Alex Borro 2bbb68be8a Fix calculation of BAL grid fitting into the bed
The previous calc was wrong. Between N points there are only N-1 gaps,
not N.

So changing AUTO_BED_LEVELING_GRID_POINTS to
(AUTO_BED_LEVELING_GRID_POINTS-1)
2015-01-09 10:17:33 -02:00
andrewsil1 269ec9f87f Fix grammar/typos in new Configuration.h option
(For the SLOW_PWM_HEATERS option)
2015-01-07 12:41:09 -08:00
Dino Del Favero 5cfe13f240 Correct some mistakes 2015-01-06 21:55:08 +01:00
DinoMesina 6730335657 Update Configuration.h 2015-01-06 18:06:02 +01:00
Lane Roberts 2701dd8a17 Due to the fix for #1248, X and Y probe offsets must not be floats.
The compiler does not support comparing float values: "error: floating constant in preprocessor expression"
The loss in X/Y precision shouldn't matter for Z probes, as most microswitches or inductive sensors are larger than 1mm square anyway.
2014-12-31 12:34:59 -06:00
Caleb Anderson 991a74b75b Move delta calibration menu to sample delta configuration.
Turn off by default.
2014-12-29 18:03:56 -07:00
Caleb Anderson 5b336a4cdb Delta calibration menu based on http://minow.blogspot.com/index.html#4918805519571907051
To test/enable, uncomment the #define DELTA_CALIBRATION_MENU in Configuration.h
2014-12-29 10:13:00 -07:00
fmalpartida ec33df0554 Merge branch 'SAV-MkI_merge' into Development
Tested for SAV MKI and SAV 3D LCD on lewihe.
2014-12-28 19:54:06 +01:00
alexborro 3afe66bb0c Fix issues #1248, #1240
- Fixed issue when BAL area probing is shorter than it should be for
grid probing
- Warning when BAL activated with Delta Kinematics
- Fix XY_TRAVEL_SPEED when homing Z axis
2014-12-28 13:27:39 -02:00
David Forrest cf52c48d19 Configuration.m: Set PID_INTEGRAL_DRIVE_MAX from PID_MAX from BANG_MAX.
Current defaults are all 255.  If it makes sense to reduce them, they should come down together, and
be in a  PID_INTEGRAL_DRIVE_MAX <= PID_MAX <- BANG_MAX relationship.
2014-12-27 15:26:09 -05:00
alexborro d74aabf259 Revert "Change Auto_Bed_Leveling to Auto_Bed_Compensation" 2014-12-21 10:06:05 -02:00
John Davis 81568c3c6d Update Configuration.h
Changed Auto Bed Level to Auto Bed Compensation
2014-12-19 17:06:56 -05:00
Scott Lahteine 3b1f186c0c Clean up configs 2014-12-18 13:59:31 -08:00
Scott Lahteine f83d0f2a68 Defines for electronics boards
Added boards.h which contains defines for all the board numbers, plus
some shorthand macros for less typing.
2014-12-18 13:59:31 -08:00
Bo Herrmannsen 280504e2e0 Merge pull request #908 from alromh87/Marlin_v1
Support for Gen3 Monolithic electronics
2014-12-17 22:28:07 +01:00
Bo Herrmannsen 91d740e128 Merge pull request #1141 from filipmu/Filament-Sensor
Display filament sensor data on a 20x4 LCD or Graphical LCD
2014-12-17 20:38:30 +01:00
Filip Mulier d84934d8c5 Display Filament Sensor data on 20x4 LCD
Changes to support displaying the real-time filament width and the
volume factor on a 20x4 LCD.  The data is displayed on the 4th line.
First the status message is displayed for 5 seconds, and then the
filament data is displayed.  The status message can be seen by
re-selecting the info screen in the menu.
2014-11-10 21:43:58 -06:00
Filip Mulier 5c8107bcdd Commented out FILAMENT_SENSOR #define
Commented out the FILAMENT_SENSOR define so that it is not enabled by
default.  Code does not work on all hardware variants.
2014-11-09 13:26:02 -06:00
Erik van der Zalm 058e446531 Merge pull request #1037 from filipmu/Filament-Sensor
Support for a filament diameter sensor
2014-10-11 22:56:01 +02:00
Erik van der Zalm aaaf8fe8dd Merge pull request #1068 from darkjavi/Marlin_v1
Added profile for RAMPS with 2 extruders and 1 fan, no heated bed
2014-10-06 13:41:38 +02:00
Erik van der Zalm ce85515428 Merge pull request #1082 from Fourmi/Marlin_v1
Add thermistor table
2014-10-06 13:39:36 +02:00
Scott Lahteine f989bd5435 Simple code cleanup. Rename "homeing" to homing. 2014-10-05 13:20:53 -07:00
Fourmi b5dc228a7a Update configuration.h
Add another comment for thermistor 13 ,use with Hotend "Simple ONE & All In ONE"
2014-09-27 09:02:58 +02:00
Fourmi 3cbb2f56c6 Update configuration.h
Add another comment on configuration.h for the value of thermistor.
I make a pull request on thermistortables.h with my thermistor (12),but y see there is a comment on configuration with number 12 but it's not present on thermistortables.h ?

