muele-marlin/Marlin/ubl_G29.cpp
2017-05-07 21:28:54 -05:00

1703 lines
72 KiB
C++

/**
* Marlin 3D Printer Firmware
* Copyright (C) 2016 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl.
* Copyright (C) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*
*/
#include "MarlinConfig.h"
#if ENABLED(AUTO_BED_LEVELING_UBL)
//#include "vector_3.h"
//#include "qr_solve.h"
#include "ubl.h"
#include "Marlin.h"
#include "hex_print_routines.h"
#include "configuration_store.h"
#include "ultralcd.h"
#include "stepper.h"
#include <math.h>
#include "least_squares_fit.h"
extern float destination[XYZE];
extern float current_position[XYZE];
void lcd_return_to_status();
bool lcd_clicked();
void lcd_implementation_clear();
void lcd_mesh_edit_setup(float initial);
float lcd_mesh_edit();
void lcd_z_offset_edit_setup(float);
float lcd_z_offset_edit();
extern float meshedit_done;
extern long babysteps_done;
extern float code_value_float();
extern uint8_t code_value_byte();
extern bool code_value_bool();
extern bool code_has_value();
extern float probe_pt(float x, float y, bool, int);
extern bool set_probe_deployed(bool);
void smart_fill_mesh();
bool ProbeStay = true;
#define SIZE_OF_LITTLE_RAISE 0
#define BIG_RAISE_NOT_NEEDED 0
extern void lcd_quick_feedback();
/**
* G29: Unified Bed Leveling by Roxy
*
* Parameters understood by this leveling system:
*
* A Activate Activate the Unified Bed Leveling system.
*
* B # Business Use the 'Business Card' mode of the Manual Probe subsystem. This is invoked as
* G29 P2 B The mode of G29 P2 allows you to use a bussiness card or recipe card
* as a shim that the nozzle will pinch as it is lowered. The idea is that you
* can easily feel the nozzle getting to the same height by the amount of resistance
* the business card exhibits to movement. You should try to achieve the same amount
* of resistance on each probed point to facilitate accurate and repeatable measurements.
* You should be very careful not to drive the nozzle into the bussiness card with a
* lot of force as it is very possible to cause damage to your printer if your are
* careless. If you use the B option with G29 P2 B you can leave the number parameter off
* on its first use to enable measurement of the business card thickness. Subsequent usage
* of the B parameter can have the number previously measured supplied to the command.
* Incidently, you are much better off using something like a Spark Gap feeler gauge than
* something that compresses like a Business Card.
*
* C Continue Continue, Constant, Current Location. This is not a primary command. C is used to
* further refine the behaviour of several other commands. Issuing a G29 P1 C will
* continue the generation of a partially constructed Mesh without invalidating what has
* been done. Issuing a G29 P2 C will tell the Manual Probe subsystem to use the current
* location in its search for the closest unmeasured Mesh Point. When used with a G29 Z C
* it indicates to use the current location instead of defaulting to the center of the print bed.
*
* D Disable Disable the Unified Bed Leveling system.
*
* E Stow_probe Stow the probe after each sampled point.
*
* F # Fade * Fade the amount of Mesh Based Compensation over a specified height. At the
* specified height, no correction is applied and natural printer kenimatics take over. If no
* number is specified for the command, 10mm is assumed to be reasonable.
*
* H # Height Specify the Height to raise the nozzle after each manual probe of the bed. The
* default is 5mm.
*
* I # Invalidate Invalidate specified number of Mesh Points. The nozzle location is used unless
* the X and Y parameter are used. If no number is specified, only the closest Mesh
* point to the location is invalidated. The M parameter is available as well to produce
* a map after the operation. This command is useful to invalidate a portion of the
* Mesh so it can be adjusted using other tools in the Unified Bed Leveling System. When
* attempting to invalidate an isolated bad point in the mesh, the M option will indicate
* where the nozzle is positioned in the Mesh with (#). You can move the nozzle around on
* the bed and use this feature to select the center of the area (or cell) you want to
* invalidate.
*
* J # Grid * Perform a Grid Based Leveling of the current Mesh using a grid with n points on a side.
*
* j EEPROM Dump This function probably goes away after debug is complete.
*
* K # Kompare Kompare current Mesh with stored Mesh # replacing current Mesh with the result. This
* command literally performs a diff between two Meshes.
*
* L Load * Load Mesh from the previously activated location in the EEPROM.
*
* L # Load * Load Mesh from the specified location in the EEPROM. Set this location as activated
* for subsequent Load and Store operations.
*
* O Map * Display the Mesh Map Topology.
* The parameter can be specified alone (ie. G29 O) or in combination with many of the
* other commands. The Mesh Map option works with all of the Phase
* commands (ie. G29 P4 R 5 X 50 Y100 C -.1 O) The Map parameter can also of a Map Type
* specified. A map type of 0 is the default is user readable. A map type of 1 can
* be specified and is suitable to Cut & Paste into Excel to allow graphing of the user's
* mesh.
*
* The P or Phase commands are used for the bulk of the work to setup a Mesh. In general, your Mesh will
* start off being initialized with a G29 P0 or a G29 P1. Further refinement of the Mesh happens with
* each additional Phase that processes it.
*
* P0 Phase 0 Zero Mesh Data and turn off the Mesh Compensation System. This reverts the
* 3D Printer to the same state it was in before the Unified Bed Leveling Compensation
* was turned on. Setting the entire Mesh to Zero is a special case that allows
* a subsequent G or T leveling operation for backward compatibility.
*
* P1 Phase 1 Invalidate entire Mesh and continue with automatic generation of the Mesh data using
* the Z-Probe. Depending upon the values of DELTA_PROBEABLE_RADIUS and
* DELTA_PRINTABLE_RADIUS some area of the bed will not have Mesh Data automatically
* generated. This will be handled in Phase 2. If the Phase 1 command is given the
* C (Continue) parameter it does not invalidate the Mesh prior to automatically
* probing needed locations. This allows you to invalidate portions of the Mesh but still
* use the automatic probing capabilities of the Unified Bed Leveling System. An X and Y
* parameter can be given to prioritize where the command should be trying to measure points.
* If the X and Y parameters are not specified the current probe position is used. Phase 1
* allows you to specify the M (Map) parameter so you can watch the generation of the Mesh.
* Phase 1 also watches for the LCD Panel's Encoder Switch being held in a depressed state.
* It will suspend generation of the Mesh if it sees the user request that. (This check is
* only done between probe points. You will need to press and hold the switch until the
* Phase 1 command can detect it.)
*
* P2 Phase 2 Probe areas of the Mesh that can't be automatically handled. Phase 2 respects an H
* parameter to control the height between Mesh points. The default height for movement
* between Mesh points is 5mm. A smaller number can be used to make this part of the
* calibration less time consuming. You will be running the nozzle down until it just barely
* touches the glass. You should have the nozzle clean with no plastic obstructing your view.
* Use caution and move slowly. It is possible to damage your printer if you are careless.
* Note that this command will use the configuration #define SIZE_OF_LITTLE_RAISE if the
* nozzle is moving a distance of less than BIG_RAISE_NOT_NEEDED.
*
* The H parameter can be set negative if your Mesh dips in a large area. You can press
* and hold the LCD Panel's encoder wheel to terminate the current Phase 2 command. You
* can then re-issue the G29 P 2 command with an H parameter that is more suitable for the
* area you are manually probing. Note that the command tries to start you in a corner
* of the bed where movement will be predictable. You can force the location to be used in
* the distance calculations by using the X and Y parameters. You may find it is helpful to
* print out a Mesh Map (G29 O) to understand where the mesh is invalidated and where
* the nozzle will need to move in order to complete the command. The C parameter is
* available on the Phase 2 command also and indicates the search for points to measure should
* be done based on the current location of the nozzle.
*
* A B parameter is also available for this command and described up above. It places the
* manual probe subsystem into Business Card mode where the thickness of a business care is
* measured and then used to accurately set the nozzle height in all manual probing for the
* duration of the command. (S for Shim mode would be a better parameter name, but S is needed
* for Save or Store of the Mesh to EEPROM) A Business card can be used, but you will have
* better results if you use a flexible Shim that does not compress very much. That makes it
* easier for you to get the nozzle to press with similar amounts of force against the shim so you
* can get accurate measurements. As you are starting to touch the nozzle against the shim try
* to get it to grasp the shim with the same force as when you measured the thickness of the
* shim at the start of the command.
*
* Phase 2 allows the O (Map) parameter to be specified. This helps the user see the progression
* of the Mesh being built.
