567941e341
Probing with the effector in the printing area, but an eccentric probe (e.g. allen key) outside it but still touching the bed gives meaninfull information for calibration. Since calibration is most accurate when probing as close to the towers as possible the testing was way to restrictive hence this fix. |
||
---|---|---|
.. | ||
Configuration.h | ||
Configuration_adv.h | ||
README.md |
Configuration for Kossel k800 XL
This example configuration is for a Kossel XL with a printable bed diameter of 280mm and a height of 380mm. It also has the auto bed leveling probe (with an endstop switch) and the heated bed activated.
Configuration
You might need (or want) to edit at least the following settings in Configuration.h
:
MANUAL_Z_HOME_POS
- The available height of your printing space. Auto Bed Leveling makes it less important to have the exact value.DELTA_PRINTABLE_RADIUS
- The printable radius is how far from the center the nozzle can reach.DEFAULT_AXIS_STEPS_PER_UNIT
- Steps-per-millimeter for the delta steppers, and for the extruder to optimize the amount of filament flow.
Fine tuning
- Increase
DELTA_RADIUS
if the model comes out convex (with a bulge in the middle) - Increase
DELTA_DIAGONAL_ROD
if the model comes out larger than expected
[http://reprap.org/wiki/PID_Tuning](PID Tuning)
DEFAULT_Kp
- The proportional termDEFAULT_Ki
- The integral termDEFAULT_Kd
- The derivative term
PSU Options
- The power supply is configured to 2 (to use a relay to switch 12V on and off)
- It is configured to be off by default