Author SHA1 Message Date
Scott Lahteine 46360f18b4 Bring thermistor_75.h up to speed 2018-10-23 14:52:16 -05:00
HenningJW 4fb2134f00 Fix non-sensical values for Zonestar themistor table (#11817)
Values taken from Zonestar firmware for P802QA with a Melzi board. Timestamps from the firmware package are from April 2016.
2018-09-12 15:36:04 -05:00
Scott Lahteine f1347f783d Optimize thermistor table 71
agData in Table 71 is extremely oversampled (see Issue #11220). I have removed the data points that perform *worse* than linearly interpolating the remaining points, and fixed up two points that were simply rounded incorrectly.

Co-Authored-By: Aaron Griffith <aargri@gmail.com>
2018-08-13 02:54:55 -05:00
Lee Olivares 094e6d81a5 Add Einstart-S support (#11219)
Indeed the HAL does not need to be mucked around with to expose ATmega2560 pins not available as numbers on the MEGA board, I'll need to update the wiki with that tidbit and a reference to the pin-mapping comment in `fastio_1280.h`.
2018-07-26 05:52:22 -05:00
Scott Lahteine 6b521b6df2 Loosen thermistor table size limit
Co-Authored-By: Aaron Griffith <aargri@gmail.com>
2018-07-11 21:08:07 -05:00
Scott Lahteine 568cfe7caa Add thermistor 501 (100K Zonestar) 2018-07-03 17:52:06 -05:00
Scott Lahteine 334341c632
Hephestos config updates (#10960) 2018-06-07 21:23:55 -05:00
Scott Lahteine 853a9056ac Long thermistor tables need special consideration 2018-05-28 06:28:34 -05:00
Scott Lahteine a4f9c3373f Tweak thermistor spacing 2018-05-28 03:44:32 -05:00
Scott Lahteine 325bbbc8c2
[2.0.x] Enable AD595 and AD8495 in concert (#10693)
* Allow both AD595 and AD8495 in concert
* General temperature code tweaks
2018-05-11 01:01:51 -05:00
Lenbok 0e8242180d Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback, updated for 2.0.x.

Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?

Chamber temperatures are not reported on the LCD in any way.

When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.

As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
2018-04-06 23:09:06 -05:00
ABH10 ac6bf7226a Update of comments in thermistor files. No functional changes. (#8986) 2018-02-04 06:06:21 -06:00
Scott Lahteine 7d6c009104 Add thermistor 15 tuned for JGAurora A5 2018-01-22 01:27:11 -06:00
GMagician 5295b4713d [2.0.x] add semitec 104NT-4 (#9119)
Table is very very similar to old 104-GT2 so I added only the name and recycled old ID
2018-01-09 16:53:12 -06:00
Scott Lahteine 0918dae66e Add OV() macro for use in thermistor tables 2017-11-15 03:15:18 -06:00
Scott Lahteine 3d8a0ab4b2 Module updates 2017-09-21 16:26:42 -05:00
Scott Lahteine 2b3b7d5d7f Move 'thermistor' files 2017-09-12 14:51:05 -05:00