*
* P3 Phase 3 Fill the unpopulated regions of the Mesh with a fixed value. There are two different paths the
* user can go down. If the user specifies the value using the C parameter, the closest invalid
* mesh points to the nozzle will be filled. The user can specify a repeat count using the R
* parameter with the C version of the command.
*
* A second version of the fill command is available if no C constant is specified. Not
* specifying a C constant will invoke the 'Smart Fill' algorithm. The G29 P3 command will search
* from the edges of the mesh inward looking for invalid mesh points. It will look at the next
* several mesh points to determine if the print bed is sloped up or down. If the bed is sloped
* upward from the invalid mesh point, it will be replaced with the value of the nearest mesh point.
* If the bed is sloped downward from the invalid mesh point, it will be replaced with a value that
* puts all three points in a line. The second version of the G29 P3 command is a quick, easy and
* usually safe way to populate the unprobed regions of your mesh so you can continue to the G26
* Mesh Validation Pattern phase. Please note that you are populating your mesh with unverified
* numbers. You should use some scrutiny and caution.
*
* P4 Phase 4 Fine tune the Mesh. The Delta Mesh Compensation System assume the existance of
* an LCD Panel. It is possible to fine tune the mesh without the use of an LCD Panel.
* (More work and details on doing this later!)
* The System will search for the closest Mesh Point to the nozzle. It will move the
* nozzle to this location. The user can use the LCD Panel to carefully adjust the nozzle
* so it is just barely touching the bed. When the user clicks the control, the System
* will lock in that height for that point in the Mesh Compensation System.
*
* Phase 4 has several additional parameters that the user may find helpful. Phase 4
* can be started at a specific location by specifying an X and Y parameter. Phase 4
* can be requested to continue the adjustment of Mesh Points by using the R(epeat)
* parameter. If the Repetition count is not specified, it is assumed the user wishes
* to adjust the entire matrix. The nozzle is moved to the Mesh Point being edited.
* The command can be terminated early (or after the area of interest has been edited) by
* pressing and holding the encoder wheel until the system recognizes the exit request.
* Phase 4's general form is G29 P4 [R # of points] [X position] [Y position]
*
* Phase 4 is intended to be used with the G26 Mesh Validation Command. Using the
* information left on the printer's bed from the G26 command it is very straight forward
* and easy to fine tune the Mesh. One concept that is important to remember and that
* will make using the Phase 4 command easy to use is this: You are editing the Mesh Points.
* If you have too little clearance and not much plastic was extruded in an area, you want to
* LOWER the Mesh Point at the location. If you did not get good adheasion, you want to
* RAISE the Mesh Point at that location.
*
*
* P5 Phase 5 Find Mean Mesh Height and Standard Deviation. Typically, it is easier to use and
* work with the Mesh if it is Mean Adjusted. You can specify a C parameter to
* Correct the Mesh to a 0.00 Mean Height. Adding a C parameter will automatically
* execute a G29 P6 C <mean height>.
*
* P6 Phase 6 Shift Mesh height. The entire Mesh's height is adjusted by the height specified
* with the C parameter. Being able to adjust the height of a Mesh is useful tool. It
* can be used to compensate for poorly calibrated Z-Probes and other errors. Ideally,
* you should have the Mesh adjusted for a Mean Height of 0.00 and the Z-Probe measuring
* 0.000 at the Z Home location.
*
* Q Test * Load specified Test Pattern to assist in checking correct operation of system. This
* command is not anticipated to be of much value to the typical user. It is intended
* for developers to help them verify correct operation of the Unified Bed Leveling System.
*
* R # Repeat Repeat this command the specified number of times. If no number is specified the
* command will be repeated GRID_MAX_POINTS_X * GRID_MAX_POINTS_Y times.
*
* S Store Store the current Mesh in the Activated area of the EEPROM. It will also store the
* current state of the Unified Bed Leveling system in the EEPROM.
*
* S # Store Store the current Mesh at the specified location in EEPROM. Activate this location
* for subsequent Load and Store operations. Valid storage slot numbers begin at 0 and
* extend to a limit related to the available EEPROM storage.
*
* S -1 Store Store the current Mesh as a print out that is suitable to be feed back into the system
* at a later date. The GCode output can be saved and later replayed by the host software
* to reconstruct the current mesh on another machine.
*
* T 3-Point Perform a 3 Point Bed Leveling on the current Mesh
*
* U Unlevel Perform a probe of the outer perimeter to assist in physically leveling unlevel beds.
* Only used for G29 P1 O U It will speed up the probing of the edge of the bed. This
* is useful when the entire bed does not need to be probed because it will be adjusted.
*
* W What? Display valuable data the Unified Bed Leveling System knows.
*
* X # * * X Location for this line of commands
*
* Y # * * Y Location for this line of commands
*
* Z Zero * Probes to set the Z Height of the nozzle. The entire Mesh can be raised or lowered
* by just doing a G29 Z
*
* Z # Zero * The entire Mesh can be raised or lowered to conform with the specified difference.
* zprobe_zoffset is added to the calculation.
*
*
* Release Notes:
* You MUST do M502, M500 to initialize the storage. Failure to do this will cause all
* kinds of problems. Enabling EEPROM Storage is highly recommended. With EEPROM Storage
* of the mesh, you are limited to 3-Point and Grid Leveling. (G29 P0 T and G29 P0 G
* respectively.)
*
* When you do a G28 and then a G29 P1 to automatically build your first mesh, you are going to notice
* the Unified Bed Leveling probes points further and further away from the starting location. (The
* starting location defaults to the center of the bed.) The original Grid and Mesh leveling used
* a Zig Zag pattern. The new pattern is better, especially for people with Delta printers. This
* allows you to get the center area of the Mesh populated (and edited) quicker. This allows you to
* perform a small print and check out your settings quicker. You do not need to populate the
* entire mesh to use it. (You don't want to spend a lot of time generating a mesh only to realize
* you don't have the resolution or zprobe_zoffset set correctly. The Mesh generation
* gathers points closest to where the nozzle is located unless you specify an (X,Y) coordinate pair.
*
* The Unified Bed Leveling uses a lot of EEPROM storage to hold its data. And it takes some effort
* to get this Mesh data correct for a user's printer. We do not want this data destroyed as
* new versions of Marlin add or subtract to the items stored in EEPROM. So, for the benefit of
* the users, we store the Mesh data at the end of the EEPROM and do not keep it contiguous with the
* other data stored in the EEPROM. (For sure the developers are going to complain about this, but
* this is going to be helpful to the users!)
*
* The foundation of this Bed Leveling System is built on Epatel's Mesh Bed Leveling code. A big
* 'Thanks!' to him and the creators of 3-Point and Grid Based leveling. Combining their contributions
* we now have the functionality and features of all three systems combined.
*/
#define USE_NOZZLE_AS_REFERENCE 0
#define USE_PROBE_AS_REFERENCE 1
// The simple parameter flags and values are 'static' so parameter parsing can be in a support routine.
static int g29_verbose_level, phase_value, repetition_cnt,
storage_slot = 0, map_type, grid_size;
static bool repeat_flag, c_flag, x_flag, y_flag;
static float x_pos, y_pos, measured_z, card_thickness = 0.0, ubl_constant = 0.0;
extern void lcd_setstatus(const char* message, const bool persist);
extern void lcd_setstatuspgm(const char* message, const uint8_t level);
void __attribute__((optimize("O0"))) gcode_G29() {
if (ubl.eeprom_start < 0) {
SERIAL_PROTOCOLLNPGM("?You need to enable your EEPROM and initialize it");
SERIAL_PROTOCOLLNPGM("with M502, M500, M501 in that order.\n");
return;
}
if (!code_seen('N') && axis_unhomed_error(true, true, true)) // Don't allow auto-leveling without homing first
home_all_axes();
if (g29_parameter_parsing()) return; // abort if parsing the simple parameters causes a problem,
// Invalidate Mesh Points. This command is a little bit asymetrical because
// it directly specifies the repetition count and does not use the 'R' parameter.
