- Fix a bug in MAXxxxx thermocouple temp reporting.
- Add support for 3-wire HD44780.
- Add support for PCA9533 RGB driver.
- Add configuration examples for FlashForge CreatorPro.
* Make ExtUI respect MAXTEMP limits
- Temperatures are now clamped by MAXTEMP limits rather than arbitrary values.
* Speed up USB init, add status
- Speed up USB initialization
- Show status message if init failed
* Enable status messages for EXTENSIBLE_UI
* Adjust max limit to MAX_TEMP - 15
* Misc. tweaks to formatting, const, etc.
* Move special characters to language.h
* Apply some naming standards
* Clean up menu item draw functions
* Rename some Temperature methods
* UI => ExtUI
* Encapsulate common LCD code in a singleton
* Depend more UBL code on UBL_DEVEL_DEBUGGING
- Since most users don't need the debugging on at all times, this helps reduce the default build size for UBL by over 2K, a little closer to fitting on 128K boards.
* Make lcd_quick_feedback argument optional
* Add click_to_cancel option to wait_for_hotend/bed
* Have G26 use the active nozzle and wait_for_hotend/bed
* Use wait_for_release in UBL G29
* Add 'T' parameter to G26 for an initial tool-change
- Remove `print_job_timer.stop()` from `disable_all_heaters`
- Call `print_job_timer.stop()` for relevant `disable_all_heaters()`.
- Split up `kill()` for watchdog interrupt safety
* Clean up Temperature PID
* Improve EEPROM read/write/validate
* Group `SINGLENOZZLE` saved settings
* Group planner saved settings
* Group filament change saved settings
* Group skew saved settings
* Group `FWRETRACT` saved settings
The current Marlin implementation relies on a timer interrupt to start the ADC conversion and read it. However in some circumstances the interrupt can be delayed resulting in insufficient time being available for the ADC conversion. This results in a bad reading and false temperature fluctuations. These changes make sure that the conversion is complete (by checking the ADC hardware via the HAL) before reading a value.
See: https://github.com/MarlinFirmware/Marlin/issues/11323
Use macros that explicitly avoid double-evaluation and can be used for any datatype, replacing `min`, `max`, `abs`, `fabs`, `labs`, and `FABS`.
Co-Authored-By: ejtagle <ejtagle@hotmail.com>