The extrusion speed was wrong due to a not high enough precision of
esteps to XY steps, therefore now the target float values are used to
calculate the ratio between XY movement and extrusion speed.
The e_speed_multiplier8 was replaced by an absolute multiplier called
abs_adv_steps_multiplier8, therefore one multiplication and bitshift can
be saved inside the stepper ISR. Due to this, also extruder_advance_k is
better suited inside the planner and not the stepper files any more.
.) long to int: Extruder stalls at 10kHz / 20kHz step limits with long.
.) Take the delta_adv_steps calculation out of the step_loops loop. Wasted calculation performance if done inside.
.) >> 2 replaced by 3: Is divide by 8. Reason: Timer 0 runs at 16/8=2MHz, Timer 1 at 16/64=0.25MHz. ==> 2/0.25=8.
The PrintrBoard Rev F utilizes a mcp4728 DAC to set motor current. Printrbot's implementation utilizes 2 new M-codes to set and write the DAC settings to the DAC EEPROM: `M909` (Read DAC) and `M910` (Write DAC). `M907` is re-used to set value, `M908` for direct control.
The Pins file for the RevF board is included.
Aim: Test probes in update_endstops only when activated
Changes:
Configurations
Add define for FIX_MOUNTED_PROBE to handle the situation where formerly ENDSTOPS_ONLY_FOR_HOMING had to be set, or lowering the nozzle below Z_PROBE_OFFSET_FROM_EXTRUDER could give an "endstop hit" message.
Add define for Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to indicate a common situation, that we have a probe but it is connected to an endstop pin
Add some comments
Shift some entries to have related things together.
Conditionals.h
We have a probe (HAS_Z_MIN_PROBE) if one of the pins is defined AND one of the probes is defined.
SanityCheck.h
Add some tests if the probe is connected and if we have defined a probe.
stepper.cpp
Changes to test the probe only when it is deployed (z_probe_is_active).
Test update_endstops() when the probe is deployed.
MarlinMain.cpp
a. set and reset z_probe_is_active in deploy_z_probe(), stow_z_probe() and dock_sled()
b. set and reset z_probe_is_active in the case a z-servo is moved to a defined position. The only remaining unhandled servo move is in M280 where we do not end in a defined position. If you want to handle a probe use M401/402
c. skip deploying/stowing when already deployed/stowed in the dedicated deploy/stow functions.
d. Handle the new FIX_MOUNTED_PROBE in parallel to a servo driven probe/endstop.
To do: In another PR. handle all probes in deploy/stow_z_probe.
Sort out SERVO_LEVELING vs. HAS_SERVO_ENDSTOPS.
(PR #138)
When the ISR does not finish in time, the timer will
wrap in the computation of the next interrupt time.
This hack replaces the correct (past) time with a time not far in the future.
Currently we use the probe exclusively as a device to find the build platform(bed).
For the currently supported setups this means, we use it as a additional min-endstop.
A triggered when not deployed probe disturbs the homing process for max-endstops.
Rename ENDSTOPPULLUP_ZPROBE to ENDSTOPPULLUP_ZMIN_PROBE
Rename Z_PROBE_ENDSTOP_INVERTING to Z_MIN_PROBE_ENDSTOP_INVERTING
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Rename DISABLE_Z_PROBE_ENDSTOP to DISABLE_Z_MIN_PROBE_ENDSTOP
Rename Z_PROBE_REPEATABILITY_TEST to Z_MIN_PROBE_REPEATABILITY_TEST
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Adjust comments accordingly
Remove Z_MAX check for the probe in update_endstops().
Using an delta related idea of @clefranc from #61,
extended to the general change for all setups.
Tested with Prusa i3, max-z-endstop and permanently triggered z-probe.
Worked for @clefranc's delta.