if (code_seen('I')) {
uint8_t cnt = 0;
repetition_cnt = code_has_value() ? code_value_int() : 1;
while (repetition_cnt--) {
if (cnt > 20) { cnt = 0; idle(); }
const mesh_index_pair location = find_closest_mesh_point_of_type(REAL, x_pos, y_pos, USE_NOZZLE_AS_REFERENCE, NULL, false);
if (location.x_index < 0) {
SERIAL_PROTOCOLLNPGM("Entire Mesh invalidated.\n");
break; // No more invalid Mesh Points to populate
}
ubl.z_values[location.x_index][location.y_index] = NAN;
cnt++;
}
SERIAL_PROTOCOLLNPGM("Locations invalidated.\n");
}
if (code_seen('Q')) {
const int test_pattern = code_has_value() ? code_value_int() : -1;
if (!WITHIN(test_pattern, 0, 2)) {
SERIAL_PROTOCOLLNPGM("Invalid test_pattern value. (0-2)\n");
return;
}
SERIAL_PROTOCOLLNPGM("Loading test_pattern values.\n");
switch (test_pattern) {
case 0:
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) { // Create a bowl shape - similar to
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) { // a poorly calibrated Delta.
const float p1 = 0.5 * (GRID_MAX_POINTS_X) - x,
p2 = 0.5 * (GRID_MAX_POINTS_Y) - y;
ubl.z_values[x][y] += 2.0 * HYPOT(p1, p2);
}
}
break;
case 1:
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) { // Create a diagonal line several Mesh cells thick that is raised
ubl.z_values[x][x] += 9.999;
ubl.z_values[x][x + (x < GRID_MAX_POINTS_Y - 1) ? 1 : -1] += 9.999; // We want the altered line several mesh points thick
}
break;
case 2:
// Allow the user to specify the height because 10mm is a little extreme in some cases.
for (uint8_t x = (GRID_MAX_POINTS_X) / 3; x < 2 * (GRID_MAX_POINTS_X) / 3; x++) // Create a rectangular raised area in
for (uint8_t y = (GRID_MAX_POINTS_Y) / 3; y < 2 * (GRID_MAX_POINTS_Y) / 3; y++) // the center of the bed
ubl.z_values[x][y] += code_seen('C') ? ubl_constant : 9.99;
break;
}
}
if (code_seen('J')) {
ubl.save_ubl_active_state_and_disable();
ubl.tilt_mesh_based_on_probed_grid(code_seen('O') || code_seen('M'));
ubl.restore_ubl_active_state_and_leave();
}
if (code_seen('P')) {
if (WITHIN(phase_value, 0, 1) && ubl.state.eeprom_storage_slot == -1) {
ubl.state.eeprom_storage_slot = 0;
SERIAL_PROTOCOLLNPGM("Default storage slot 0 selected.\n");
}
switch (phase_value) {
case 0:
//
// Zero Mesh Data
//
ubl.reset();
SERIAL_PROTOCOLLNPGM("Mesh zeroed.\n");
break;
case 1:
//
// Invalidate Entire Mesh and Automatically Probe Mesh in areas that can be reached by the probe
//
if (!code_seen('C')) {
ubl.invalidate();
SERIAL_PROTOCOLLNPGM("Mesh invalidated. Probing mesh.\n");
}
if (g29_verbose_level > 1) {
SERIAL_PROTOCOLPAIR("Probing Mesh Points Closest to (", x_pos);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL(y_pos);
SERIAL_PROTOCOLLNPGM(").\n");
}
ubl.probe_entire_mesh(x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER,
code_seen('O') || code_seen('M'), code_seen('E'), code_seen('U'));
break;
case 2: {
//
// Manually Probe Mesh in areas that can't be reached by the probe
//
SERIAL_PROTOCOLLNPGM("Manually probing unreachable mesh locations.\n");
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
if (!x_flag && !y_flag) {
/**
* Use a good default location for the path.
* The flipped > and < operators in these comparisons is intentional.
* It should cause the probed points to follow a nice path on Cartesian printers.
* It may make sense to have Delta printers default to the center of the bed.
* Until that is decided, this can be forced with the X and Y parameters.
*/
x_pos = X_PROBE_OFFSET_FROM_EXTRUDER > 0 ? UBL_MESH_MAX_X : UBL_MESH_MIN_X;
y_pos = Y_PROBE_OFFSET_FROM_EXTRUDER < 0 ? UBL_MESH_MAX_Y : UBL_MESH_MIN_Y;
}
if (code_seen('C')) {
x_pos = current_position[X_AXIS];
y_pos = current_position[Y_AXIS];
}
const float height = code_seen('H') && code_has_value() ? code_value_float() : Z_CLEARANCE_BETWEEN_PROBES;
if (code_seen('B')) {
card_thickness = code_has_value() ? code_value_float() : measure_business_card_thickness(height);
if (fabs(card_thickness) > 1.5) {
SERIAL_PROTOCOLLNPGM("?Error in Business Card measurement.\n");
return;
}
}
manually_probe_remaining_mesh(x_pos, y_pos, height, card_thickness, code_seen('O') || code_seen('M'));
SERIAL_PROTOCOLLNPGM("G29 P2 finished.");
} break;
case 3: {
/**
* Populate invalid mesh areas. Proceed with caution.
* Two choices are available:
* - Specify a constant with the 'C' parameter.
* - Allow 'G29 P3' to choose a 'reasonable' constant.
*/
if (c_flag) {
while (repetition_cnt--) {
const mesh_index_pair location = find_closest_mesh_point_of_type(INVALID, x_pos, y_pos, USE_NOZZLE_AS_REFERENCE, NULL, false);
if (location.x_index < 0) break; // No more invalid Mesh Points to populate
ubl.z_values[location.x_index][location.y_index] = ubl_constant;
}
break;
}
else
smart_fill_mesh(); // Do a 'Smart' fill using nearby known values
} break;
case 4:
//
// Fine Tune (i.e., Edit) the Mesh
//
fine_tune_mesh(x_pos, y_pos, code_seen('O') || code_seen('M'));
break;
case 5: ubl.find_mean_mesh_height(); break;
case 6: ubl.shift_mesh_height(); break;
}
}
if (code_seen('T')) {
float z1 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_1_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_1_Y), false, g29_verbose_level),
z2 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_2_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_2_Y), false, g29_verbose_level),
z3 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_3_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_3_Y), true, g29_verbose_level);
// We need to adjust z1, z2, z3 by the Mesh Height at these points. Just because they are non-zero doesn't mean
// the Mesh is tilted! (We need to compensate each probe point by what the Mesh says that location's height is)
ubl.save_ubl_active_state_and_disable();
z1 -= ubl.get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_1_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_1_Y)) /* + zprobe_zoffset */ ;
z2 -= ubl.get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_2_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_2_Y)) /* + zprobe_zoffset */ ;
z3 -= ubl.get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_3_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_3_Y)) /* + zprobe_zoffset */ ;
do_blocking_move_to_xy(0.5 * (UBL_MESH_MAX_X - (UBL_MESH_MIN_X)), 0.5 * (UBL_MESH_MAX_Y - (UBL_MESH_MIN_Y)));
ubl.tilt_mesh_based_on_3pts(z1, z2, z3);
ubl.restore_ubl_active_state_and_leave();
}
//
// Much of the 'What?' command can be eliminated. But until we are fully debugged, it is
// good to have the extra information. Soon... we prune this to just a few items
//
if (code_seen('W')) g29_what_command();
//
// When we are fully debugged, the EEPROM dump command will get deleted also. But
// right now, it is good to have the extra information. Soon... we prune this.
//
if (code_seen('j')) g29_eeprom_dump(); // EEPROM Dump
//
// When we are fully debugged, this may go away. But there are some valid
// use cases for the users. So we can wait and see what to do with it.