Thx
2014-09-26 22:01:06 +02:00
Javi 40ba644bb4 Added profile for RAMPS with 2 extruders and 1 fan.
modified:   Marlin/Configuration.h
	modified:   Marlin/pins.h
2014-09-06 02:53:36 +02:00
Filip Mulier fe3a09bbcf Correct analog sampling time for additional A to D sample
Adjusted the  #define PID_dT to reflect 10 A to D sample steps, vs
original 8.
2014-09-01 06:26:19 -05:00
Erik van der Zalm 018b68a5c4 Merge pull request #976 from cocktailyogi/SCARA_by_Yogi
Implemented SCARA-Maths
2014-08-28 16:32:52 +02:00
Erik van der Zalm 0fbfb1bf82 Merge pull request #991 from bonm014/patch-1
Leapfrog controller board support
2014-08-28 16:27:52 +02:00
Erik van der Zalm 68dd5e635e Merge pull request #1024 from oliasmage/Marlin_v1
Adding Z Probe via sled mounted endstop
2014-08-28 16:15:54 +02:00
Filip Mulier e3c88a5120 Filament sensor changes to config file
Update the config file for improvements and clarifying what diameter to
use in the slicer software.
2014-08-16 07:08:09 -05:00
Roxy-3DPrintBoard 0adbc79571 Fix Default Configuration so Auto Bed Leveling is off
This snapshot has the Auto Bed Leveling turned off because most Marlin
users do not have that feature.
2014-08-10 10:18:54 -05:00
Roxy-3DPrintBoard 0091865583 Z_PROBE_REPEATABILITY test
Z_PROBE_REPEATABILITY test for Auto Bed Leveling.
Implemented as M48 with extra user specified options.
Full support at
http://3dprintboard.com/showthread.php?2802-Auto_Bed_Leveling-Z-Probe-Repeatability-code
2014-08-09 15:37:23 -05:00
Filip Mulier 85649a4549 Real-time filament diameter measurement and control
This feature allows the printer to read the filament diameter
automatically and adjust the printer in real time.  Added code to read
an analog voltage that represents a filament diameter measurement.  This
measurement is delayed in a ring buffer to compensate for sensors that
are a distance away from the extruder.  The measurement is used to
adjust the volumetric_multiplier for the extruder.  Some additional g
codes (M404, M405, M406, M407) are used to set parameters and turn
on/off the control. g code M221 is updated.  Pins for RAMPS1.4, RAMBO,
and Printrboard are identified for analog input.  The configuration file
is updated with relevant user parameters.
2014-08-06 19:30:57 -05:00
Charles Bell e7707aedbc Commented out new #defines in Configuration.h. 2014-08-04 10:18:25 -04:00
Charles Bell 0a8dc0e96b Added documentation to the README.md for the sled Z probe option. CAB 2014-08-04 10:07:43 -04:00
cocktailyogi 2f4a20257c imported last Marlin changes 2014-07-20 13:49:26 +02:00
alexborro 50b4e86f75 Add "Thermal Runaway Protection" feature
This is a feature to protect your printer from burn up in flames if it
has a thermistor coming off place (this happened to a friend of mine
recently and motivated me writing this feature).

