When both lowering and recovery are performed using the same "prepare_move_to_destination()" the extruder recovery feedrate ends up being ignored and, instead, is only capped by either the maximum e-speed or the time it takes to perform the z-lowering.
Performing the two moves separately from each other ensures a correct recovery feedrate.
add BLTouch-related messages in english and (rusty) french;
add missing endstops.h in ultralcd.cpp;
fix misc. compiler warnings;
fix lsf_reset - ZERO macro can't handle a pointer as it would only memset the size of the pointer, not the size of the entire struct
This is what I did yesterday:
- basicly gave the tests more comprehensive names; put all the
declarations at the top; got rid of the magic negative C-value (renamed
to P + A, O, T)
- "cos(RADIANS(180 + 30 * axis)) * (1 + circles * 0.1 * ((zig_zag) ? 1 :
-1)) * delta_calibration_radius" compiles wrong is zig_zag statement is
without brackets
- DELTA_TOWER_ANGLE_TRIM reset to 3 values (the calcs use the 3th value
to normalize will not compile otherwise)
-Wrote 3 dummies to keep EEPROM lenght the same
-Reset the configs to the 'original' with autocal + menu disabled (but
can be enabled of course)
The Configuration.h file entries for BL-Touch have been updated to:
```cpp
//#define BLTOUCH
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
//#define BLTOUCH_HEATERS_OFF // if defined the printer's heaters are
turned off during probe event
```
The electro-magnetic interference from the bed and nozzle are affecting
the BL-Touch repeatability for some users. This problem can be helped
by shutting down the heaters during the actual probe event and then
quickly turning them back on.
Because this code is messing with the heaters, it is written in a
paranoid manner. It only turns the heaters back on if everything is
EXACTLY as it expects things to be. The BL-Touch probe must have been
put into a deployed state less than 20 seconds prior, or the stow()
function will NOT turn the heaters on.
This code has been tested and works for both G28 and probing functions.
Giving a negative number of probe points disables the tower angle
correction calibration ('4point' instead of '7point' solution)
EEPROM version updated