//
if (code_seen('K')) // Kompare Current Mesh Data to Specified Stored Mesh
g29_compare_current_mesh_to_stored_mesh();
//
// Load a Mesh from the EEPROM
//
if (code_seen('L')) { // Load Current Mesh Data
storage_slot = code_has_value() ? code_value_int() : ubl.state.eeprom_storage_slot;
const int16_t j = (UBL_LAST_EEPROM_INDEX - ubl.eeprom_start) / sizeof(ubl.z_values);
if (!WITHIN(storage_slot, 0, j - 1) || ubl.eeprom_start <= 0) {
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available for use.\n");
return;
}
ubl.load_mesh(storage_slot);
ubl.state.eeprom_storage_slot = storage_slot;
SERIAL_PROTOCOLLNPGM("Done.\n");
}
//
// Store a Mesh in the EEPROM
//
if (code_seen('S')) { // Store (or Save) Current Mesh Data
storage_slot = code_has_value() ? code_value_int() : ubl.state.eeprom_storage_slot;
if (storage_slot == -1) { // Special case, we are going to 'Export' the mesh to the
SERIAL_ECHOLNPGM("G29 I 999"); // host in a form it can be reconstructed on a different machine
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(ubl.z_values[x][y])) {
SERIAL_ECHOPAIR("M421 I ", x);
SERIAL_ECHOPAIR(" J ", y);
SERIAL_ECHOPGM(" Z ");
SERIAL_ECHO_F(ubl.z_values[x][y], 6);
SERIAL_ECHOPAIR(" ; X ", LOGICAL_X_POSITION(pgm_read_float(&ubl.mesh_index_to_xpos[x])));
SERIAL_ECHOPAIR(", Y ", LOGICAL_Y_POSITION(pgm_read_float(&ubl.mesh_index_to_ypos[y])));
SERIAL_EOL;
}
return;
}
const int16_t j = (UBL_LAST_EEPROM_INDEX - ubl.eeprom_start) / sizeof(ubl.z_values);
if (!WITHIN(storage_slot, 0, j - 1) || ubl.eeprom_start <= 0) {
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available for use.\n");
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", j - 1);
goto LEAVE;
}
ubl.store_mesh(storage_slot);
ubl.state.eeprom_storage_slot = storage_slot;
SERIAL_PROTOCOLLNPGM("Done.\n");
}
if (code_seen('O') || code_seen('M'))
ubl.display_map(code_has_value() ? code_value_int() : 0);
if (code_seen('Z')) {
if (code_has_value())
ubl.state.z_offset = code_value_float(); // do the simple case. Just lock in the specified value
else {
ubl.save_ubl_active_state_and_disable();
//measured_z = probe_pt(x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, ProbeDeployAndStow, g29_verbose_level);
ubl.has_control_of_lcd_panel = true; // Grab the LCD Hardware
measured_z = 1.5;
do_blocking_move_to_z(measured_z); // Get close to the bed, but leave some space so we don't damage anything
// The user is not going to be locking in a new Z-Offset very often so
// it won't be that painful to spin the Encoder Wheel for 1.5mm
lcd_implementation_clear();
lcd_z_offset_edit_setup(measured_z);
KEEPALIVE_STATE(PAUSED_FOR_USER);
do {
measured_z = lcd_z_offset_edit();
idle();
do_blocking_move_to_z(measured_z);
} while (!ubl_lcd_clicked());
ubl.has_control_of_lcd_panel = true; // There is a race condition for the Encoder Wheel getting clicked.
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune)
// or here. So, until we are done looking for a long Encoder Wheel Press,
// we need to take control of the panel
KEEPALIVE_STATE(IN_HANDLER);
lcd_return_to_status();
const millis_t nxt = millis() + 1500UL;
while (ubl_lcd_clicked()) { // debounce and watch for abort
idle();
if (ELAPSED(millis(), nxt)) {
SERIAL_PROTOCOLLNPGM("\nZ-Offset Adjustment Stopped.");
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
LCD_MESSAGEPGM("Z-Offset Stopped");
ubl.restore_ubl_active_state_and_leave();
goto LEAVE;
}
}
ubl.has_control_of_lcd_panel = false;
safe_delay(20); // We don't want any switch noise.
ubl.state.z_offset = measured_z;
lcd_implementation_clear();
ubl.restore_ubl_active_state_and_leave();
}
}
LEAVE:
lcd_reset_alert_level();
LCD_MESSAGEPGM("");
lcd_quick_feedback();
ubl.has_control_of_lcd_panel = false;
}
void unified_bed_leveling::find_mean_mesh_height() {
float sum = 0.0;
int n = 0;
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(ubl.z_values[x][y])) {
sum += ubl.z_values[x][y];
n++;
}
const float mean = sum / n;
//
// Now do the sumation of the squares of difference from mean
//
float sum_of_diff_squared = 0.0;
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(ubl.z_values[x][y]))
sum_of_diff_squared += sq(ubl.z_values[x][y] - mean);
SERIAL_ECHOLNPAIR("# of samples: ", n);
SERIAL_ECHOPGM("Mean Mesh Height: ");
SERIAL_ECHO_F(mean, 6);
SERIAL_EOL;
const float sigma = sqrt(sum_of_diff_squared / (n + 1));
SERIAL_ECHOPGM("Standard Deviation: ");
SERIAL_ECHO_F(sigma, 6);
SERIAL_EOL;
if (c_flag)
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(ubl.z_values[x][y]))
ubl.z_values[x][y] -= mean + ubl_constant;
}
void unified_bed_leveling::shift_mesh_height() {
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
if (!isnan(ubl.z_values[x][y]))
ubl.z_values[x][y] += ubl_constant;
}
/**
* Probe all invalidated locations of the mesh that can be reached by the probe.
* This attempts to fill in locations closest to the nozzle's start location first.
*/
void unified_bed_leveling::probe_entire_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map, const bool stow_probe, bool do_furthest) {
mesh_index_pair location;
ubl.has_control_of_lcd_panel = true;
ubl.save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
DEPLOY_PROBE();
do {
if (ubl_lcd_clicked()) {
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.\n");
lcd_quick_feedback();
STOW_PROBE();
while (ubl_lcd_clicked()) idle();
ubl.has_control_of_lcd_panel = false;
ubl.restore_ubl_active_state_and_leave();
safe_delay(50); // Debounce the Encoder wheel
return;
}
location = find_closest_mesh_point_of_type(INVALID, lx, ly, USE_PROBE_AS_REFERENCE, NULL, do_furthest);
if (location.x_index >= 0 && location.y_index >= 0) {
const float rawx = pgm_read_float(&ubl.mesh_index_to_xpos[location.x_index]),
rawy = pgm_read_float(&ubl.mesh_index_to_ypos[location.y_index]);
// TODO: Change to use `position_is_reachable` (for SCARA-compatibility)
if (!WITHIN(rawx, MIN_PROBE_X, MAX_PROBE_X) || !WITHIN(rawy, MIN_PROBE_Y, MAX_PROBE_Y)) {
SERIAL_ERROR_START;
SERIAL_ERRORLNPGM("Attempt to probe off the bed.");
ubl.has_control_of_lcd_panel = false;
goto LEAVE;
}
const float measured_z = probe_pt(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy), stow_probe, g29_verbose_level);
ubl.z_values[location.x_index][location.y_index] = measured_z;
}
if (do_ubl_mesh_map) ubl.display_map(map_type);
} while (location.x_index >= 0 && location.y_index >= 0);
LEAVE:
STOW_PROBE();
ubl.restore_ubl_active_state_and_leave();
do_blocking_move_to_xy(
constrain(lx - (X_PROBE_OFFSET_FROM_EXTRUDER), UBL_MESH_MIN_X, UBL_MESH_MAX_X),
constrain(ly - (Y_PROBE_OFFSET_FROM_EXTRUDER), UBL_MESH_MIN_Y, UBL_MESH_MAX_Y)
);
}
void unified_bed_leveling::tilt_mesh_based_on_3pts(const float &z1, const float &z2, const float &z3) {
matrix_3x3 rotation;
vector_3 v1 = vector_3( (UBL_PROBE_PT_1_X - UBL_PROBE_PT_2_X),
(UBL_PROBE_PT_1_Y - UBL_PROBE_PT_2_Y),
(z1 - z2) ),
v2 = vector_3( (UBL_PROBE_PT_3_X - UBL_PROBE_PT_2_X),
(UBL_PROBE_PT_3_Y - UBL_PROBE_PT_2_Y),
(z3 - z2) ),
normal = vector_3::cross(v1, v2);
normal = normal.get_normal();
/**
* This vector is normal to the tilted plane.
