* Make ExtUI respect MAXTEMP limits
- Temperatures are now clamped by MAXTEMP limits rather than arbitrary values.
* Speed up USB init, add status
- Speed up USB initialization
- Show status message if init failed
* Enable status messages for EXTENSIBLE_UI
* Adjust max limit to MAX_TEMP - 15
* Misc. tweaks to formatting, const, etc.
* Move special characters to language.h
* Apply some naming standards
* Clean up menu item draw functions
* Rename some Temperature methods
* UI => ExtUI
* Encapsulate common LCD code in a singleton
* Depend more UBL code on UBL_DEVEL_DEBUGGING
- Since most users don't need the debugging on at all times, this helps reduce the default build size for UBL by over 2K, a little closer to fitting on 128K boards.
* Make lcd_quick_feedback argument optional
* Add click_to_cancel option to wait_for_hotend/bed
* Have G26 use the active nozzle and wait_for_hotend/bed
* Use wait_for_release in UBL G29
* Add 'T' parameter to G26 for an initial tool-change
- Remove `print_job_timer.stop()` from `disable_all_heaters`
- Call `print_job_timer.stop()` for relevant `disable_all_heaters()`.
- Split up `kill()` for watchdog interrupt safety
* Clean up Temperature PID
* Improve EEPROM read/write/validate
* Group `SINGLENOZZLE` saved settings
* Group planner saved settings
* Group filament change saved settings
* Group skew saved settings
* Group `FWRETRACT` saved settings
The current Marlin implementation relies on a timer interrupt to start the ADC conversion and read it. However in some circumstances the interrupt can be delayed resulting in insufficient time being available for the ADC conversion. This results in a bad reading and false temperature fluctuations. These changes make sure that the conversion is complete (by checking the ADC hardware via the HAL) before reading a value.
See: https://github.com/MarlinFirmware/Marlin/issues/11323
Use macros that explicitly avoid double-evaluation and can be used for any datatype, replacing `min`, `max`, `abs`, `fabs`, `labs`, and `FABS`.
Co-Authored-By: ejtagle <ejtagle@hotmail.com>
Also simplify logic on all ARM-based interrupts. Now, it is REQUIRED to properly configure interrupt priority. USART should have highest priority, followed by Stepper, and then all others.
This is an initial cut for feedback, updated for 2.0.x.
Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?
Chamber temperatures are not reported on the LCD in any way.
When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.
As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
- Watchdog reset during SD Card initialization.
- Move `DebugMonitor` to `DebugMonitor_Due.cpp`.
- Since the watchdog is enabled on boot do extra resets during init.
- Have `thermalManager` do watchdog reset before its ISR starts to prevent reset.
- Ensure that timers are stopped before reprogramming them to address tone issues.
- Improve SAM3XE reset when reflashed through the native port.
Travis is having problems at: https://github.com/MarlinFirmware/Marlin/pull/8560
So... doing a direct commit to get things correct. Bugfix_v1.1.x does not have this bug. Nothing needs to be done to that branch.
include LPC1768 syntax for M42
couple more pin_t changes
consistency
change M42 to R, P format
Revert "change M42 to R, P format"
This reverts commit 01f12f579ec9ccc1bb9126e68d2c86449e9b7edf.