Commit graph

839 commits

Author SHA1 Message Date
Lenbok 0e8242180d Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback, updated for 2.0.x.

Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?

Chamber temperatures are not reported on the LCD in any way.

When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.

As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
2018-04-06 23:09:06 -05:00
Scott Lahteine adcb87f0db Z Endstop Servo => Z Probe Servo 2018-04-01 23:54:21 -05:00
Scott Lahteine dd2949922b Consolidate 3-point leveling point options 2018-03-19 04:12:20 -05:00
Scott Lahteine c6ff39cc14 Spacing cleanup 2018-03-17 16:49:08 -05:00
Scott Lahteine 14c03cb6f4
[2.0.x] Make MIN_PROBE_EDGE a general option (for electronic probes) (#10069)
Some probes don't work near the edges of the bed. This change promotes MIN_PROBE_EDGE to a general setting that applies to all probing functions.
2018-03-13 01:15:22 -05:00
Scott Lahteine 28f1276286
[2.0.x] Add Z_AFTER_PROBING option (#10058)
Some "fix-mounted" probes need manual stowing. And after probing some may prefer to raise or lower the nozzle. This restores an old option but tailors it to allow raise or lower as preferred.
2018-03-11 13:07:55 -05:00
Scott Lahteine 419d12ca1b Add UNKNOWN_Z_NO_RAISE option
With this option enabled, Z won't ever be raised until after `G28` has been completed, and it won't raise if Z becomes unknown. This is good for machines whose beds fall when Z is powered off.
2018-03-10 00:17:34 -06:00
Scott Lahteine a2a672449a Updated boot screen description 2018-03-03 20:04:17 -06:00
Scott Lahteine 4953fb1c88 Standardize encoder defaults 2018-02-24 22:34:45 -06:00
Scott Lahteine 5684beae90 Bring some configs up to speed 2018-02-24 21:56:27 -06:00
Scott Lahteine 2024775e07
Spanish (UTF8) Language (#9786)
From #7314 by @MrAmericanMike
2018-02-23 20:24:02 -06:00
Scott Lahteine b2cf253a13 Add RESTORE_LEVELING_AFTER_G28 option 2018-02-23 13:38:54 -06:00
Marcio Teixeira 13176dfe2f Merge remote-tracking branch 'origin/pr-lite-st7920-status' into pr-lite-st7920-status 2018-02-22 08:02:31 -07:00
Marcio Teixeira 716a22498f Changed temp type from uint8_t to int16_t
- Also deleted old implementation files which had been renamed.
2018-02-21 10:15:55 -07:00
Scott Lahteine 7d8c6b3f3c
Add 20x4 option for Sainsmart LCD (#9740) 2018-02-21 00:46:25 -06:00
Marcio Teixeira aada1e698f Removed unused configuration options. 2018-02-19 16:14:33 -07:00
Marcio Teixeira c7513eb032 Merge branch 'pr-lite-st7920-status' of github.com:marcio-ao/Marlin into pr-lite-st7920-status 2018-02-19 15:38:13 -07:00
Studiodyne d3ca82d8c2 Support for multiple filament runout sensors 2018-02-19 07:02:50 -06:00
Scott Lahteine ca55f2927a
Pulldown pin mode support (#9701)
Implemented for LPC1768.
2018-02-18 19:26:23 -06:00
Scott Lahteine 79272f98fc Proposed changes to ST7920 lightweight status screen 2018-02-18 02:47:31 -06:00
Marcio Teixeira 24eb275b99 Added a light-weight status screen for the ST7920
- The status screen uses the ST7920 character generator to greatly
  reduce SPI traffic and MCU load when updating the status screen.

- Has been tested with the RepRapDiscount Full Graphics Smart Controller
  but should work with any LCD that uses an ST7920 or fully compatible
  controller.
2018-02-18 02:29:45 -06:00
Scott Lahteine 08d685c97a Followup to 21e60fd 2018-02-16 02:09:17 -06:00
Roxy-3D 21e60fd3ed
Allow user to control Z-Height correction for off mesh movements (#9661) 2018-02-15 15:07:42 -06:00
Marcio Teixeira 4880ac6533 Added a light-weight status screen for the ST7920
- The status screen uses the ST7920 character generator to greatly
  reduce SPI traffic and MCU load when updating the status screen.