The issue: If a thermistor come off, it will read a lower temperature
than actual. The system will turn the heater on forever, burning up the
filament and anything
else around.

After the temperature reaches the target for the first time, this
feature will start measuring for how long the current temperature stays
below the target minus _HYSTERESIS (set_temperature -
THERMAL_RUNAWAY_PROTECTION_HYSTERESIS).

If it stays longer than _PERIOD, it means the thermistor temperature
cannot catch up with the target, so something *may be* wrong. Then, to
be on the safe side, the system will he halt.

Bear in mind the count down will just start AFTER the first time the
thermistor temperature is over the target, so you will have no problem
if your extruder heater takes 2 minutes to hit the target on heating.
2014-07-18 15:28:01 +02:00
bonm014 b5417be109 Update Configuration.h
Leapfrog added to the board list
2014-07-03 21:03:22 +02:00
alexborro 43c298a7a9 Add "Thermal Runaway Protection" feature
This is a feature to protect your printer from burn up in flames if it
has a thermistor coming off place (this happened to a friend of mine
recently and motivated me writing this feature).

The issue: If a thermistor come off, it will read a lower temperature
than actual. The system will turn the heater on forever, burning up the
filament and anything
else around.

After the temperature reaches the target for the first time, this
feature will start measuring for how long the current temperature stays
below the target minus _HYSTERESIS (set_temperature -
THERMAL_RUNAWAY_PROTECTION_HYSTERESIS).

If it stays longer than _PERIOD, it means the thermistor temperature
cannot catch up with the target, so something *may be* wrong. Then, to
be on the safe side, the system will he halt.

Bear in mind the count down will just start AFTER the first time the
thermistor temperature is over the target, so you will have no problem
if your extruder heater takes 2 minutes to hit the target on heating.
2014-06-30 15:22:49 -03:00
cocktailyogi 512f2a3136 restore Branch from Backup
sorry for that
2014-06-23 17:09:57 +02:00
Greg Tan 6e6e4e2143 Added thermistor table for the 500C thermistor shipped with the Pico hot end. 2014-06-08 09:35:04 +08:00
Dim3nsioneer 8a32c5395b renaming the disable inactive extruder feature 2014-06-02 14:07:02 +02:00
Dim3nsioneer 29e7639933 Add switch unused feeder(s) off
Having the non-active feeder motors powered on all the time is not
necessary. A feature to deactivate the unused feeder motors has been
implemented. The feature is enabled on default but can be switched off
in the configuration.
2014-06-02 08:13:09 +02:00
David Forrest 09b84faa00 Configuration.h, pins.h: Add MOTHERBOARD 84 for Teensy++2.0 2014-05-29 17:19:16 -04:00
Alejandro Romero 1c9a70cee9 Support for Gen3 Monolithic electronics
Techzone Monotronics support, ignoring the tip manager and using fan connector as on Sprinter FW
TODO: Add support for tipmanager
2014-05-06 19:24:20 -05:00
daid 2acd3792fc Merge branch 'Marlin_v1' of github.com:ErikZalm/Marlin into Marlin_v1 2014-05-01 12:03:47 +02:00
daid 8b4c4aa5c3 Add feature to check&retry CRC read errors on SD. 2014-05-01 12:03:41 +02:00
Cameron Lai da6b536182 Add 5DPrint D8 Driver Board info and temperature table for Makibox hot bed 2014-04-24 16:49:42 +08:00
Nutz95 3161740df9 This table is made for thermistor 3950 (can be found on ebay for cheap)
it's caracteristics are :

R25℃ ;100KΩ±1%

B Value(R25/50℃):3990K 1%
Dissipation Factor(mW/℃):1.1~1.6 In still Air
Thermal Time Constant(S):10~17 In Still Air
Operating temperature range:  (-50~+260°C)
Dimension:  1.8mm Dia X4.1mm
Lead Length  :30mm

This table was found on the following blogs:
http://cae2100.wordpress.com/2014/03/08/beta3950-thermistor-table-for-marlin/

and

http://microfabricator.com/articles/view/id/531ad7e59aad9d3131000000/beta-3950-thermistor-table-for-marlin
2014-04-13 17:03:20 +02:00
Gabe Rosenhouse d3f305332a Allowable range now includes default value 2014-04-06 19:45:56 -05:00