +749,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -880,15 +884,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1436,13 +1444,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -231,7 +231,7 @@
|
|||
* 60 : 100k Maker's Tool Works Kapton Bed Thermistor beta=3950
|
||||
* 66 : 4.7M High Temperature thermistor from Dyze Design
|
||||
* 70 : the 100K thermistor found in the bq Hephestos 2
|
||||
* 75 : 100k Generic Silicon Heat Pad typically a NTC 100K MGB18-104F39050L32 thermistor
|
||||
* 75 : 100k Generic Silicon Heat Pad with NTC 100K MGB18-104F39050L32 thermistor
|
||||
*
|
||||
* 1k ohm pullup tables - This is atypical, and requires changing out the 4.7k pullup for 1k.
|
||||
* (but gives greater accuracy and more stable PID)
|
||||
|
@ -541,6 +541,11 @@
|
|||
// Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
|
||||
//
|
||||
|
||||
// The "Manual Probe" provides a means to do "Auto" Bed Leveling without a probe.
|
||||
// Use G29 repeatedly, adjusting the Z height at each point with movement commands
|
||||
// or (with LCD_BED_LEVELING) the LCD controller.
|
||||
//#define PROBE_MANUALLY
|
||||
|
||||
// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
|
||||
// For example an inductive probe, or a setup that uses the nozzle to probe.
|
||||
// An inductive probe must be deactivated to go below
|
||||
|
@ -737,7 +742,6 @@
|
|||
#define FILAMENT_RUNOUT_SCRIPT "M600"
|
||||
#endif
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//=============================== Bed Leveling ==============================
|
||||
//===========================================================================
|
||||
|
@ -873,15 +877,19 @@
|
|||
|
||||
//#define MESH_G28_REST_ORIGIN // After homing all axes ('G28' or 'G28 XYZ') rest Z at Z_MIN_POS
|
||||
|
||||
//#define MANUAL_BED_LEVELING // Add display menu option for bed leveling.
|
||||
#define MANUAL_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#endif
|
||||
|
||||
#endif // BED_LEVELING
|
||||
|
||||
/**
|
||||
* Use the LCD controller for bed leveling
|
||||
* Requires MESH_BED_LEVELING or PROBE_MANUALLY
|
||||
*/
|
||||
//#define LCD_BED_LEVELING
|
||||
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
#define MBL_Z_STEP 0.025 // Step size while manually probing Z axis.
|
||||
#define LCD_PROBE_Z_RANGE 4 // Z Range centered on Z_MIN_POS for LCD Z adjustment
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Commands to execute at the end of G29 probing.
|
||||
* Useful to retract or move the Z probe out of the way.
|
||||
|
@ -1429,13 +1437,13 @@
|
|||
|
||||
// If SOFT_PWM_SCALE is set to a value higher than 0, dithering can
|
||||
// be used to mitigate the associated resolution loss. If enabled,
|
||||
// some of the PWM cycles are stretched so on average the wanted
|
||||
// some of the PWM cycles are stretched so on average the desired
|
||||
// duty cycle is attained.
|
||||
//#define SOFT_PWM_DITHER
|
||||
|
||||
// Temperature status LEDs that display the hotend and bed temperature.
|
||||
// If all hotends and bed temperature and temperature setpoint are < 54C then the BLUE led is on.
|
||||
// Otherwise the RED led is on. There is 1C hysteresis.
