Some clean-up for example configuration files
Follow-up and fix the PR #3253(Make the Autotune item(s) in the LCD menu optional):
・Update forgotten file(Felix/Configuration_DUAL.h)
Follow-up the PR #3526(Configuration.h LCD & SDCard section rewrite):
・Add section of RigidBot Panel to RepRapWorld/Megatronics/Configuration.h
Follow-up the PR #3576(Z Safe Homing for all):
・Adjust spacing
Follow-up and fix the PR #3625(Print job statistics):
・Update forgotten file(Felix/Configuration_DUAL.h)
・Remove ambiguous character "f" in top of RigidBot/Configuration.h
When setting the bed temp via M140/M190 if the thermistor does not read an increase of WATCH_BED_TEMP_INCREASE degrees by WATCH_BED_TEMP_PERIOD seconds then it will throw "Error:Heating failed, system stopped! Heater_ID: bed" and call the kill() function.
Conflicts:
Marlin/Configuration_adv.h
Follow-up the PR #3082
Follow-up the commit 143ad74: unnoticed updates
Fix for commit b0f5ba0: Z offset: -front [of the nozzle] +behind -> Y offset: -front [of the nozzle] +behind
Standardize the writing method: Z-probe, z-probe -> Z Probe
Adjust spacing
Aim: Test probes in update_endstops only when activated
Changes:
Configurations
Add define for FIX_MOUNTED_PROBE to handle the situation where formerly ENDSTOPS_ONLY_FOR_HOMING had to be set, or lowering the nozzle below Z_PROBE_OFFSET_FROM_EXTRUDER could give an "endstop hit" message.
Add define for Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to indicate a common situation, that we have a probe but it is connected to an endstop pin
Add some comments
Shift some entries to have related things together.
Conditionals.h
We have a probe (HAS_Z_MIN_PROBE) if one of the pins is defined AND one of the probes is defined.
SanityCheck.h
Add some tests if the probe is connected and if we have defined a probe.
stepper.cpp
Changes to test the probe only when it is deployed (z_probe_is_active).
Test update_endstops() when the probe is deployed.
MarlinMain.cpp
a. set and reset z_probe_is_active in deploy_z_probe(), stow_z_probe() and dock_sled()
b. set and reset z_probe_is_active in the case a z-servo is moved to a defined position. The only remaining unhandled servo move is in M280 where we do not end in a defined position. If you want to handle a probe use M401/402
c. skip deploying/stowing when already deployed/stowed in the dedicated deploy/stow functions.
d. Handle the new FIX_MOUNTED_PROBE in parallel to a servo driven probe/endstop.
To do: In another PR. handle all probes in deploy/stow_z_probe.
Sort out SERVO_LEVELING vs. HAS_SERVO_ENDSTOPS.