* However, we don't know its direction. We need it to point up. So if
* Z is negative, we need to invert the sign of all components of the vector
*/
if (normal.z < 0.0) {
normal.x = -normal.x;
normal.y = -normal.y;
normal.z = -normal.z;
}
rotation = matrix_3x3::create_look_at(vector_3(normal.x, normal.y, 1));
if (g29_verbose_level > 2) {
SERIAL_ECHOPGM("bed plane normal = [");
SERIAL_PROTOCOL_F(normal.x, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.y, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.z, 7);
SERIAL_ECHOLNPGM("]");
rotation.debug(PSTR("rotation matrix:"));
}
//
// All of 3 of these points should give us the same d constant
//
float t = normal.x * (UBL_PROBE_PT_1_X) + normal.y * (UBL_PROBE_PT_1_Y),
d = t + normal.z * z1;
if (g29_verbose_level>2) {
SERIAL_ECHOPGM("D constant: ");
SERIAL_PROTOCOL_F(d, 7);
SERIAL_ECHOLNPGM(" ");
}
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("d from 1st point: ");
SERIAL_ECHO_F(d, 6);
SERIAL_EOL;
t = normal.x * (UBL_PROBE_PT_2_X) + normal.y * (UBL_PROBE_PT_2_Y);
d = t + normal.z * z2;
SERIAL_ECHOPGM("d from 2nd point: ");
SERIAL_ECHO_F(d, 6);
SERIAL_EOL;
t = normal.x * (UBL_PROBE_PT_3_X) + normal.y * (UBL_PROBE_PT_3_Y);
d = t + normal.z * z3;
SERIAL_ECHOPGM("d from 3rd point: ");
SERIAL_ECHO_F(d, 6);
SERIAL_EOL;
}
#endif
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) {
float x_tmp = pgm_read_float(&ubl.mesh_index_to_xpos[i]),
y_tmp = pgm_read_float(&ubl.mesh_index_to_ypos[j]),
z_tmp = ubl.z_values[i][j];
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("before rotation = [");
SERIAL_PROTOCOL_F(x_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(y_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(z_tmp, 7);
SERIAL_ECHOPGM("] ---> ");
safe_delay(20);
}
#endif
apply_rotation_xyz(rotation, x_tmp, y_tmp, z_tmp);
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("after rotation = [");
SERIAL_PROTOCOL_F(x_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(y_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(z_tmp, 7);
SERIAL_ECHOLNPGM("]");
safe_delay(55);
}
#endif
ubl.z_values[i][j] += z_tmp - d;
}
}
}
float use_encoder_wheel_to_measure_point() {
while (ubl_lcd_clicked()) delay(50); // wait for user to release encoder wheel
delay(50); // debounce
KEEPALIVE_STATE(PAUSED_FOR_USER);
while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here!
idle();
if (ubl.encoder_diff) {
do_blocking_move_to_z(current_position[Z_AXIS] + 0.01 * float(ubl.encoder_diff));
ubl.encoder_diff = 0;
}
}
KEEPALIVE_STATE(IN_HANDLER);
return current_position[Z_AXIS];
}
static void say_and_take_a_measurement() {
SERIAL_PROTOCOLLNPGM(" and take a measurement.");
}
float measure_business_card_thickness(const float &in_height) {
ubl.has_control_of_lcd_panel = true;
ubl.save_ubl_active_state_and_disable(); // Disable bed level correction for probing
do_blocking_move_to_z(in_height);
do_blocking_move_to_xy(0.5 * (UBL_MESH_MAX_X - (UBL_MESH_MIN_X)), 0.5 * (UBL_MESH_MAX_Y - (UBL_MESH_MIN_Y)));
//, min(planner.max_feedrate_mm_s[X_AXIS], planner.max_feedrate_mm_s[Y_AXIS]) / 2.0);
stepper.synchronize();
SERIAL_PROTOCOLPGM("Place shim under nozzle.");
say_and_take_a_measurement();
const float z1 = use_encoder_wheel_to_measure_point();
do_blocking_move_to_z(current_position[Z_AXIS] + SIZE_OF_LITTLE_RAISE);
stepper.synchronize();
SERIAL_PROTOCOLPGM("Remove shim.");
say_and_take_a_measurement();
const float z2 = use_encoder_wheel_to_measure_point();
do_blocking_move_to_z(current_position[Z_AXIS] + SIZE_OF_LITTLE_RAISE);
if (g29_verbose_level > 1) {
SERIAL_PROTOCOLPGM("Business Card is: ");
SERIAL_PROTOCOL_F(abs(z1 - z2), 6);
SERIAL_PROTOCOLLNPGM("mm thick.");
}
ubl.has_control_of_lcd_panel = false;
ubl.restore_ubl_active_state_and_leave();
return abs(z1 - z2);
}
void manually_probe_remaining_mesh(const float &lx, const float &ly, const float &z_clearance, const float &card_thickness, const bool do_ubl_mesh_map) {
ubl.has_control_of_lcd_panel = true;
ubl.save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
do_blocking_move_to_z(z_clearance);
do_blocking_move_to_xy(lx, ly);
float last_x = -9999.99, last_y = -9999.99;
mesh_index_pair location;
do {
location = find_closest_mesh_point_of_type(INVALID, lx, ly, USE_NOZZLE_AS_REFERENCE, NULL, false);
// It doesn't matter if the probe can't reach the NAN location. This is a manual probe.
if (location.x_index < 0 && location.y_index < 0) continue;
const float rawx = pgm_read_float(&ubl.mesh_index_to_xpos[location.x_index]),
rawy = pgm_read_float(&ubl.mesh_index_to_ypos[location.y_index]);
// TODO: Change to use `position_is_reachable` (for SCARA-compatibility)
if (!WITHIN(rawx, UBL_MESH_MIN_X, UBL_MESH_MAX_X) || !WITHIN(rawy, UBL_MESH_MIN_Y, UBL_MESH_MAX_Y)) {
SERIAL_ERROR_START;
SERIAL_ERRORLNPGM("Attempt to probe off the bed.");
ubl.has_control_of_lcd_panel = false;
goto LEAVE;
}
const float xProbe = LOGICAL_X_POSITION(rawx),
yProbe = LOGICAL_Y_POSITION(rawy),
dx = xProbe - last_x,
dy = yProbe - last_y;
if (HYPOT(dx, dy) < BIG_RAISE_NOT_NEEDED)
do_blocking_move_to_z(current_position[Z_AXIS] + SIZE_OF_LITTLE_RAISE);
else
do_blocking_move_to_z(z_clearance);
do_blocking_move_to_xy(xProbe, yProbe);
last_x = xProbe;
last_y = yProbe;
KEEPALIVE_STATE(PAUSED_FOR_USER);
ubl.has_control_of_lcd_panel = true;
if (do_ubl_mesh_map) ubl.display_map(map_type); // show user where we're probing
while (ubl_lcd_clicked()) delay(50); // wait for user to release encoder wheel
delay(50); // debounce
while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here!
idle();
if (ubl.encoder_diff) {
do_blocking_move_to_z(current_position[Z_AXIS] + float(ubl.encoder_diff) / 100.0);
ubl.encoder_diff = 0;
}
}
const millis_t nxt = millis() + 1500L;
while (ubl_lcd_clicked()) { // debounce and watch for abort
idle();
if (ELAPSED(millis(), nxt)) {
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.");
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
lcd_quick_feedback();
while (ubl_lcd_clicked()) idle();
ubl.has_control_of_lcd_panel = false;
KEEPALIVE_STATE(IN_HANDLER);
ubl.restore_ubl_active_state_and_leave();
return;
}
}
ubl.z_values[location.x_index][location.y_index] = current_position[Z_AXIS] - card_thickness;
if (g29_verbose_level > 2) {
SERIAL_PROTOCOLPGM("Mesh Point Measured at: ");
SERIAL_PROTOCOL_F(ubl.z_values[location.x_index][location.y_index], 6);
SERIAL_EOL;
}
} while (location.x_index >= 0 && location.y_index >= 0);
if (do_ubl_mesh_map) ubl.display_map(map_type);
LEAVE:
ubl.restore_ubl_active_state_and_leave();
KEEPALIVE_STATE(IN_HANDLER);
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
do_blocking_move_to_xy(lx, ly);
}
static void say_ubl_name() {
SERIAL_PROTOCOLPGM("Unified Bed Leveling ");
}
static void report_ubl_state() {
say_ubl_name();
SERIAL_PROTOCOLPGM("System ");
if (!ubl.state.active) SERIAL_PROTOCOLPGM("de");
SERIAL_PROTOCOLLNPGM("activated.\n");
}
bool g29_parameter_parsing() {
bool err_flag = false;
LCD_MESSAGEPGM("Doing G29 UBL!");
lcd_quick_feedback();
ubl_constant = 0.0;
repetition_cnt = 0;
x_flag = code_seen('X') && code_has_value();