|
||||
// If all hotends, bed temperature, and target temperature are under 54C
|
||||
// then the BLUE led is on. Otherwise the RED led is on. (1C hysteresis)
|
||||
//#define TEMP_STAT_LEDS
|
||||
|
||||
// M240 Triggers a camera by emulating a Canon RC-1 Remote
|
||||
|
|
|
@ -181,7 +181,7 @@ uint16_t max_display_update_time = 0;
|
|||
void lcd_delta_calibrate_menu();
|
||||
#endif
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#if ENABLED(MESH_BED_LEVELING) && ENABLED(LCD_BED_LEVELING)
|
||||
#include "mesh_bed_leveling.h"
|
||||
#endif
|
||||
|
||||
|
@ -457,13 +457,18 @@ uint16_t max_display_update_time = 0;
|
|||
* Synchronize safely while holding the current screen
|
||||
* This blocks all further screen or stripe updates once called
|
||||
*/
|
||||
extern uint8_t commands_in_queue;
|
||||
|
||||
inline void lcd_synchronize() {
|
||||
lcd_implementation_drawmenu_static(LCD_HEIGHT >= 4 ? 1 : 0, PSTR(MSG_MOVING));
|
||||
if (no_reentrance) return;
|
||||
no_reentrance = true;
|
||||
screenFunc_t old_screen = currentScreen;
|
||||
lcd_goto_screen(lcd_synchronize);
|
||||
while (commands_in_queue) {
|
||||
idle();
|
||||
stepper.synchronize();
|
||||
}
|
||||
no_reentrance = false;
|
||||
lcd_goto_screen(old_screen);
|
||||
}
|
||||
|
@ -982,7 +987,7 @@ void kill_screen(const char* lcd_msg) {
|
|||
MENU_ITEM_EDIT(int3, MSG_SPEED, &feedrate_percentage, 10, 999);
|
||||
|
||||
// Manual bed leveling, Bed Z:
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#if ENABLED(MESH_BED_LEVELING) && ENABLED(LCD_BED_LEVELING)
|
||||
MENU_ITEM_EDIT(float43, MSG_BED_Z, &mbl.z_offset, -1, 1);
|
||||
#endif
|
||||
|
||||
|
@ -1321,18 +1326,37 @@ void kill_screen(const char* lcd_msg) {
|
|||
|
||||
#endif
|
||||
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
|
||||
/**
|
||||
*
|
||||
* "Prepare" > "Bed Leveling" handlers
|
||||
* "Prepare" > "Level Bed" handlers
|
||||
*
|
||||
*/
|
||||
|
||||
static uint8_t manual_probe_index;
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
extern bool g29_in_progress;
|
||||
#endif
|
||||
|
||||
// LCD probed points are from defaults
|
||||
constexpr uint8_t total_probe_points =
|
||||
#if ABL_GRID
|
||||
(ABL_GRID_MAX_POINTS_X) * (ABL_GRID_MAX_POINTS_Y)
|
||||
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
|
||||
int(3)
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
(UBL_MESH_NUM_X_POINTS) * (UBL_MESH_NUM_Y_POINTS)
|
||||
#elif ENABLED(MESH_BED_LEVELING)
|
||||
(MESH_NUM_X_POINTS) * (MESH_NUM_Y_POINTS)
|
||||
#endif
|
||||
;
|
||||
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
|
||||
// Utility to go to the next mesh point
|
||||
inline void _manual_probe_xy(float x, float y) {
|
||||
inline void _manual_probe_goto_xy(float x, float y) {
|
||||
if (no_reentrance) return;
|
||||
#if MANUAL_PROBE_HEIGHT > 0
|
||||
current_position[Z_AXIS] = LOGICAL_Z_POSITION(Z_MIN_POS) + MANUAL_PROBE_HEIGHT;
|
||||
|
@ -1348,7 +1372,11 @@ void kill_screen(const char* lcd_msg) {
|
|||
lcd_synchronize();
|
||||
}
|
||||
|
||||
#endif // MESH_BED_LEVELING
