in
G0 to G3 were previously acknowledged in the get_command method, causing
them to be possibly acknowledged before commands coming after them that
were acknowledged in process_commands.
This patch fixes this, moving the acknowledgement of G0 to G3 to the
process_commands method as well. These commands are therefore no
longer acknowledged when the enter the cmd_buffer but instead only
acknowledged when the enter the plan_buffer.
Guaranteeing that commands are acknowledged in the same order in which
they were received by the firmware allows host software to be able to
track the life cycle of commands and such a better management of the
firmware's serial buffers as well as better internal command processing
and response parsing without having to depend on throwing an epic
amount of regular expressions against each line received back from the
firmware.
FixesErikZalm/Marlin#1147
For the MORE_RAM option we need to buffer both the short and long
names, even though long names are sometimes redundant. Worst case, all
the names are max length. We can save some RAM by not storing these. We
could save more RAM by only storing the visible part of the long name.
For the MORE_RAM option we need to buffer both the short and long
names, even though long names are sometimes redundant. Worst case, all
the names are max length. We can save some RAM by not storing these. We
could save more RAM by only storing the visible part of the long name.
Tosh stepper drivers need to be driven slower, so the stepper code
was interleaved to separate the pin HIGH from the pin LOW. This adds
enough instructions to make it work, without needing nops.
Tosh stepper drivers need to be driven slower, so the stepper code
was interleaved to separate the pin HIGH from the pin LOW. This adds
enough instructions to make it work, without needing nops.
Here comes a compile-time operation to match the extruder symbols on the
info screen to the set number of extruders in configuration.h.
When only one extruder is selected, the "1" on the symbol will not be
displayed.
Added support to show the filament width on the status line of the
graphic LCD. The status will show for 5 sec and then switch over to
data. Status can be seen by clicking the button.
Changes to support displaying the real-time filament width and the
volume factor on a 20x4 LCD. The data is displayed on the 4th line.
First the status message is displayed for 5 seconds, and then the
filament data is displayed. The status message can be seen by
re-selecting the info screen in the menu.