x_pos = x_flag ? code_value_float() : current_position[X_AXIS];
y_flag = code_seen('Y') && code_has_value();
y_pos = y_flag ? code_value_float() : current_position[Y_AXIS];
repeat_flag = code_seen('R');
if (repeat_flag) {
repetition_cnt = code_has_value() ? code_value_int() : (GRID_MAX_POINTS_X) * (GRID_MAX_POINTS_Y);
if (repetition_cnt < 1) {
SERIAL_PROTOCOLLNPGM("?(R)epetition count invalid (1+).\n");
return UBL_ERR;
}
}
g29_verbose_level = code_seen('V') ? code_value_int() : 0;
if (!WITHIN(g29_verbose_level, 0, 4)) {
SERIAL_PROTOCOLLNPGM("?(V)erbose level is implausible (0-4).\n");
err_flag = true;
}
if (code_seen('P')) {
phase_value = code_value_int();
if (!WITHIN(phase_value, 0, 6)) {
SERIAL_PROTOCOLLNPGM("?(P)hase value invalid (0-6).\n");
err_flag = true;
}
}
if (code_seen('J')) {
grid_size = code_has_value() ? code_value_int() : 3;
if (!WITHIN(grid_size, 2, 9)) {
SERIAL_PROTOCOLLNPGM("?Invalid grid size (J) specified (2-9).\n");
err_flag = true;
}
}
if (x_flag != y_flag) {
SERIAL_PROTOCOLLNPGM("Both X & Y locations must be specified.\n");
err_flag = true;
}
if (!WITHIN(RAW_X_POSITION(x_pos), X_MIN_POS, X_MAX_POS)) {
SERIAL_PROTOCOLLNPGM("Invalid X location specified.\n");
err_flag = true;
}
if (!WITHIN(RAW_Y_POSITION(y_pos), Y_MIN_POS, Y_MAX_POS)) {
SERIAL_PROTOCOLLNPGM("Invalid Y location specified.\n");
err_flag = true;
}
if (err_flag) return UBL_ERR;
// Activate or deactivate UBL
if (code_seen('A')) {
if (code_seen('D')) {
SERIAL_PROTOCOLLNPGM("?Can't activate and deactivate at the same time.\n");
return UBL_ERR;
}
ubl.state.active = 1;
report_ubl_state();
}
else if (code_seen('D')) {
ubl.state.active = 0;
report_ubl_state();
}
// Set global 'C' flag and its value
if ((c_flag = code_seen('C')))
ubl_constant = code_value_float();
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
if (code_seen('F') && code_has_value()) {
const float fh = code_value_float();
if (!WITHIN(fh, 0.0, 100.0)) {
SERIAL_PROTOCOLLNPGM("?(F)ade height for Bed Level Correction not plausible.\n");
return UBL_ERR;
}
set_z_fade_height(fh);
}
#endif
map_type = code_seen('O') && code_has_value() ? code_value_int() : 0;
if (!WITHIN(map_type, 0, 1)) {
SERIAL_PROTOCOLLNPGM("Invalid map type.\n");
return UBL_ERR;
}
if (code_seen('M')) { // Check if a map type was specified
map_type = code_has_value() ? code_value_int() : 0;
if (!WITHIN(map_type, 0, 1)) {
SERIAL_PROTOCOLLNPGM("Invalid map type.\n");
return UBL_ERR;
}
}
return UBL_OK;
}
/**
* This function goes away after G29 debug is complete. But for right now, it is a handy
* routine to dump binary data structures.
*/
/*
void dump(char * const str, const float &f) {
char *ptr;
SERIAL_PROTOCOL(str);
SERIAL_PROTOCOL_F(f, 8);
SERIAL_PROTOCOLPGM(" ");
ptr = (char*)&f;
for (uint8_t i = 0; i < 4; i++)
SERIAL_PROTOCOLPAIR(" ", hex_byte(*ptr++));
SERIAL_PROTOCOLPAIR(" isnan()=", isnan(f));
SERIAL_PROTOCOLPAIR(" isinf()=", isinf(f));
if (f == -INFINITY)
SERIAL_PROTOCOLPGM(" Minus Infinity detected.");
SERIAL_EOL;
}
//*/
static int ubl_state_at_invocation = 0,
ubl_state_recursion_chk = 0;
void unified_bed_leveling::save_ubl_active_state_and_disable() {
ubl_state_recursion_chk++;
if (ubl_state_recursion_chk != 1) {
SERIAL_ECHOLNPGM("save_ubl_active_state_and_disabled() called multiple times in a row.");
LCD_MESSAGEPGM("save_UBL_active() error");
lcd_quick_feedback();
return;
}
ubl_state_at_invocation = ubl.state.active;
ubl.state.active = 0;
}
void unified_bed_leveling::restore_ubl_active_state_and_leave() {
if (--ubl_state_recursion_chk) {
SERIAL_ECHOLNPGM("restore_ubl_active_state_and_leave() called too many times.");
LCD_MESSAGEPGM("restore_UBL_active() error");
lcd_quick_feedback();
return;
}
ubl.state.active = ubl_state_at_invocation;
}
/**
* Much of the 'What?' command can be eliminated. But until we are fully debugged, it is
* good to have the extra information. Soon... we prune this to just a few items
*/
void g29_what_command() {
const uint16_t k = E2END - ubl.eeprom_start;
say_ubl_name();
SERIAL_PROTOCOLPGM("System Version " UBL_VERSION " ");
if (ubl.state.active)
SERIAL_PROTOCOLCHAR('A');
else
SERIAL_PROTOCOLPGM("Ina");
SERIAL_PROTOCOLLNPGM("ctive.\n");
safe_delay(50);
if (ubl.state.eeprom_storage_slot == -1)
SERIAL_PROTOCOLPGM("No Mesh Loaded.");
else {
SERIAL_PROTOCOLPAIR("Mesh ", ubl.state.eeprom_storage_slot);
SERIAL_PROTOCOLPGM(" Loaded.");
}
SERIAL_EOL;
safe_delay(50);
SERIAL_PROTOCOLLNPAIR("UBL object count: ", (int)ubl_cnt);
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
SERIAL_PROTOCOLLNPAIR("planner.z_fade_height : ", planner.z_fade_height);
#endif
SERIAL_PROTOCOLPGM("zprobe_zoffset: ");
SERIAL_PROTOCOL_F(zprobe_zoffset, 7);
SERIAL_EOL;
SERIAL_PROTOCOLPGM("z_offset: ");
SERIAL_PROTOCOL_F(ubl.state.z_offset, 7);
SERIAL_EOL;
safe_delay(25);
SERIAL_PROTOCOLLNPAIR("ubl.eeprom_start=", hex_address((void*)ubl.eeprom_start));
SERIAL_PROTOCOLPGM("X-Axis Mesh Points at: ");
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(pgm_read_float(&ubl.mesh_index_to_xpos[i])), 1);
SERIAL_PROTOCOLPGM(" ");
safe_delay(50);
}
SERIAL_EOL;
SERIAL_PROTOCOLPGM("Y-Axis Mesh Points at: ");
for (uint8_t i = 0; i < GRID_MAX_POINTS_Y; i++) {
SERIAL_PROTOCOL_F(LOGICAL_Y_POSITION(pgm_read_float(&ubl.mesh_index_to_ypos[i])), 1);
SERIAL_PROTOCOLPGM(" ");
safe_delay(50);
}
SERIAL_EOL;
#if HAS_KILL
SERIAL_PROTOCOLPAIR("Kill pin on :", KILL_PIN);
SERIAL_PROTOCOLLNPAIR(" state:", READ(KILL_PIN));
#endif
SERIAL_EOL;
safe_delay(50);
SERIAL_PROTOCOLLNPAIR("ubl_state_at_invocation :", ubl_state_at_invocation);
SERIAL_EOL;
SERIAL_PROTOCOLLNPAIR("ubl_state_recursion_chk :", ubl_state_recursion_chk);
SERIAL_EOL;
safe_delay(50);
SERIAL_PROTOCOLLNPAIR("Free EEPROM space starts at: ", hex_address((void*)ubl.eeprom_start));
SERIAL_PROTOCOLLNPAIR("end of EEPROM : ", hex_address((void*)E2END));
safe_delay(50);
SERIAL_PROTOCOLLNPAIR("sizeof(ubl) : ", (int)sizeof(ubl));
SERIAL_EOL;
SERIAL_PROTOCOLLNPAIR("z_value[][] size: ", (int)sizeof(ubl.z_values));
SERIAL_EOL;
safe_delay(50);
SERIAL_PROTOCOLLNPAIR("EEPROM free for UBL: ", hex_address((void*)k));
safe_delay(50);
SERIAL_PROTOCOLPAIR("EEPROM can hold ", k / sizeof(ubl.z_values));
SERIAL_PROTOCOLLNPGM(" meshes.\n");
safe_delay(50);
SERIAL_PROTOCOLPAIR("sizeof(ubl.state) : ", (int)sizeof(ubl.state));
SERIAL_PROTOCOLPAIR("\nGRID_MAX_POINTS_X ", GRID_MAX_POINTS_X);
SERIAL_PROTOCOLPAIR("\nGRID_MAX_POINTS_Y ", GRID_MAX_POINTS_Y);
safe_delay(50);
SERIAL_PROTOCOLPAIR("\nUBL_MESH_MIN_X ", UBL_MESH_MIN_X);
SERIAL_PROTOCOLPAIR("\nUBL_MESH_MIN_Y ", UBL_MESH_MIN_Y);
safe_delay(50);
SERIAL_PROTOCOLPAIR("\nUBL_MESH_MAX_X ", UBL_MESH_MAX_X);
SERIAL_PROTOCOLPAIR("\nUBL_MESH_MAX_Y ", UBL_MESH_MAX_Y);
safe_delay(50);
SERIAL_PROTOCOLPGM("\nMESH_X_DIST ");
SERIAL_PROTOCOL_F(MESH_X_DIST, 6);
SERIAL_PROTOCOLPGM("\nMESH_Y_DIST ");
SERIAL_PROTOCOL_F(MESH_Y_DIST, 6);
SERIAL_EOL;
safe_delay(50);
if (!ubl.sanity_check()) {
say_ubl_name();
SERIAL_PROTOCOLLNPGM("sanity checks passed.");
}
}
/**
* When we are fully debugged, the EEPROM dump command will get deleted also. But
* right now, it is good to have the extra information. Soon... we prune this.