|
||||
|
||||
#if ENABLED(MESH_BED_LEVELING) || ENABLED(PROBE_MANUALLY)
|
||||
void _lcd_level_goto_next_point();
|
||||
#endif
|
||||
|
||||
void _lcd_level_bed_done() {
|
||||
if (lcdDrawUpdate) lcd_implementation_drawedit(PSTR(MSG_LEVEL_BED_DONE));
|
||||
|
@ -1356,7 +1384,19 @@ void kill_screen(const char* lcd_msg) {
|
|||
}
|
||||
|
||||
/**
|
||||
* Step 7: Get the Z coordinate, then goto next point or exit
|
||||
* Step 6: Display "Next point: 1 / 9" while waiting for move to finish
|
||||
*/
|
||||
void _lcd_level_bed_moving() {
|
||||
if (lcdDrawUpdate) {
|
||||
char msg[10];
|
||||
sprintf_P(msg, PSTR("%i / %u"), (int)(manual_probe_index + 1), total_probe_points);
|
||||
lcd_implementation_drawedit(PSTR(MSG_LEVEL_BED_NEXT_POINT), msg);
|
||||
}
|
||||
lcdDrawUpdate = LCDVIEW_KEEP_REDRAWING;
|
||||
}
|
||||
|
||||
/**
|
||||
* Step 7: Get the Z coordinate, click goes to the next point or exits
|
||||
*/
|
||||
void _lcd_level_bed_get_z() {
|
||||
ENCODER_DIRECTION_NORMAL();
|
||||
|
@ -1367,79 +1407,131 @@ void kill_screen(const char* lcd_msg) {
|
|||
if (encoderPosition) {
|
||||
refresh_cmd_timeout();
|
||||
current_position[Z_AXIS] += float((int32_t)encoderPosition) * (MBL_Z_STEP);
|
||||
NOLESS(current_position[Z_AXIS], -(MANUAL_PROBE_Z_RANGE) * 0.5);
|
||||
NOMORE(current_position[Z_AXIS], (MANUAL_PROBE_Z_RANGE) * 0.5);
|
||||
NOLESS(current_position[Z_AXIS], -(LCD_PROBE_Z_RANGE) * 0.5);
|
||||
NOMORE(current_position[Z_AXIS], (LCD_PROBE_Z_RANGE) * 0.5);
|
||||
line_to_current(Z_AXIS);
|
||||
lcdDrawUpdate = LCDVIEW_KEEP_REDRAWING;
|
||||
encoderPosition = 0;
|
||||
}
|
||||
|
||||
if (lcd_clicked) {
|
||||
|
||||
// Use a hook to set the probe point z
|
||||
// (zigzag arranges in XY order)
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
// UBL set-z handling goes here
|
||||
|
||||
#elif ENABLED(PROBE_MANUALLY)
|
||||
|
||||
// G29 helpfully records Z and goes to the next
|
||||
// point (or beeps if done)
|
||||
enqueue_and_echo_commands_P(PSTR("G29"));
|
||||
manual_probe_index++;
|
||||
|
||||
#elif ENABLED(MESH_BED_LEVELING)
|
||||
|
||||
mbl.set_zigzag_z(manual_probe_index++, current_position[Z_AXIS]);
|
||||
if (manual_probe_index == (MESH_NUM_X_POINTS) * (MESH_NUM_Y_POINTS)) {
|
||||
|
||||
#endif
|
||||
|
||||
// If done...
|
||||
if (manual_probe_index == total_probe_points) {
|
||||
|
||||
// Say "Done!"
|
||||
lcd_goto_screen(_lcd_level_bed_done);
|
||||
|
||||
// Raise Z to the "manual probe height"
|
||||
#if MANUAL_PROBE_HEIGHT > 0
|
||||
current_position[Z_AXIS] = LOGICAL_Z_POSITION(Z_MIN_POS) + MANUAL_PROBE_HEIGHT;
|
||||
line_to_current(Z_AXIS);
|
||||
lcd_synchronize();
|
||||
#endif
|
||||
|
||||
// Enable leveling, if needed
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
|
||||
mbl.set_has_mesh(true);
|
||||
mbl.set_reactivate(true);
|
||||
enqueue_and_echo_commands_P(PSTR("G28"));
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
// UBL enable goes here
|
||||
|
||||
#elif ENABLED(PROBE_MANUALLY)
|
||||
|
||||
// ABL will be enabled due to "G29".
