Commit graph

1924 commits

Author SHA1 Message Date
Scott Lahteine 628391304f Merge pull request #6552 from thinkyhead/rc_more_ubl_cleanup
Further cleanup of UBL
2017-05-02 22:46:04 -05:00
Scott Lahteine 902fe76db9 Merge pull request #6556 from thinkyhead/rc_use_controller_fan
Implement USE_CONTROLLER_FAN as a feature
2017-05-02 22:43:26 -05:00
Scott Lahteine 7ba7474a73 Drop extra parens from address-of operator 2017-05-02 22:22:23 -05:00
Scott Lahteine fc857c5b78 Merge pull request #6549 from thinkyhead/rc_bltouch_refix
Fix BLTOUCH_HEATERS_OFF bug
2017-05-02 21:53:09 -05:00
Scott Lahteine 2c13922c46 Implement USE_CONTROLLER_FAN as a feature 2017-05-02 20:18:52 -05:00
Scott Lahteine 492bc536bf Modify debug methods to take PSTR 2017-05-02 17:53:40 -05:00
Brian ff5fed137f Fix BLTOUCH_HEATERS_OFF bug 2017-05-02 15:53:52 -05:00
LVD-AC da2abad636 Various cleanups of G33
- update comment section
- redefined P5 grid
- minor clean to probe radius routine
- updated EEPROM version to V37 according remark in #6517
2017-05-02 15:47:06 -05:00
Scott Lahteine e79b335367 Patches for leveling reactivation in G28 / M48 2017-05-01 17:38:57 -05:00
Scott Lahteine 7d5cd7e0d7 Tweak set_bed_leveling_enabled 2017-05-01 16:46:52 -05:00
Scott Lahteine ed81e9b3d3 Adjust leveling conditionals 2017-05-01 16:46:48 -05:00
Scott Lahteine a64e5659ce Clean up G26 external references, private vars 2017-05-01 15:17:52 -05:00
Scott Lahteine 2887c20788 Add a function to home all axes (i.e., gcode_G28) 2017-05-01 15:03:37 -05:00
Scott Lahteine 4f74c416a4 Patch for BLTOUCH_HEATERS_OFF 2017-05-01 11:13:40 -05:00
Scott Lahteine d814e468d2 Fix set_heaters_for_bltouch and usage
- Only call `set_heaters_for_bltouch` when actually deploying/stowing
- Clear `next_emi_protection` when re-enabling heaters
2017-05-01 02:27:52 -05:00
Brian 4e1448e75a Various fixes for compiler warnings
add BLTouch-related messages in english and (rusty) french;
add missing endstops.h in ultralcd.cpp;
fix misc. compiler warnings;
fix lsf_reset - ZERO macro can't handle a pointer as it would only memset the size of the pointer, not the size of the entire struct
2017-05-01 02:12:40 -05:00
Scott Lahteine 671a44b8aa Merge pull request #6410 from teemuatlut/LVD-Delta
Delta auto-calibration updates
2017-04-30 16:39:51 -05:00
LVD-AC cafc48dff8 little oops 2017-04-30 22:17:49 +03:00
LVD-AC 471a321624 leaner code for probe routine 2017-04-30 19:15:16 +03:00
LVD-AC 585c00a728 Proposed changes
This is what I did yesterday:

- basicly gave the tests more comprehensive names; put all the
declarations at the top; got rid of the magic negative C-value (renamed
to P + A, O, T)

- "cos(RADIANS(180 + 30 * axis)) * (1 + circles * 0.1 * ((zig_zag) ? 1 :
-1)) * delta_calibration_radius" compiles wrong is zig_zag statement is
without brackets

- DELTA_TOWER_ANGLE_TRIM reset to 3 values (the calcs use the 3th value
to normalize will not compile otherwise)

-Wrote 3 dummies to keep EEPROM lenght the same

-Reset the configs to the 'original' with autocal + menu disabled (but
can be enabled of course)
2017-04-29 18:53:14 +03:00
Scott Lahteine 29fa241617 Initial patches to G33 2017-04-29 15:29:49 +03:00
Scott Lahteine 42f4c53254 Starting on G33 rewrite 2017-04-29 15:29:49 +03:00
Scott Lahteine 1a111180de Clean up set_heaters_for_bltouch 2017-04-28 18:32:39 -05:00
Scott Lahteine 0a8e09c723 Clean up excess whitespace, comment formatting 2017-04-28 18:32:38 -05:00
Scott Lahteine 8020069371 Apply coding standards for indentation 2017-04-28 15:43:06 -05:00
LVD-AC 4ea8d0f89b Solved "The Travis CI build failed " 2017-04-28 19:55:21 +03:00
LVD-AC 7a6a1ef583 M666 normalize positive values to <=0
M666

+ tower radians absolute value
2017-04-28 18:05:24 +03:00
Roxy-3D 4075b95519 Allow BL-Touch users to control heaters during probe event (#6485)
The Configuration.h file entries for BL-Touch have been updated to:
```cpp
//#define BLTOUCH
//#define BLTOUCH_DELAY 375      // (ms) Enable and increase if needed
//#define BLTOUCH_HEATERS_OFF // if defined the printer's heaters are
turned off during probe event
```
2017-04-28 09:19:55 -05:00
Roxy-3D 6e8ecb908a Shut down heaters during BL-Touch probe event
The electro-magnetic interference from the bed and nozzle are affecting
the BL-Touch repeatability for some users.   This problem can be helped
by shutting down the heaters during the actual probe event and then
quickly turning them back on.