- Has been tested with the RepRapDiscount Full Graphics Smart Controller
  but should work with any LCD that uses an ST7920 or fully compatible
  controller.
2018-02-14 14:43:54 -07:00
Scott Lahteine 2ec65051fd Fix serial comment sp. 2018-02-13 22:40:56 -06:00
Scott Lahteine 2014d38e10 NEOPIXEL_BRIGHTNESS parity 2018-02-08 18:55:19 -06:00
Scott Lahteine b5e92f4f90
[2.0.x] Enable / disable PSU automatically (#9503) 2018-02-06 00:22:30 -06:00
Scott Lahteine 16739264d3 Add UltiController v2.1 support
Add compatibility with the original screen bord from Ultimaker 2 printer (UltiController v2.1 with the PG-2864ALBP I2C display)
2018-02-05 22:30:03 -06:00
Scott Lahteine 4925f60cff Add MALYAN_LCD to configs 2018-02-04 18:52:44 -06:00
Scott Lahteine 7d6c009104 Add thermistor 15 tuned for JGAurora A5 2018-01-22 01:27:11 -06:00
Scott Lahteine 348b454401 Probe bounds based on bed size 2018-01-22 01:05:11 -06:00
Scott Lahteine 58ed9901d7 Consistent NEOPIXEL_TYPE options 2018-01-21 17:19:38 -06:00
Scott Lahteine fa432508b0 Followup to Ender config 2018-01-15 06:00:21 -06:00
Scott Lahteine 048486390e Bring some configs up to date 2018-01-11 01:10:17 -06:00
Thomas Moore f7efac57b7 Multi-host support 2018-01-10 00:14:47 -06:00
GMagician 5295b4713d [2.0.x] add semitec 104NT-4 (#9119)
Table is very very similar to old 104-GT2 so I added only the name and recycled old ID
2018-01-09 16:53:12 -06:00
Scott Lahteine 0b4a46fa6c Bring configs up to date with 1.1.x 2017-12-30 23:28:53 -06:00
Thomas Moore f0a8a1a853 [2.0.x] Use NOZZLE_PARK_FEATURE for ADVANCED_PAUSE_FEATURE (#8866)
* Use NOZZLE_PARK_FEATURE for ADVANCED_PAUSE_FEATURE
2017-12-25 01:38:06 -06:00
Scott Lahteine 28fc8741d6 Reduce default jerk. XY by half. Z by 1/4 2017-12-24 19:54:11 -06:00
Even ea1a8d1223 add original RADDS LCD + Controller
adds setup for the original Radds Display+Controller+SD Card Reader PCB
http://doku.radds.org/dokumentation/lcd-display/
2017-12-24 19:00:23 -06:00
Dan Delaney b055d8c39c [2.0.x] Adding support for using the MKS_12864OLED with the SSD1306 controller (#8814)
* Adding support for using the MKS_12864OLED with the SSD1306 controller

* Update comment for correct controller type
2017-12-16 18:47:04 -06:00
Scott Lahteine 15d05748df Adding support for the Tronxy and Zonestar LCD 2017-12-15 19:13:52 -06:00
Scott Lahteine 69d49a2438 Shorter segments may be better 2017-12-09 06:29:14 -06:00
Scott Lahteine ae663a4198 PROBE_DOUBLE_TOUCH => MULTIPLE_PROBING 2017-12-07 16:44:13 -06:00
Richard Wackerbarth c1184552ac Change K1 to required option PID_K1 2017-12-05 19:59:59 -06:00
Scott Lahteine aa7efb96bf Bring configurations up to date 2017-12-02 21:50:51 -06:00
Scott Lahteine 0154e3480c New feature: BED_SKEW_CORRECTION 2017-12-01 19:39:49 -06:00
Scott Lahteine ef2531558c Add an option to segment leveled moves 2017-11-29 16:57:30 -06:00
Scott Lahteine 5926c9c97b Followup for MESH_EDIT_GFX_OVERLAY 2017-11-24 15:53:25 -06:00
Scott Lahteine 5ce7f23afa Config option G26_MESH_VALIDATION for all meshes 2017-11-23 21:43:23 -06:00