|
||||
|
||||
#endif
|
||||
|
||||
lcd_return_to_status();
|
||||
//LCD_MESSAGEPGM(MSG_LEVEL_BED_DONE);
|
||||
lcd_completion_feedback();
|
||||
}
|
||||
else {
|
||||
lcd_goto_screen(_lcd_level_goto_next_point);
|
||||
|
||||
// Move to the next probe point, if needed
|
||||
#if ENABLED(MESH_BED_LEVELING) || ENABLED(PROBE_MANUALLY)
|
||||
|
||||
_lcd_level_goto_next_point();
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
// UBL goto-next-point goes here
|
||||
|
||||
#endif
|
||||
}
|
||||
}
|
||||
|
||||
KeepDrawing:
|
||||
KeepDrawing:
|
||||
|
||||
// Update on first display, then only on updates to Z position
|
||||
// Show message above on clicks instead
|
||||
if (lcdDrawUpdate) {
|
||||
const float v = current_position[Z_AXIS];
|
||||
lcd_implementation_drawedit(PSTR(MSG_MOVE_Z), ftostr43sign(v + (v < 0 ? -0.0001 : 0.0001), '+'));
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
/**
|
||||
* Step 6: Display "Next point: 1 / 9" while waiting for move to finish
|
||||
*/
|
||||
void _lcd_level_bed_moving() {
|
||||
if (lcdDrawUpdate) {
|
||||
char msg[10];
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
sprintf_P(msg, PSTR("%i / %u"), (int)(manual_probe_index + 1), (MESH_NUM_X_POINTS) * (MESH_NUM_Y_POINTS));
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
sprintf_P(msg, PSTR("%i / %u"), (int)(manual_probe_index + 1), (UBL_MESH_NUM_X_POINTS) * (UBL_MESH_NUM_Y_POINTS));
|
||||
#endif
|
||||
lcd_implementation_drawedit(PSTR(MSG_LEVEL_BED_NEXT_POINT), msg);
|
||||
}
|
||||
|
||||
lcdDrawUpdate = LCDVIEW_KEEP_REDRAWING;
|
||||
}
|
||||
#if ENABLED(MESH_BED_LEVELING) || ENABLED(PROBE_MANUALLY)
|
||||
|
||||
/**
|
||||
* Step 5: Initiate a move to the next point
|
||||
*/
|
||||
void _lcd_level_goto_next_point() {
|
||||
|
||||
// Set the menu to display ahead of blocking call
|
||||
lcd_goto_screen(_lcd_level_bed_moving);
|
||||
|
||||
// _manual_probe_xy runs the menu loop until the move is done
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
|
||||
int8_t px, py;
|
||||
mbl.zigzag(manual_probe_index, px, py);
|
||||
_manual_probe_xy(mbl.index_to_xpos[px], mbl.index_to_ypos[py]);
|
||||
|
||||
// Controls the loop until the move is done
|
||||
_manual_probe_goto_xy(
|
||||
LOGICAL_X_POSITION(mbl.index_to_xpos[px]),
|
||||
LOGICAL_Y_POSITION(mbl.index_to_ypos[py])
|
||||
);
|
||||
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
// UBL may have its own methodology
|
||||
|
||||
#elif ENABLED(PROBE_MANUALLY)
|
||||
|
||||
// Just wait for the G29 move to complete
|
||||
lcd_synchronize();
|
||||
|
||||
#endif
|
||||
|
||||
// After the blocking function returns, change menus
|
||||
lcd_goto_screen(_lcd_level_bed_get_z);
|
||||
}
|
||||
|
||||
#endif // MESH_BED_LEVELING
|
||||
|
||||
/**
|
||||
* Step 4: Display "Click to Begin", wait for click
|
||||
* Move to the first probe position
|
||||
|
@ -1448,7 +1540,14 @@ KeepDrawing:
|
|||
if (lcdDrawUpdate) lcd_implementation_drawedit(PSTR(MSG_LEVEL_BED_WAITING));
|
||||
if (lcd_clicked) {
|
||||
manual_probe_index = 0;
|
||||
lcd_goto_screen(_lcd_level_goto_next_point);
|
||||
#if ENABLED(MESH_BED_LEVELING)
|
||||
_lcd_level_goto_next_point();
|
||||
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
// UBL click handling should go here
|
||||
#elif ENABLED(PROBE_MANUALLY)
|
||||
enqueue_and_echo_commands_P(PSTR("G29"));
|
||||
_lcd_level_goto_next_point();
|
||||
#endif
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -1466,15 +1565,17 @@ KeepDrawing:
|
|||
* Step 2: Continue Bed Leveling...