Because this code is messing with the heaters, it is written in a
paranoid manner.  It only turns the heaters back on if everything is
EXACTLY as it expects things to be.  The BL-Touch probe must have been
put into a deployed state less than 20 seconds prior, or the stow()
function will NOT turn the heaters on.

This code has been tested and works for both G28 and probing functions.
2017-04-27 18:52:58 -05:00
LVD-AC d8102aeca8 Cn negative : no tower angle calibration
Giving a negative number of probe points disables the tower angle
correction calibration ('4point' instead of '7point' solution)

EEPROM version updated
2017-04-27 21:13:07 +03:00
LVD-AC a9bc1d30cc z_offset change
Avoids to have to recalibrate the delta_height after a z_offset change
2017-04-26 21:57:11 +03:00
Scott Lahteine 5bdb0b567d Cosmetic patches 2017-04-26 06:24:23 -05:00
Scott Lahteine a699967ec8 Merge pull request #6443 from thinkyhead/rc_interrupt_fastio
Patch fastio.h with Timer 2 interrupt support
2017-04-24 20:09:41 -05:00
Scott Lahteine 2823bf0874 Update fastio.h with special handling for Timer 2 2017-04-24 16:58:22 -05:00
Scott Lahteine fd535e111a Fix up XYZ_CONSTS_FROM_CONFIG macro 2017-04-24 14:05:11 -05:00
LVD-AC dcf30a69d6 Allowing #define DELTA_TOWER_ANGLE_TRIM[C_AXIS]
More consistent with M665 where C-value is allowed as well, then
normalized
2017-04-23 14:51:24 +03:00
Brian f41fb2b635 Numerous UBL-related changes:
* relocated ubl state to config. store:
 * removed a number of ubl state variables and padding which were largely unused - saved 58 bytes of both SRAM and EEPROM;
 * modified ubl sanity_check - no longer checks removed state variables that were otherwise unused, where checking didn't seem to accomplish anything, ultimately;
 * removed pre_initialized state, saving 64 bytes of SRAM;
 * removed automatic saving of UBL state after UBL activation/deactivation;
* consolidated multiple GRID_MAX_POINTS_X/Y to 'Global Leveling' section of EEPROM;
* minor update to G29 Sx notes/instructions;
* renamed mesh load and save parameter to 'slot' from 'm' for clarity;
2017-04-22 18:44:39 -05:00
Scott Lahteine 830851df13 Spend some SRAM to optimize bilinear leveling 2017-04-22 16:19:31 -05:00
Scott Lahteine 091179d960 bed_level_grid => z_values (also *_virt array) 2017-04-22 16:19:31 -05:00
Scott Lahteine 23cdbbb2d3 Add a method to refresh bilinear bed level after a change 2017-04-22 16:19:30 -05:00
Scott Lahteine ccda63c473 Drop the accessor form for LCD value editing 2017-04-22 16:19:30 -05:00
Scott Lahteine 10da175be5 Fix a pair of compiler complaints 2017-04-22 16:19:30 -05:00
Scott Lahteine ff0018e287 Format hex values as uppercase 2017-04-21 21:42:41 -05:00
teemuatlut 244f67590e Delta probe height bug solved 2017-04-22 02:23:56 +03:00
LVD-AC 004928148c Tower angles
Adding '7-point' tower angle correction calibration
2017-04-21 12:48:45 +03:00
LVD-AC 76ec7a0f80 Adding upto 7*7 probe grids
- adding Cn 5, 6 and 7
2017-04-21 11:58:39 +03:00
LVD-AC d4f593d200 Delete 'expert level'
and getting rid off verbose level 3 and configuration_adv settings
2017-04-21 11:58:39 +03:00
LVD-AC 13c8493878 M665 rework and related issues (all delta's)
- Making M665 compatible with repetier (see
http://reprap.org/wiki/G_code#M665:_Set_delta_configuration)

- M665 B also sets the radius for manual calibration menu

- Converting tower ajustment definitions to arrays - tower angle
corrections compatible with Esher 3D wizzard

- Only tower angles need to be adjustable with M665 and stored to EEPROM
- tower radius and diag rod can be adjusted in the FW only with #define
2017-04-21 11:58:39 +03:00
Scott Lahteine ee46ce1743 Add and apply interrupt helper macros 2017-04-20 16:04:29 -05:00
Scott Lahteine 6131c62499 General cleanup 2017-04-20 16:04:29 -05:00