*/
void g29_eeprom_dump() {
unsigned char cccc;
uint16_t kkkk;
SERIAL_ECHO_START;
SERIAL_ECHOLNPGM("EEPROM Dump:");
for (uint16_t i = 0; i < E2END + 1; i += 16) {
if (!(i & 0x3)) idle();
print_hex_word(i);
SERIAL_ECHOPGM(": ");
for (uint16_t j = 0; j < 16; j++) {
kkkk = i + j;
eeprom_read_block(&cccc, (void *)kkkk, 1);
print_hex_byte(cccc);
SERIAL_ECHO(' ');
}
SERIAL_EOL;
}
SERIAL_EOL;
}
/**
* When we are fully debugged, this may go away. But there are some valid
* use cases for the users. So we can wait and see what to do with it.
*/
void g29_compare_current_mesh_to_stored_mesh() {
float tmp_z_values[GRID_MAX_POINTS_X][GRID_MAX_POINTS_Y];
if (!code_has_value()) {
SERIAL_PROTOCOLLNPGM("?Mesh # required.\n");
return;
}
storage_slot = code_value_int();
int16_t j = (UBL_LAST_EEPROM_INDEX - ubl.eeprom_start) / sizeof(tmp_z_values);
if (!WITHIN(storage_slot, 0, j - 1) || ubl.eeprom_start <= 0) {
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available for use.\n");
return;
}
j = UBL_LAST_EEPROM_INDEX - (storage_slot + 1) * sizeof(tmp_z_values);
eeprom_read_block((void *)&tmp_z_values, (void *)j, sizeof(tmp_z_values));
SERIAL_ECHOPAIR("Subtracting Mesh ", storage_slot);
SERIAL_PROTOCOLLNPAIR(" loaded from EEPROM address ", hex_address((void*)j)); // Soon, we can remove the extra clutter of printing
// the address in the EEPROM where the Mesh is stored.
for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++)
for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++)
ubl.z_values[x][y] -= tmp_z_values[x][y];
}
mesh_index_pair find_closest_mesh_point_of_type(const MeshPointType type, const float &lx, const float &ly, const bool probe_as_reference, unsigned int bits[16], const bool far_flag) {
mesh_index_pair out_mesh;
out_mesh.x_index = out_mesh.y_index = -1;
const float current_x = current_position[X_AXIS],
current_y = current_position[Y_AXIS];
// Get our reference position. Either the nozzle or probe location.
const float px = lx - (probe_as_reference == USE_PROBE_AS_REFERENCE ? X_PROBE_OFFSET_FROM_EXTRUDER : 0),
py = ly - (probe_as_reference == USE_PROBE_AS_REFERENCE ? Y_PROBE_OFFSET_FROM_EXTRUDER : 0);
float closest = far_flag ? -99999.99 : 99999.99;
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) {
if ( (type == INVALID && isnan(ubl.z_values[i][j])) // Check to see if this location holds the right thing
|| (type == REAL && !isnan(ubl.z_values[i][j]))
|| (type == SET_IN_BITMAP && is_bit_set(bits, i, j))
) {
// We only get here if we found a Mesh Point of the specified type
const float rawx = pgm_read_float(&ubl.mesh_index_to_xpos[i]), // Check if we can probe this mesh location
rawy = pgm_read_float(&ubl.mesh_index_to_ypos[j]);
// If using the probe as the reference there are some unreachable locations.
// Prune them from the list and ignore them till the next Phase (manual nozzle probing).
if (probe_as_reference == USE_PROBE_AS_REFERENCE &&
(!WITHIN(rawx, MIN_PROBE_X, MAX_PROBE_X) || !WITHIN(rawy, MIN_PROBE_Y, MAX_PROBE_Y))
) continue;
// Unreachable. Check if it's the closest location to the nozzle.
// Add in a weighting factor that considers the current location of the nozzle.
const float mx = LOGICAL_X_POSITION(rawx), // Check if we can probe this mesh location
my = LOGICAL_Y_POSITION(rawy);
float distance = HYPOT(px - mx, py - my) + HYPOT(current_x - mx, current_y - my) * 0.1;
/**
* If doing the far_flag action, we want to be as far as possible
* from the starting point and from any other probed points. We
* want the next point spread out and filling in any blank spaces
* in the mesh. So we add in some of the distance to every probed
* point we can find.
*/
if (far_flag) {
for (uint8_t k = 0; k < GRID_MAX_POINTS_X; k++) {
for (uint8_t l = 0; l < GRID_MAX_POINTS_Y; l++) {
if (!isnan(ubl.z_values[k][l])) {
distance += sq(i - k) * (MESH_X_DIST) * .05
+ sq(j - l) * (MESH_Y_DIST) * .05;
}
}
}
}
// if far_flag, look for farthest point
if (far_flag == (distance > closest) && distance != closest) {
closest = distance; // We found a closer/farther location with
out_mesh.x_index = i; // the specified type of mesh value.
out_mesh.y_index = j;
out_mesh.distance = closest;
}
}
} // for j
} // for i
return out_mesh;
}
void fine_tune_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map) {
if (!code_seen('R')) // fine_tune_mesh() is special. If no repetion count flag is specified
repetition_cnt = 1; // we know to do exactly one mesh location. Otherwise we use what the parser decided.
mesh_index_pair location;
uint16_t not_done[16];
int32_t round_off;
ubl.save_ubl_active_state_and_disable();
memset(not_done, 0xFF, sizeof(not_done));
LCD_MESSAGEPGM("Fine Tuning Mesh");
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
do_blocking_move_to_xy(lx, ly);
do {
location = find_closest_mesh_point_of_type(SET_IN_BITMAP, lx, ly, USE_NOZZLE_AS_REFERENCE, not_done, false);
// It doesn't matter if the probe can't reach this
// location. This is a manual edit of the Mesh Point.
if (location.x_index < 0 && location.y_index < 0) continue; // abort if we can't find any more points.
bit_clear(not_done, location.x_index, location.y_index); // Mark this location as 'adjusted' so we will find a
// different location the next time through the loop
const float rawx = pgm_read_float(&ubl.mesh_index_to_xpos[location.x_index]),
rawy = pgm_read_float(&ubl.mesh_index_to_ypos[location.y_index]);
// TODO: Change to use `position_is_reachable` (for SCARA-compatibility)
if (!WITHIN(rawx, UBL_MESH_MIN_X, UBL_MESH_MAX_X) || !WITHIN(rawy, UBL_MESH_MIN_Y, UBL_MESH_MAX_Y)) { // In theory, we don't need this check.
SERIAL_ERROR_START;
SERIAL_ERRORLNPGM("Attempt to edit off the bed."); // This really can't happen, but do the check for now
ubl.has_control_of_lcd_panel = false;
goto FINE_TUNE_EXIT;
}
float new_z = ubl.z_values[location.x_index][location.y_index];
if (!isnan(new_z)) { //can't fine tune a point that hasn't been probed
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE); // Move the nozzle to where we are going to edit
do_blocking_move_to_xy(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy));
round_off = (int32_t)(new_z * 1000.0); // we chop off the last digits just to be clean. We are rounding to the
new_z = float(round_off) / 1000.0;
KEEPALIVE_STATE(PAUSED_FOR_USER);
ubl.has_control_of_lcd_panel = true;
if (do_ubl_mesh_map) ubl.display_map(map_type); // show the user which point is being adjusted
lcd_implementation_clear();
lcd_mesh_edit_setup(new_z);
do {
new_z = lcd_mesh_edit();
idle();
} while (!ubl_lcd_clicked());
lcd_return_to_status();
// There is a race condition for the Encoder Wheel getting clicked.
