muele-marlin/Marlin/src/feature/bedlevel/bedlevel.cpp
2020-10-16 19:55:18 -05:00

240 lines
7 KiB
C++

/**
* Marlin 3D Printer Firmware
* Copyright (c) 2020 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl.
* Copyright (c) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <https://www.gnu.org/licenses/>.
*
*/
#include "../../inc/MarlinConfig.h"
#if HAS_LEVELING
#include "bedlevel.h"
#include "../../module/planner.h"
#if EITHER(MESH_BED_LEVELING, PROBE_MANUALLY)
#include "../../module/motion.h"
#endif
#if ENABLED(PROBE_MANUALLY)
bool g29_in_progress = false;
#endif
#if ENABLED(LCD_BED_LEVELING)
#include "../../lcd/marlinui.h"
#endif
#define DEBUG_OUT ENABLED(DEBUG_LEVELING_FEATURE)
#include "../../core/debug_out.h"
#if ENABLED(EXTENSIBLE_UI)
#include "../../lcd/extui/ui_api.h"
#endif
bool leveling_is_valid() {
return TERN1(MESH_BED_LEVELING, mbl.has_mesh())
&& TERN1(AUTO_BED_LEVELING_BILINEAR, !!bilinear_grid_spacing.x)
&& TERN1(AUTO_BED_LEVELING_UBL, ubl.mesh_is_valid());
}
/**
* Turn bed leveling on or off, fixing the current
* position as-needed.
*
* Disable: Current position = physical position
* Enable: Current position = "unleveled" physical position
*/
void set_bed_leveling_enabled(const bool enable/*=true*/) {
const bool can_change = TERN1(AUTO_BED_LEVELING_BILINEAR, !enable || leveling_is_valid());
if (can_change && enable != planner.leveling_active) {
planner.synchronize();
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
// Force bilinear_z_offset to re-calculate next time
const xyz_pos_t reset { -9999.999, -9999.999, 0 };
(void)bilinear_z_offset(reset);
#endif
if (planner.leveling_active) { // leveling from on to off
if (DEBUGGING(LEVELING)) DEBUG_POS("Leveling ON", current_position);
// change unleveled current_position to physical current_position without moving steppers.
planner.apply_leveling(current_position);
planner.leveling_active = false; // disable only AFTER calling apply_leveling
if (DEBUGGING(LEVELING)) DEBUG_POS("...Now OFF", current_position);
}
else { // leveling from off to on
if (DEBUGGING(LEVELING)) DEBUG_POS("Leveling OFF", current_position);
planner.leveling_active = true; // enable BEFORE calling unapply_leveling, otherwise ignored
// change physical current_position to unleveled current_position without moving steppers.
planner.unapply_leveling(current_position);
if (DEBUGGING(LEVELING)) DEBUG_POS("...Now ON", current_position);
}
sync_plan_position();
}
}
TemporaryBedLevelingState::TemporaryBedLevelingState(const bool enable) : saved(planner.leveling_active) {
set_bed_leveling_enabled(enable);
}
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
void set_z_fade_height(const float zfh, const bool do_report/*=true*/) {
if (planner.z_fade_height == zfh) return;
const bool leveling_was_active = planner.leveling_active;
set_bed_leveling_enabled(false);
planner.set_z_fade_height(zfh);
if (leveling_was_active) {
const xyz_pos_t oldpos = current_position;
set_bed_leveling_enabled(true);
if (do_report && oldpos != current_position)
report_current_position();
}
}
#endif // ENABLE_LEVELING_FADE_HEIGHT
/**
* Reset calibration results to zero.
*/
void reset_bed_level() {
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPGM("reset_bed_level");
#if ENABLED(AUTO_BED_LEVELING_UBL)
ubl.reset();
#else
set_bed_leveling_enabled(false);
#if ENABLED(MESH_BED_LEVELING)
mbl.reset();
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
bilinear_start.reset();
bilinear_grid_spacing.reset();
GRID_LOOP(x, y) {
z_values[x][y] = NAN;
TERN_(EXTENSIBLE_UI, ExtUI::onMeshUpdate(x, y, 0));
}
#elif ABL_PLANAR
planner.bed_level_matrix.set_to_identity();
#endif
#endif
}
#if EITHER(AUTO_BED_LEVELING_BILINEAR, MESH_BED_LEVELING)
/**
* Enable to produce output in JSON format suitable
* for SCAD or JavaScript mesh visualizers.
*
* Visualize meshes in OpenSCAD using the included script.
*
* buildroot/shared/scripts/MarlinMesh.scad
*/
//#define SCAD_MESH_OUTPUT
/**
* Print calibration results for plotting or manual frame adjustment.
*/
void print_2d_array(const uint8_t sx, const uint8_t sy, const uint8_t precision, element_2d_fn fn) {
#ifndef SCAD_MESH_OUTPUT
LOOP_L_N(x, sx) {
serial_spaces(precision + (x < 10 ? 3 : 2));
SERIAL_ECHO(int(x));
}
SERIAL_EOL();
#endif
#ifdef SCAD_MESH_OUTPUT
SERIAL_ECHOLNPGM("measured_z = ["); // open 2D array
#endif
LOOP_L_N(y, sy) {
#ifdef SCAD_MESH_OUTPUT
SERIAL_ECHOPGM(" ["); // open sub-array
#else
if (y < 10) SERIAL_CHAR(' ');
SERIAL_ECHO(int(y));
#endif
LOOP_L_N(x, sx) {
SERIAL_CHAR(' ');
const float offset = fn(x, y);
if (!isnan(offset)) {
if (offset >= 0) SERIAL_CHAR('+');
SERIAL_ECHO_F(offset, int(precision));
}
else {
#ifdef SCAD_MESH_OUTPUT
for (uint8_t i = 3; i < precision + 3; i++)
SERIAL_CHAR(' ');
SERIAL_ECHOPGM("NAN");
#else
LOOP_L_N(i, precision + 3)
SERIAL_CHAR(i ? '=' : ' ');
#endif
}
#ifdef SCAD_MESH_OUTPUT
if (x < sx - 1) SERIAL_CHAR(',');
#endif
}
#ifdef SCAD_MESH_OUTPUT
SERIAL_CHAR(' ', ']'); // close sub-array
if (y < sy - 1) SERIAL_CHAR(',');
#endif
SERIAL_EOL();
}
#ifdef SCAD_MESH_OUTPUT
SERIAL_ECHOPGM("];"); // close 2D array
#endif
SERIAL_EOL();
}
#endif // AUTO_BED_LEVELING_BILINEAR || MESH_BED_LEVELING
#if EITHER(MESH_BED_LEVELING, PROBE_MANUALLY)
void _manual_goto_xy(const xy_pos_t &pos) {
#ifdef MANUAL_PROBE_START_Z
constexpr float startz = _MAX(0, MANUAL_PROBE_START_Z);
#if MANUAL_PROBE_HEIGHT > 0
do_blocking_move_to_xy_z(pos, MANUAL_PROBE_HEIGHT);
do_blocking_move_to_z(startz);
#else
do_blocking_move_to_xy_z(pos, startz);
#endif
#elif MANUAL_PROBE_HEIGHT > 0
const float prev_z = current_position.z;
do_blocking_move_to_xy_z(pos, MANUAL_PROBE_HEIGHT);
do_blocking_move_to_z(prev_z);
#else
do_blocking_move_to_xy(pos);
#endif
current_position = pos;
TERN_(LCD_BED_LEVELING, ui.wait_for_move = false);
}
#endif
#endif // HAS_LEVELING