Commit graph

53 commits

Author SHA1 Message Date
esenapaj f260e00a72 fix spelling
Thermister -> Thermistor
2016-03-21 20:57:03 +09:00
jbrazio b82d91eca6 Added configuration example for the BQ Hephestos 2 3D printer.
Added support for BQ ZUM Mega 3D board and stock Hephestos 2 thermistor.
2016-03-06 05:51:56 -08:00
Richard Wackerbarth 4f314afaf0 Allow Thermistor #12 to be used on hotends also
//100k 0603 SMD Vishay NTCS0603E3104FXT (4.7k pullup) (calibrated for Makibox hot bed)

Caveat Emptor —- 
I’m not sure that this really makes sense,
but why keep someone from using it?
2015-12-10 06:31:31 -06:00
Scott Lahteine 0c7f7ebcfb Styling adjustments (PR#2668 & PR#2670)
Keep "astyled" reformatting
2015-10-03 22:02:45 -05:00
Fourmi e6aed7bb4e Update thermistortables for Hisens Thermistor (PR#2588) 2015-08-09 18:11:14 -05:00
Scott Lahteine 278aa15301 Add COUNT macro and apply 2015-07-22 18:16:05 -05:00
AnHardt c6d2ebe452 Extend the idea of dummy temperature sensors.
Added a second sensor and made them configurable.
2015-02-24 11:02:16 +01:00
alexborro a57869ba49 Dummy Thermistor Table for testing purposes
Am I the only one who always need to change the thermistortable.h to add
a dummy table??
Ok, it is done. Just set the thermistor to 999 and it will always read
25C. Great for Testing or Development purposes.
2015-02-22 11:02:04 -03:00
MagoKimbra 986e723eeb Add 4th extruder 2015-01-24 13:37:58 +01:00
Fourmi af3e4d7510 Update line 627 ,wrong number on thermistortables
Wrong number on line 627 > i change number "12" by the correct number "13"
Soory
2014-10-06 14:21:44 +02:00
Fourmi a664763e6f Update thermistortables.h
Add another thermistor table (13),it's a cartridge thermistor up to +300°C,use with Hotend "Simple ONE" & "All In ONE"

Thx
2014-09-27 09:05:10 +02:00
Fourmi c35736a140 Update thermistortables.h
Add another thermistor table,use with hotend "Simple ONE" & "All in ONE"
2014-09-26 21:49:07 +02:00
cocktailyogi 512f2a3136 restore Branch from Backup
sorry for that
2014-06-23 17:09:57 +02:00
Greg Tan 6e6e4e2143 Added thermistor table for the 500C thermistor shipped with the Pico hot end. 2014-06-08 09:35:04 +08:00
Cameron Lai da6b536182 Add 5DPrint D8 Driver Board info and temperature table for Makibox hot bed 2014-04-24 16:49:42 +08:00
Nutz95 ed6f4a71c5 fix wrong temptable index 2014-04-13 18:00:55 +02:00
Nutz95 3161740df9 This table is made for thermistor 3950 (can be found on ebay for cheap)
it's caracteristics are :

R25℃ ;100KΩ±1%

B Value(R25/50℃):3990K 1%
Dissipation Factor(mW/℃):1.1~1.6 In still Air
Thermal Time Constant(S):10~17 In Still Air
Operating temperature range:  (-50~+260°C)
Dimension:  1.8mm Dia X4.1mm
Lead Length  :30mm

This table was found on the following blogs:
http://cae2100.wordpress.com/2014/03/08/beta3950-thermistor-table-for-marlin/

