This data corruption problem is very difficult. Just changing the code
a little bit changes whether the problem even happens and what is
affected. I need these changes in the main branch so I can operate with
the extra debug code always available and turned on.
Everything is setup such that if M100 is turned off or DEBUG(ECHO) is
turned off, the code is not affected. M100 has been made a little bit
more inteligent so it can display the serial command buffers in a more
meaningful way (because the data corruption seems to often times end up
in that area).
Configuration_store.cpp - changed a couple of print statements so the
values were printed. The old method resulted in the formula being
printed.
ubl_G29
1) added support for R option to P4. Now probes all points unless R is
present and the number is greater than 0.
2) P2 - moved map print statement so it showed the point that was
currently being probed, The old location did this only for the first
point.
3) P4 - Moved the map print for the same reason.
ultralcd.cpp - changed "Mesh Editor :" to "Mesh Editor" because the LCD
draw routine puts a ":" in automatically so you end up with an extra ":"
using the old message.
- On `DELTA` the `M665 H` option supplants `M206`
- On `DELTA` `NO_WORKSPACE_OFFSETS` only reverts `G92` behavior
- Spawn 4 conditionals based on `NO_WORKSPACE_OFFSETS`
- Optimize coordinate space conversion for `DELTA` workspace
- To keep EEPROM version, retain `home_offset[XYZ]`, just ignore XY
Firmware was forgetting the z_fade_height in Planner, set by M420 Z<f>,
after each reset or loading settings from EEPROM. Added the float
z_fade_height to EEPROM-Storage, now remembers the value.
The offset for Z_DUAL_ENDSTOP (z_endstop_adj) is already in Marlin.
This PR just makes it a configuration item.
z_endstop_adj is initialized in two places so both had to be modified.