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune)
// or here.
ubl.has_control_of_lcd_panel = true;
}
const millis_t nxt = millis() + 1500UL;
while (ubl_lcd_clicked()) { // debounce and watch for abort
idle();
if (ELAPSED(millis(), nxt)) {
lcd_return_to_status();
//SERIAL_PROTOCOLLNPGM("\nFine Tuning of Mesh Stopped.");
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
LCD_MESSAGEPGM("Mesh Editing Stopped");
while (ubl_lcd_clicked()) idle();
goto FINE_TUNE_EXIT;
}
}
safe_delay(20); // We don't want any switch noise.
ubl.z_values[location.x_index][location.y_index] = new_z;
lcd_implementation_clear();
} while (location.x_index >= 0 && location.y_index >= 0 && (--repetition_cnt>0));
FINE_TUNE_EXIT:
ubl.has_control_of_lcd_panel = false;
KEEPALIVE_STATE(IN_HANDLER);
if (do_ubl_mesh_map) ubl.display_map(map_type);
ubl.restore_ubl_active_state_and_leave();
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
do_blocking_move_to_xy(lx, ly);
LCD_MESSAGEPGM("Done Editing Mesh");
SERIAL_ECHOLNPGM("Done Editing Mesh");
}
/**
* 'Smart Fill': Scan from the outward edges of the mesh towards the center.
* If an invalid location is found, use the next two points (if valid) to
* calculate a 'reasonable' value for the unprobed mesh point.
*/
bool smart_fill_one(const uint8_t x, const uint8_t y, const int8_t xdir, const int8_t ydir) {
const int8_t x1 = x + xdir, x2 = x1 + xdir,
y1 = y + ydir, y2 = y1 + ydir;
// A NAN next to a pair of real values?
if (isnan(ubl.z_values[x][y]) && !isnan(ubl.z_values[x1][y1]) && !isnan(ubl.z_values[x2][y2])) {
if (ubl.z_values[x1][y1] < ubl.z_values[x2][y2]) // Angled downward?
ubl.z_values[x][y] = ubl.z_values[x1][y1]; // Use nearest (maybe a little too high.)
else
ubl.z_values[x][y] = 2.0 * ubl.z_values[x1][y1] - ubl.z_values[x2][y2]; // Angled upward...
return true;
}
return false;
}
typedef struct { uint8_t sx, ex, sy, ey; bool yfirst; } smart_fill_info;
void smart_fill_mesh() {
const smart_fill_info info[] = {
{ 0, GRID_MAX_POINTS_X, 0, GRID_MAX_POINTS_Y - 2, false }, // Bottom of the mesh looking up
{ 0, GRID_MAX_POINTS_X, GRID_MAX_POINTS_Y - 1, 0, false }, // Top of the mesh looking down
{ 0, GRID_MAX_POINTS_X - 2, 0, GRID_MAX_POINTS_Y, true }, // Left side of the mesh looking right
{ GRID_MAX_POINTS_X - 1, 0, 0, GRID_MAX_POINTS_Y, true } // Right side of the mesh looking left
};
for (uint8_t i = 0; i < COUNT(info); ++i) {
const smart_fill_info &f = info[i];
if (f.yfirst) {
const int8_t dir = f.ex > f.sx ? 1 : -1;
for (uint8_t y = f.sy; y != f.ey; ++y)
for (uint8_t x = f.sx; x != f.ex; x += dir)
if (smart_fill_one(x, y, dir, 0)) break;
}
else {
const int8_t dir = f.ey > f.sy ? 1 : -1;
for (uint8_t x = f.sx; x != f.ex; ++x)
for (uint8_t y = f.sy; y != f.ey; y += dir)
if (smart_fill_one(x, y, 0, dir)) break;
}
}
}
void unified_bed_leveling::tilt_mesh_based_on_probed_grid(const bool do_ubl_mesh_map) {
constexpr int16_t x_min = max(MIN_PROBE_X, UBL_MESH_MIN_X),
x_max = min(MAX_PROBE_X, UBL_MESH_MAX_X),
y_min = max(MIN_PROBE_Y, UBL_MESH_MIN_Y),
y_max = min(MAX_PROBE_Y, UBL_MESH_MAX_Y);
const float dx = float(x_max - x_min) / (grid_size - 1.0),
dy = float(y_max - y_min) / (grid_size - 1.0);
struct linear_fit_data lsf_results;
incremental_LSF_reset(&lsf_results);
bool zig_zag = false;
for (uint8_t ix = 0; ix < grid_size; ix++) {
const float x = float(x_min) + ix * dx;
for (int8_t iy = 0; iy < grid_size; iy++) {
const float y = float(y_min) + dy * (zig_zag ? grid_size - 1 - iy : iy);
float measured_z = probe_pt(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y), code_seen('E'), g29_verbose_level);
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_CHAR('(');
SERIAL_PROTOCOL_F(x, 7);
SERIAL_CHAR(',');
SERIAL_PROTOCOL_F(y, 7);
SERIAL_ECHOPGM(") logical: ");
SERIAL_CHAR('(');
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(x), 7);
SERIAL_CHAR(',');
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(y), 7);
SERIAL_ECHOPGM(") measured: ");
SERIAL_PROTOCOL_F(measured_z, 7);
SERIAL_ECHOPGM(" correction: ");
SERIAL_PROTOCOL_F(ubl.get_z_correction(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y)), 7);
}
#endif
measured_z -= ubl.get_z_correction(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y)) /* + zprobe_zoffset */ ;
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM(" final >>>---> ");
SERIAL_PROTOCOL_F(measured_z, 7);
SERIAL_EOL;
}
#endif
incremental_LSF(&lsf_results, x, y, measured_z);
}
zig_zag ^= true;
}
if (finish_incremental_LSF(&lsf_results)) {
SERIAL_ECHOPGM("Could not complete LSF!");
return;
}
if (g29_verbose_level > 3) {
SERIAL_ECHOPGM("LSF Results A=");
SERIAL_PROTOCOL_F(lsf_results.A, 7);
SERIAL_ECHOPGM(" B=");
SERIAL_PROTOCOL_F(lsf_results.B, 7);
SERIAL_ECHOPGM(" D=");
SERIAL_PROTOCOL_F(lsf_results.D, 7);
SERIAL_EOL;
}
vector_3 normal = vector_3(lsf_results.A, lsf_results.B, 1.0000).get_normal();
if (g29_verbose_level > 2) {
SERIAL_ECHOPGM("bed plane normal = [");
SERIAL_PROTOCOL_F(normal.x, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.y, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.z, 7);
SERIAL_ECHOLNPGM("]");
}
matrix_3x3 rotation = matrix_3x3::create_look_at(vector_3(lsf_results.A, lsf_results.B, 1));
for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) {
for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) {
float x_tmp = pgm_read_float(&ubl.mesh_index_to_xpos[i]),
y_tmp = pgm_read_float(&ubl.mesh_index_to_ypos[j]),
z_tmp = ubl.z_values[i][j];
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("before rotation = [");
SERIAL_PROTOCOL_F(x_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(y_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(z_tmp, 7);
SERIAL_ECHOPGM("] ---> ");
safe_delay(20);
}
#endif
apply_rotation_xyz(rotation, x_tmp, y_tmp, z_tmp);
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPGM("after rotation = [");
SERIAL_PROTOCOL_F(x_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(y_tmp, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(z_tmp, 7);
SERIAL_ECHOLNPGM("]");
safe_delay(55);
}
#endif
ubl.z_values[i][j] += z_tmp - lsf_results.D;
}
}
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
rotation.debug(PSTR("rotation matrix:"));
SERIAL_ECHOPGM("LSF Results A=");
SERIAL_PROTOCOL_F(lsf_results.A, 7);
SERIAL_ECHOPGM(" B=");
SERIAL_PROTOCOL_F(lsf_results.B, 7);
SERIAL_ECHOPGM(" D=");
SERIAL_PROTOCOL_F(lsf_results.D, 7);
SERIAL_EOL;
safe_delay(55);
SERIAL_ECHOPGM("bed plane normal = [");
SERIAL_PROTOCOL_F(normal.x, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.y, 7);
SERIAL_PROTOCOLCHAR(',');
SERIAL_PROTOCOL_F(normal.z, 7);
SERIAL_ECHOPGM("]\n");
SERIAL_EOL;
}
#endif
}
#endif // AUTO_BED_LEVELING_UBL