and

http://microfabricator.com/articles/view/id/531ad7e59aad9d3131000000/beta-3950-thermistor-table-for-marlin
2014-04-13 17:03:20 +02:00
David Forrest b0093a1513 thermistortables.h: Add comments that table 60 uses beta=3950. 2014-03-26 23:41:10 -04:00
Josef Pavlik 831fc2a952 Pt100 and Pt1000 temperature sensors handling 2014-02-14 12:26:27 +01:00
daid df194f75e1 Added PT100 support for Ultiboard2 2014-01-06 11:20:03 +01:00
Nicolas Rossi 4623e78ce0 Added Honeywell thermistor 135-104LAF-J01 2013-07-30 14:02:18 +02:00
ErikZalm 9f2862ce48 Merge pull request #414 from whosawhatsis/Marlin_v1
regenerated thermistor table 7
2013-03-25 13:14:49 -07:00
Ryan Turner 7c47e7162d Adding Maker's Tool Works heated bed thermistor 2013-03-18 22:53:37 -05:00
whosawhatsis 6a61a3c0b4 missing comma in last commit 2013-03-08 16:15:49 -08:00
whosawhatsis f0aee4101a regenerated thermistor table 7
Generated with createTemperatureLookup.py. The old table crapped out at
270C, which was a problem for polycarbonate.
2013-03-08 13:41:49 -08:00
Denis B 49b2ddc8c1 Cleaned up non-standard characters 2013-02-04 01:41:40 -05:00
Daniele Sdei 3cf59f6f9a add RepRapPro Huxley thermistor tables 2013-01-14 15:36:08 +01:00
daid303 7577717b59 Fixed #336 2012-12-12 13:08:26 +01:00
daid303 52158dffcc Big temperature code update. No longer converts back and forwards between temperature and raw sample value. Reducing complexity, removing code. Also named some variables better. While keeping the safety intact and functionality the same. 2012-12-09 23:00:06 +01:00
MaikStohn 2b7b1e52b1 allow marlin internal 0°C represenation 2012-11-13 14:37:08 +01:00
Erik vd Zalm 0e89022cc3 Correct temptable_55 name. 2012-08-28 19:47:22 +02:00
Bernhard Kubicek 6b14f95b3e Merge pull request #170 from linagee/Marlin_v1
Marlin v1
2012-06-02 03:46:56 -07:00
Bernhard Kubicek b7fc14bc65 repaired thermistortable_6 by graphcial fitting of the off-slope values. see issue 179. Erik, I know you asked for no changes, but this file probably is not related and hopefully allright. 2012-05-30 14:14:36 +03:00
linagee 2e8c5049c5 Update Marlin/thermistortables.h 2012-05-20 13:18:45 -06:00
linagee 2d0d8e5272 Small correction. 2012-05-20 11:09:07 -06:00
linagee 9e9db65c3f Update Marlin/thermistortables.h 2012-05-20 05:51:29 -06:00
linagee bd966ef389 Update Marlin/thermistortables.h 2012-05-20 05:49:01 -06:00
linagee 775da3f103 Added top ratings and extended to ADC=1 for table 3 and 5. 2012-05-20 05:35:57 -06:00
linagee 96a4baa0be Update Marlin/thermistortables.h 2012-05-20 04:55:22 -06:00
linagee 2aa9f7b131 Update Marlin/thermistortables.h 2012-05-20 04:35:28 -06:00
linagee dd9144994e Tested May 19 - It works! Verified with separate thermocouple TM-902C also. 2012-05-20 04:13:29 -06:00
linagee 4c37d0d9f1 Extended range above 250C. (Operating range states up to 300C) 2012-05-20 04:01:30 -06:00
linagee 241f5a4c0e Update Marlin/thermistortables.h 2012-05-19 05:52:12 -06:00
Bernhard 57f9359a41 simplified the includes, makefile now works with arduino23 2011-12-22 14:55:45 +01:00
Denis B 4fd75dc813 Working version of multiple extruders (up to 3)
- The temperature control is pretty much complete
  (not sure what to do w/ autotemp though)
  Changed the pins assignment to clearly separate bed and extruder heaters
  and temp sensors, changed a bit how termistor tables are handled.
- The steppers control is rudimentary
  (only chanages what pins it uses depending on the active_extruder var,
   but that's enough for switching extruder in the start.gcode in the
   the profiles)
- Tested only w/ RAMPS 1.4
2011-12-06 00:09:16 -05:00
Bernhard Kubicek a9c7da06e3 and changed ultipanel to have the mm/sec and not mm/min
Merge branch 'Marlin_v1' of https://github.com/ErikZalm/Marlin into Marlin_v1

Conflicts:
	Marlin/Marlin.pde
	Marlin/ultralcd.h
2011-11-15 22:50:43 +01:00
Erik van der Zalm 04d3b5537f Merge remote-tracking branch 'origin/Marlin_v1' into Marlin_v1
Conflicts:
	Marlin/Configuration.h
	Marlin/EEPROMwrite.h
	Marlin/Marlin.h
	Marlin/Marlin.pde
	Marlin/temperature.cpp
	Marlin/temperature.h
	Marlin/thermistortables.h
2011-11-05 20:03:38 +01:00
Erik van der Zalm d15f01e1b4 Temperature changes 2011-11-05 19:21:36 +01:00
Bernhard Kubicek 40e8081623 changed end of line to windows, which seems to be the majority of developers main platform. 2011-11-05 14:19:57 +01:00
Bernhard Kubicek 00674af3a8 merge from the branch bkubicek/Marlin/zalmmerge 2011-11-05 14:13:20 +01:00