|
||||
*/
|
||||
void _lcd_level_bed_continue() {
|
||||
#if PLANNER_LEVELING && DISABLED(AUTO_BED_LEVELING_UBL)
|
||||
reset_bed_level();
|
||||
#endif
|
||||
defer_return_to_status = true;
|
||||
axis_homed[X_AXIS] = axis_homed[Y_AXIS] = axis_homed[Z_AXIS] = false;
|
||||
mbl.reset();
|
||||
enqueue_and_echo_commands_P(PSTR("G28"));
|
||||
lcd_goto_screen(_lcd_level_bed_homing);
|
||||
enqueue_and_echo_commands_P(PSTR("G28"));
|
||||
}
|
||||
|
||||
/**
|
||||
* Step 1: MBL entry-point: "Cancel" or "Level Bed"
|
||||
* Step 1: Bed Level entry-point: "Cancel" or "Level Bed"
|
||||
*/
|
||||
void lcd_level_bed() {
|
||||
START_MENU();
|
||||
|
@ -1483,7 +1584,7 @@ KeepDrawing:
|
|||
END_MENU();
|
||||
}
|
||||
|
||||
#endif // MANUAL_BED_LEVELING
|
||||
#endif // LCD_BED_LEVELING
|
||||
|
||||
/**
|
||||
*
|
||||
|
@ -1520,12 +1621,19 @@ KeepDrawing:
|
|||
//
|
||||
// Level Bed
|
||||
//
|
||||
#if HAS_ABL
|
||||
#if ENABLED(LCD_BED_LEVELING)
|
||||
|
||||
#if ENABLED(PROBE_MANUALLY)
|
||||
if (!g29_in_progress)
|
||||
#endif
|
||||
MENU_ITEM(submenu, MSG_LEVEL_BED, lcd_level_bed);
|
||||
|
||||
#elif HAS_ABL
|
||||
|
||||
MENU_ITEM(gcode, MSG_LEVEL_BED,
|
||||
axis_homed[X_AXIS] && axis_homed[Y_AXIS] ? PSTR("G29") : PSTR("G28\nG29")
|
||||
);
|
||||
#elif ENABLED(MANUAL_BED_LEVELING)
|
||||
MENU_ITEM(submenu, MSG_LEVEL_BED, lcd_level_bed);
|
||||
|
||||
#endif
|
||||
|
||||
#if DISABLED(NO_WORKSPACE_OFFSETS)
|
||||
|
@ -2253,7 +2361,7 @@ KeepDrawing:
|
|||
MENU_ITEM_EDIT(float32, MSG_ZPROBE_ZOFFSET, &zprobe_zoffset, Z_PROBE_OFFSET_RANGE_MIN, Z_PROBE_OFFSET_RANGE_MAX);
|
||||
#endif
|
||||
// Manual bed leveling, Bed Z:
|
||||
#if ENABLED(MANUAL_BED_LEVELING)
|
||||
#if ENABLED(MESH_BED_LEVELING) && ENABLED(LCD_BED_LEVELING)
|
||||
MENU_ITEM_EDIT(float43, MSG_BED_Z, &mbl.z_offset, -1, 1);
|
||||
#endif
|
||||
MENU_ITEM_EDIT(float5, MSG_ACC, &planner.acceleration, 10, 99000);
|
||||
|
|
Loading…
Reference in a new issue