Commit graph

101 commits

Author SHA1 Message Date
Ludy 1f93d2bcf7 Fix LCD compile error, etc. (#12472) 2018-11-18 20:39:49 -06:00
Marcio Teixeira c1e17037e5 Various fixes for MarlinUI and ExtUI (#12439) 2018-11-17 22:21:44 -06:00
Giuliano Zaro d3605cfc26 Don't start watching heaters when target is 0 (#12453) 2018-11-17 21:53:52 -06:00
Mateusz Krawczuk ca21ac6b9b Support two MAX6675 thermocouples (#8686) 2018-11-16 18:20:33 -06:00
Scott Lahteine d2bb53702a
Optimize target_extruder, ignore T with mixing (#12432)
* Optimize target_extruder, ignore T with mixing
* Give G-code Tn parity with tool_change
2018-11-14 17:33:04 -06:00
Scott Lahteine d82c350de7
Miscellaneous LCD code renaming, reordering (#12430)
* Move special characters to language.h
* Apply some naming standards
* Clean up menu item draw functions
* Rename some Temperature methods
* UI => ExtUI
2018-11-14 13:13:51 -06:00
Scott Lahteine a0c795b097
Encapsulate common display code in a singleton (#12395)
* Encapsulate common LCD code in a singleton
* Depend more UBL code on UBL_DEVEL_DEBUGGING
  - Since most users don't need the debugging on at all times, this helps reduce the default build size for UBL by over 2K, a little closer to fitting on 128K boards.
2018-11-11 12:16:24 -06:00
Scott Lahteine 6093df11dc
Allow G26 to use the active extruder (#12387)
* Make lcd_quick_feedback argument optional
* Add click_to_cancel option to wait_for_hotend/bed
* Have G26 use the active nozzle and wait_for_hotend/bed
* Use wait_for_release in UBL G29
* Add 'T' parameter to G26 for an initial tool-change
2018-11-10 18:07:38 -06:00
Ludy 5ba6607181 Fix keypad-related compile error (#12306) 2018-11-02 22:29:32 -05:00
Giuliano Zaro 323c088356 Restore LED light color after pid tuning (#12082) 2018-11-01 22:04:19 -05:00
Marcio Teixeira 71e19baf69 Fix kill => disable_all_heaters => print_job_timer.stop (#12146)
- Remove `print_job_timer.stop()` from `disable_all_heaters`
- Call `print_job_timer.stop()` for relevant `disable_all_heaters()`.
- Split up `kill()` for watchdog interrupt safety
2018-10-18 21:20:56 -05:00
Giuliano Zaro d43d4e4219 Refactor PRINTER_EVENT_LEDS, apply to M303 (#12038)
Co-Authored-By: Giuliano Zaro <gmagician@users.noreply.github.com>
2018-10-10 21:25:43 -05:00
Scott Lahteine d556dc1865
Fix and improve EEPROM storage (#12054)
* Clean up Temperature PID
* Improve EEPROM read/write/validate
* Group `SINGLENOZZLE` saved settings
* Group planner saved settings
* Group filament change saved settings
* Group skew saved settings
* Group `FWRETRACT` saved settings
2018-10-10 09:45:20 -05:00
InsanityAutomation 74cd6cb4fc Single nozzle filament change (#11994) 2018-10-07 17:06:14 -05:00
Scott Lahteine d6b0fbd771
Use uint8_t for all fan speeds (#12032) 2018-10-07 15:34:41 -05:00
Scott Lahteine 11ac75edcb
Use PGM_P for PSTR pointers (#11977) 2018-09-30 23:44:33 -05:00
Scott Lahteine d89d8fe852 Fix Busy State in temperature.cpp
Fix #11954
2018-09-29 17:03:35 -05:00
Scott Lahteine e4389f7d23
Standard methods to wait for heating (#11949) 2018-09-29 01:44:47 -05:00
Scott Lahteine 1718eff54a Code changes supporting up to 6 extruders 2018-09-16 22:32:53 -05:00
Scott Lahteine b220a825a7 Fix raw_filwidth_value error 2018-09-12 04:31:55 -05:00
AnHardt 530a13ab6c [2.0.x] SECURITYFIX missing max temp error when PID is used (#11717) 2018-09-05 01:41:45 -05:00
Dave Johnson c64199941e Compile only selected PIO environment (#11519) 2018-08-14 03:28:52 -05:00
Andy Shaw 624986d423 Ensure ADC conversion is complete before reading (#11336)
The current Marlin implementation relies on a timer interrupt to start the ADC conversion and read it. However in some circumstances the interrupt can be delayed resulting in insufficient time being available for the ADC conversion. This results in a bad reading and false temperature fluctuations. These changes make sure that the conversion is complete (by checking the ADC hardware via the HAL) before reading a value.

See: https://github.com/MarlinFirmware/Marlin/issues/11323
2018-07-26 03:59:19 -05:00
Scott Lahteine 22ebbc091f Tweak some SoftPWM code 2018-07-25 18:09:31 -05:00
etagle 1367df2875 Replace double with float, optimize calculation 2018-07-04 22:28:56 -05:00
Scott Lahteine 3fd1f32b73 Fix ADC key and chamber temp 2018-06-10 20:11:40 -05:00
Scott Lahteine 3701869e6c Add HAL_timer_start for AVR, use stepper timer to time pulses 2018-06-09 22:30:13 -05:00
Scott Lahteine 853a9056ac Long thermistor tables need special consideration 2018-05-28 06:28:34 -05:00
Scott Lahteine 1ce97f1f6d
Faster (bisect) search in thermistor tables (#10883) 2018-05-27 23:27:51 -05:00
Bob Kuhn d557c84a71 [2.0.x] Error for FAST_PWM_FAN with 32 bit CPU (#10798) 2018-05-20 11:37:55 -05:00
etagle 569df3fc0c Fix interrupt-based endstop detection
- Also implemented real endstop reading on interrupt.
2018-05-20 07:10:24 -05:00
etagle a11eb50a3e Refactor and optimize Stepper/Planner
Better encapsulation and considerably reduce stepper jitter
2018-05-20 06:23:58 -05:00
etagle 0566badcef Add memory barrier, optimal interrupt on-off
Disabling an ISR on ARM has 3 instructions of latency. A Memory barrier is REQUIRED to ensure proper and predictable disabling. Memory barriers are expensive, so avoid disabling if already disabled (See https://mcuoneclipse.com/2015/10/16/nvic-disabling-interrupts-on-arm-cortex-m-and-the-need-for-a-memory-barrier-instruction/)
2018-05-20 02:39:34 -05:00
Giuliano e1d9046efc [2.0.x] Temperature reading fix (#10774) 2018-05-19 15:39:36 -05:00
Scott Lahteine 99ecdf59af Smarter MIN, MAX, ABS macros
Use macros that explicitly avoid double-evaluation and can be used for any datatype, replacing `min`, `max`, `abs`, `fabs`, `labs`, and `FABS`.

Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-05-13 04:52:56 -05:00
Scott Lahteine 083ec9963e Tweaks to heater / lcd conditions 2018-05-13 04:52:56 -05:00
Scott Lahteine 8f8c6a9bc4
Move get_axis_position_mm to Planner (#10718) 2018-05-12 09:59:11 -05:00
Scott Lahteine a1062eec5b
Better handling of DELAY_NS and DELAY_US (#10716)
Co-Authored-By: ejtagle <ejtagle@hotmail.com>
2018-05-12 08:34:04 -05:00
Scott Lahteine f5aaa2d6c0 Fix some compiler warnings 2018-05-12 05:28:12 -05:00
Scott Lahteine 625035a9ce
Fix M301 access to lpq_len (#10714)
Co-Authored-By: Zwaubel
2018-05-12 02:13:40 -05:00
Scott Lahteine 325bbbc8c2
[2.0.x] Enable AD595 and AD8495 in concert (#10693)
* Allow both AD595 and AD8495 in concert
* General temperature code tweaks
2018-05-11 01:01:51 -05:00
Scott Lahteine 81b632c255 Additional temp-oriented improvements 2018-05-02 08:43:22 -05:00
nightdemonx e911635fb1 Add thermocouple with AD8495 support 2018-05-02 08:43:16 -05:00
Scott Lahteine 5ac226aa93 Further cleanup of inline delays 2018-04-27 19:22:22 -05:00
Chris Pepper 2242b98248 [LPC176x] Emergency Parser Feature (#10516) 2018-04-25 06:44:26 -05:00
Scott Lahteine 9789c1c719 Fix current_temperature_chamber compile error
Fix #10505
2018-04-24 07:55:58 -05:00
Eduardo José Tagle 0c428a66d9 Proper AVR preemptive interrupt handling (#10496)
Also simplify logic on all ARM-based interrupts. Now, it is REQUIRED to properly configure interrupt priority. USART should have highest priority, followed by Stepper, and then all others.
2018-04-23 22:05:07 -05:00
Scott Lahteine cb46cb8480
Add HAS_HEATED_BED conditional (#10495) 2018-04-23 17:13:01 -05:00
Lenbok 0e8242180d Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback, updated for 2.0.x.

Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?

Chamber temperatures are not reported on the LCD in any way.

When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.

As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
2018-04-06 23:09:06 -05:00
Scott Lahteine 1c36606886 Fix MSG_HEATING_FAILED_LCD_BED macro evaluation 2018-04-04 19:01:22 -05:00